1. Introduction

Thank you for choosing the FDIK Panda U6 Diesel Air Parking Heater. This all-in-one portable heater is designed to provide efficient and reliable heating for various applications, including camping, warehouses, and trucks. This manual provides essential information for the safe and effective setup, operation, and maintenance of your heater.

FDIK Panda U6 All-in-one Parking Heater, front view
A front view of the FDIK Panda U6 All-in-one Parking Heater, showcasing its compact design and integrated control panel.

2. Safety Information

Please read all safety instructions carefully before operating the heater. Failure to follow these instructions may result in property damage, personal injury, or death.

  • Exhaust Gas Warning: Exhaust gas contains poisonous gas (carbon monoxide). During operation, the exhaust port MUST be mounted outdoors to ensure proper ventilation and prevent carbon monoxide poisoning.
  • Fuel Handling: Use only diesel fuel. Ensure proper handling and storage of fuel to prevent leaks and fire hazards.
  • Electrical Connections: Ensure all electrical connections are secure and correctly wired according to the specified voltage (12V, 24V, or 220V). Incorrect wiring can cause electrical shock or fire.
  • Ventilation: Always ensure adequate ventilation in the area where the heater is operating, especially if used indoors with the appropriate adapter.
  • Clearances: Maintain sufficient clearance around the heater to prevent obstruction of air intake and exhaust, and to avoid overheating nearby objects.
  • Stability: Place the heater on a stable, level surface to prevent tipping.
  • Safety Features: The FDIK Panda U6 is designed with safety in mind, featuring excellent sealing performance, contact stability, vibration resistance, and temperature resistance. However, these features do not replace the need for careful operation.
FDIK Panda U6 heater safety features and power connections
This image illustrates the safety protection features of the FDIK Panda U6, including sealing performance, contact stability, vibration resistance, and temperature resistance. It also shows the 12V power cord and the adapter for indoor heating.

3. Package Contents

Upon unpacking, please verify that all the following items are included in your package:

  • FDIK Panda U6 Heater Unit
  • LCD Controller x 1
  • Remote Controller x 1
  • Buckle x 4
  • Silencer x 1
  • Wind Head x 1
  • Tubing x 1
  • Hot Air Duct x 1
  • 12V Power Cord
  • Adapter for Indoor Heating
FDIK Panda U6 All-in-one Parking Heater with included accessories
This image displays the main FDIK Panda U6 heater unit along with its complete set of accessories, including two controllers, buckles, silencer, wind head, tubing, hot air duct, 12V power cord, and an indoor heating adapter.
FDIK Panda U6 heater dimensions and accessory box contents
This image provides the dimensions of the FDIK Panda U6 heater (370mm x 240mm x 290mm) and lists the contents of the accessory box, including controllers, buckles, silencer, wind head, tubing, and hot air duct.

4. Specifications

FeatureSpecification
ModelPanda U6
Power8000W
Voltage12V, 24V, 220V (Universal Voltage)
Fuel TypeDiesel
Item TypeHeating & Fans
External Testing CertificationCE
Item Weight10kg
Dimensions (L x W x H)370mm x 240mm x 290mm
Noise Level<55 decibels
Chassis MaterialADC12 Aluminum Integrated Chassis
Side Baffle MaterialPA6 + G30 Eco-friendly
Controller FeaturesBluetooth, Time Setting, Temperature Protection, Power Protection, Overheating Protection, Temperature Mode
Exploded view of FDIK Panda U6 heater showing internal components and chassis materials
An exploded view of the FDIK Panda U6 heater, highlighting its ADC12 aluminum integrated chassis and PA6 + G30 eco-friendly side baffle, indicating robust construction.
Internal view of FDIK Panda U6 heater showing fuel-efficient design
An internal diagram of the FDIK U-series heater, emphasizing its fuel-efficient design with a high-quality silent oil pump, a 2.0KG heater body, and a motherboard with precise program instructions for optimal performance.
FDIK Panda U6 heater internal components and performance features
An illustration of the FDIK Panda U6 heater's internal components, highlighting universal voltage compatibility, overheating protection, temperature mode, sound output below 55 decibels, and features that reduce fuel consumption.

5. Setup and Installation

Proper installation is crucial for the safe and efficient operation of your heater. Follow these guidelines:

5.1 Exhaust System

  • The exhaust port must always be mounted outdoors to safely vent poisonous exhaust gases.
  • The muffler should be mounted horizontally, as shown in the diagram, with the small drainage hole facing downwards to prevent water accumulation.
Installation example of FDIK Panda U6 heater exhaust system
This image demonstrates proper installation of the FDIK Panda U6 heater's exhaust system, showing the exhaust port mounted outdoors and the muffler positioned horizontally with the small hole facing down.

5.2 Power Connection

  • For 12V/24V applications (e.g., trucks, RVs), use the provided 12V power cord and connect it to a compatible power source.
  • For 220V indoor heating, use the included adapter for indoor heating. Ensure the power outlet is grounded and capable of handling the heater's wattage.
FDIK Panda U6 heater connected with indoor heating adapter
This image shows the FDIK Panda U6 heater connected with the included adapter, demonstrating its setup for indoor heating applications.

6. Operation

The FDIK Panda U6 heater can be controlled via its integrated LCD panel or the remote controller.

6.1 LCD Controller

The LCD controller provides comprehensive control and monitoring capabilities:

  • Power On/Off: Use the designated buttons to turn the heater on or off.
  • Temperature Setting: Adjust the desired temperature using the control interface. The heater will automatically regulate its output to maintain the set temperature.
  • Time Setting: Program the heater to operate for specific durations or at scheduled times.
  • Monitoring: The display shows current temperature, operating status, and any active protection modes (e.g., temperature protection, power protection).
  • Bluetooth: The controller supports Bluetooth connectivity for enhanced control options (refer to specific app instructions if applicable).
Close-up of FDIK Panda U6 LCD controller with features
A detailed view of the FDIK Panda U6 LCD controller, showcasing its features including Bluetooth connectivity, time setting, temperature protection, and power protection.

6.2 Remote Controller

The remote controller allows for convenient operation from a distance, typically for basic power on/off and temperature adjustments.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your FDIK Panda U6 heater.

  • Cleaning: Periodically clean the exterior of the heater and ensure that air intake and exhaust vents are free from dust, debris, or obstructions.
  • Fuel System: Check the fuel lines and connections for any signs of leaks or damage. Ensure the fuel filter (if accessible) is clean.
  • Electrical Connections: Inspect all electrical wiring and connections for tightness and signs of corrosion or damage.
  • General Inspection: Regularly check the heater for any unusual noises, vibrations, or smells during operation. Address any issues promptly.

8. Troubleshooting (Fault Codes)

If your heater encounters an issue, it may display a fault code on the LCD controller. Refer to the table below for common fault codes, their causes, and recommended workarounds.

Fault CodeCauseWorkaround
E-2Supply voltage range issueNormal range: 24V (18-32V), 12V (9-16V). Check whether the battery or generator is normal and whether the fuse is aging.
E-3Glow plug failureCheck whether the ignition plug connector is loose or the wire is short-circuited to the housing. Check whether the ignition plug is damaged.
E-4Oil pump failureCheck whether the oil pump connecting wires and connectors are damaged, loose, oxidized, short-circuited, or open-circuited.
E-5High temperature alarm (intake air>50°C; housing>230°C)Check whether the heating air duct is unobstructed. Check whether the fan is operating normally. Check whether the temperature sensor is normal.
E-6Fan failureCheck if the impeller is stuck. Check whether the connection plug is loose. Is the gap between the magnet on the wind wheel and the Hall sensor on the controller too large? Is the circuit short-circuited or open-circuited? Is the motor leaking electricity?
E-7Connection failedDetection harness.
E-8Lack of oilCheck whether there is oil shortage, oil solidification at low temperature, oil line blockage, oil pump stuck, etc. Check whether the oxygen inlet and exhaust pipes are unobstructed. Check whether the shell temperature sensor is in full contact with the shell and whether the pressure spring is firm.
E-9Sensor failureCheck whether the temperature sensor connection line or connector is damaged or loose, and whether the sensor is damaged.
E-10Startup failureThe casing temperature is too high and the casing cannot cool down after 3 minutes of startup. A lot of white smoke comes out of the exhaust gas. There is a small amount of white smoke or no smoke in the exhaust gas. a. Check whether the ignition plug is damaged. b. Is the gap between the inner wind wheels too large?

9. User Tips

  • Accessing Parameters: The LCD controller allows access to various settings and parameters. Explore the menu options to customize your heating experience, including time settings and temperature limits. Refer to the controller's interface for detailed navigation.
  • Quiet Operation: The FDIK U-series is designed for low noise operation, thanks to its silent oil pump, heavy heater body, dynamically balanced fan, and high-quality muffler. This makes it suitable for environments where noise reduction is important.
  • Fuel Efficiency: The heater features a high-quality silent oil pump and precise program instructions on its motherboard, contributing to its fuel-efficient performance.
FDIK Panda U6 heater demonstrating low noise operation
The image highlights the design elements contributing to the FDIK U-series' low noise operation: a silent oil pump, a heater body weighing over 2.0KG to reduce combustion noise, a fan undergoing strict dynamic balance testing, and a high-quality muffler.

10. Warranty and Support

For any warranty claims, technical support, or further inquiries, please contact FDIK customer service. Keep your purchase receipt as proof of purchase.

© 2024 FDIK. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.