Jonsbo N6

Contents

Jonsbo N6 NAS PC Case Instruction Manual

Model: N6

1. Product Overview

The Jonsbo N6 is the latest member of the Jonsbo NAS chassis series, designed to serve as both a NAS (Network Attached Storage) host box and a versatile desktop computer case. It boasts a large storage capacity, compatibility with full-size graphics cards, and robust cooling system support. The chassis supports MATX motherboards and features an upper and lower compartment structure for flexible configurations. Its overall appearance adopts a low-key and elegant style, with multiple mesh ventilation holes and a narrow wooden decorative panel embedded in the front panel for aesthetic appeal. The three-speed fan speed controller on the front panel allows for real-time heat dissipation adjustments. N6 also provides dual power slots for advanced DIY users, offering crucial flexibility for diverse needs.

Jonsbo N6 NAS Case on a desk setup.

The Jonsbo N6 NAS Case, designed for ITX/M-ATX systems, shown in a typical desktop environment.

Jonsbo N6 NAS Case with hard drive bays open.

The Jonsbo N6 NAS Case with its front hard drive bays open, revealing the storage capacity.

A video demonstrating the features, internal layout, and assembly options of the Jonsbo N6 NAS Case, including power supply configurations, hard drive installation, and cooling solutions.

2. Specifications

FeatureSpecification
Product ModelN6
ColorBlack
Case Size (W*D*H)305mm * 353mm * 318mm (including 6mm high footrest)
Material0.7mm + 1.0mm Steel Plate
Hard Disk Space9 x 2.5" SSD or 9 x 3.5" HDD
Motherboard SupportITX / M-ATX
PCI Expansion Slots4
Front Ports1 x USB 3.2 Gen2 Type-C, 1 x USB 3.0, 1 x AUDIO + 1 x MIC (2-in-1)
Power Supply SupportATX (max 220mm) / SFX (max 100mm) - supports dual power mode
Max CPU Cooler Height160mm
Max GPU Length320mm (275mm with water cooling, 305mm with 25mm front fan)
Cooling System (Fan Options)Front: 2 x 120mm or 2 x 140mm
Rear: 1 x 120mm
Left Side: 2 x 120mm
Right Side: 2 x 120mm
Hard Drive Compartment: 2 x 120mm (standard)
Fan Speed Controller3-port / 3-speed (standard)
Water Cooling Support240mm
Case Weight7.5kg (net weight)
Chassis TypeDesktops, Mid Tower
Dust FiltersREAR
RGB SupportNO RGB
Size comparison of Jonsbo NAS chassis models.

A visual comparison of different Jonsbo NAS chassis models, including the N6, showing their relative dimensions.

Jonsbo N6 chassis dimensions.

Diagram showing the dimensions of the Jonsbo N6 chassis: 305mm (W) * 353mm (D) * 318mm (H).

Summary of Jonsbo N6 features.

Icons summarizing features: MATX version (within 24.5*24.5CM), Three speed fan speed controller, Dual power support, 240 water cooling support, Standard 12025 fans * 2, Long graphics card support.

3. Setup and Installation

3.1 Motherboard Installation

The Jonsbo N6 chassis supports both ITX and M-ATX motherboards. Ensure your motherboard's dimensions are within 24.5cm x 24.5cm for M-ATX boards.

Jonsbo N6 motherboard support for ITX/M-ATX.

Internal space for ITX/M-ATX motherboards.

3.2 Power Supply Installation

The N6 chassis offers flexible power supply installation options, including dual power modes for advanced configurations.

3.2.1 Upper Power Mode

This mode supports ATX power supplies with a CPU heatsink height of up to 65mm, or SFX power supplies with a CPU heatsink height of up to 75mm. A power support bracket is included to ensure stable operation.

Upper power supply mode for Jonsbo N6.

Diagram showing the upper power supply mode, supporting ATX PSUs with CPU heatsink height ≤ 65mm and SFX PSUs with CPU heatsink height ≤ 75mm. Comes with power support bracket.

3.2.2 Lower Power Mode

For this mode, follow these steps:

  1. Use the included rear window fan bracket to block the upper power supply position.
  2. Use the included bottom mounted power bracket to achieve bottom mounted installation of an SFX power supply.
  3. The original rear window 12cm fan can be moved to the upper compartment position for installation.

This mode supports a CPU heatsink height of up to 160mm.

Lower power supply installation mode for Jonsbo N6.

Instructions for 'Lower power mode': 1. Use rear window fan bracket to block upper power supply position. 2. Use bottom mounted power bracket for bottom mounted installation of SFX power supply. 3. Original rear window 12cm fan can be moved to upper compartment. Supports CPU heatsink height ≤ 160mm.

3.2.3 Dual Power Mode

Dual power installation can be achieved using the included power bracket. This supports independent power supply for hard drive compartments, ensuring stable operation of multiple hard drives. Note that a dual power synchronous starting cable/starter needs to be purchased separately.

Dual power supply modes for Jonsbo N6 NAS Case.

Diagram illustrating two dual power installation modes. Both modes support independent power supply for hard drive compartments to ensure stable operation of multiple hard drives. Requires separate purchase of dual power synchronous starting cable/starter.

3.3 Hard Drive Installation

The N6 chassis supports up to 9 x 2.5" SSDs or 9 x 3.5" HDDs. It features a server-grade 10μm gold-plated SAS hot-swappable backplane for easy data exchange and long service life. New metal hard drive brackets with reserved handles are provided for easier installation.

Jonsbo N6 with 9 hot-swappable 3.5-inch hard drives.

The Jonsbo N6 with 9 hot-swappable 3.5-inch hard drives installed in the front bays, emphasizing its large storage capacity.

Server-level hot swappable backplane for Jonsbo N6.

Image of the server-grade 10 μm gold-plated SAS hot swappable interface, designed for long service life.

3.3.1 Backplane Power Requirements

The backplane supports SATA/SAS 9-bit hard drive interfaces. It has 4 sets of power supply interfaces (2 x PATA, 2 x SATA). For ordinary household-grade mechanical hard drives (SATA/SAS) with a starting current of 1A-2.5A, it can be powered by connecting 3 sets of power supplies. For enterprise-grade hard drives, due to higher starting current, it is recommended to fully plug in 4 sets of power supplies. Always refer to the parameters of each brand for the actual power/hard drive requirements. Insufficient current may cause the hard drive to fail to start. Only one power interface (ATX-4Pin or SATA power lines) is allowed to be inserted into the backplane; multiple power plugs on a set of power lines are not allowed to be inserted into the backplane at the same time.

SATA/SAS backplane wiring diagram and power requirements.

Detailed diagram of the SATA/SAS backplane with power supply heads (SATA D-type, PATA D-type) and front hard drive indicator light socket. Important notes: Supports SATA/SAS 9-bit hard drive interface. Has 4 sets of power supply interfaces (PATA * 2 + SATA * 2). Starting current for household grade mechanical hard drives (SATA/SAS) is 1A-2.5A, powered by 3 sets of power supplies. Enterprise grade drives require full plug-in to 4 sets of power supplies. Only one power interface (ATX-4Pin or SATA power lines) allowed per backplane; multiple power plugs not allowed simultaneously.

3.4 Cooling System Installation

The N6 chassis provides extensive cooling support for optimal performance.

3.4.1 Fan Positions

  • Front panel: 2 x 120mm or 2 x 140mm fans
  • Rear panel: 1 x 120mm fan
  • Left side: 2 x 120mm fans
  • Right side: 2 x 120mm fans
  • Hard drive compartment: 2 x 120mm fans (standard)

The motherboard compartment fan is not standard and can be assembled according to specific cooling requirements.

Jonsbo N6 heat dissipation fan positions.

Diagram detailing fan positions: Front panel 120mm * 2 or 140mm * 2, Rear panel 120mm * 1, Left side 120mm * 2, Right side 120mm * 2, Hard drive compartment 120mm * 2 (standard). Notes that motherboard compartment fan is not standard and can be assembled based on cooling needs.

3.4.2 Standard Fans

The chassis includes two standard 12025 double ball fans at the bottom, operating at 1750 (± 10%) RPM, specifically for auxiliary hard disk cooling.

Standard bottom fans for Jonsbo N6 hard disk cooling.

Image showing two standard 12025 double ball fans at the bottom, operating at 1750 (± 10%) RPM for auxiliary hard disk cooling.

3.4.3 Water Cooling

The front panel supports a 240mm water cooling radiator.

Jonsbo N6 with 240mm water cooling installed.

Image showing the internal layout with a 240mm water cooling radiator installed on the front panel.

3.5 Graphics Card Installation

The N6 chassis can accommodate graphics cards up to 320mm in length. Please note the following length restrictions based on other installed components:

  • When installing a 25mm thick fan on the front panel, the maximum graphics card length is 305mm.
  • If water cooling is installed, the maximum graphics card length is 275mm.
Graphics card length support in Jonsbo N6.

Diagram showing support for graphics cards up to 320mm. Notes: 305mm when installing a 25mm thick fan on the front panel; total thickness of front panel installation is 55mm; 275mm when water-cooled.

4. Operating Instructions

4.1 Front Panel Interfaces

The front panel provides convenient access to various ports and controls:

  • 1 x USB 3.2 Gen2 Type-C (10Gbps) interface to reduce transmission latency.
  • 1 x USB 3.0 port.
  • 1 x Audio port and 1 x Microphone port (combined 2-in-1).
  • Fan speed control switch (3rd gear).
Front panel interfaces of Jonsbo N6 NAS Case.

Diagram showing the front panel interfaces: USB 3.0 (5Gbps), USB 3.2 Gen2 Type-C (10Gbps), fan speed control switch (3rd gear), and audio ports.

4.2 Fan Speed Control

The standard three-speed fan speed regulator on the front panel allows for free and quick adjustment of fan speed to optimize cooling performance and noise levels.

Fan speed regulator switch on Jonsbo N6.

Close-up of the standard three-speed fan speed regulator switch (1, 2, 3) on the front panel for free and quick adjustment of fan speed.

4.3 Hot-Swappable Hard Drives

The front 9-bit 3.5-inch hard drive bays support hot-plugging for convenient data exchange without needing to power down the system.

5. Maintenance

5.1 Dust Filters

The chassis includes dust filters at the rear to help prevent dust accumulation inside the system. Regularly clean these filters to maintain optimal airflow and cooling efficiency.

5.2 General Cleaning

Periodically clean the exterior of the chassis with a soft, dry cloth. For internal cleaning, ensure the system is powered off and unplugged. Use compressed air to remove dust from fans and components. Avoid using liquid cleaners directly on electronic components.

5.3 Hard Drive Heat Dissipation

To ensure optimal heat dissipation for hard drives, it is recommended to maintain at least a 5mm gap between drives, according to different thicknesses, to enhance ventilation efficiency.

Hard drive heat dissipation design in Jonsbo N6.

Diagram illustrating the new space design for hard drive heat dissipation, recommending at least 5mm gap between drives. Features standard server-level hot plug SATA/SAS backplane for long service life.

6. Troubleshooting

If you encounter any issues with your Jonsbo N6 PC Case, please consider the following general troubleshooting steps:

  • No Power: Ensure all power cables are securely connected to the power supply, motherboard, and wall outlet. Verify the power supply switch is in the 'ON' position.
  • Overheating: Check that all fans are spinning correctly and are free from obstructions. Clean any dust filters or internal components. Ensure proper airflow within the case.
  • Hard Drive Issues: If a hard drive is not detected or is unstable, verify its power and data cables are securely connected. Ensure sufficient power is supplied to the backplane as per the specifications (3 or 4 sets of power supplies depending on drive type).
  • Component Fit: Double-check component dimensions against the specifications, especially for CPU coolers, GPUs, and power supplies, to ensure they fit within the case's limits.

For persistent issues, consult the component manufacturers' manuals or seek professional technical support.

7. User Tips

While specific user tips from reviews or Q&A were not provided, here are some general recommendations for optimizing your Jonsbo N6 NAS PC Case experience:

  • Cable Management: Utilize the internal space and tie-down points for effective cable management. This improves airflow, reduces clutter, and makes future maintenance easier.
  • Fan Configuration: Experiment with different fan configurations and the 3-speed controller to find the optimal balance between cooling performance and noise level for your specific hardware setup.
  • Hard Drive Spacing: When installing multiple hard drives, try to leave a small gap (at least 5mm) between them if possible, especially for 3.5" HDDs, to aid in heat dissipation.
  • Regular Dusting: Make it a habit to regularly clean the dust filters and internal components to prevent dust buildup, which can lead to higher temperatures and reduced component lifespan.

8. Warranty and Support