1. Product Overview
The Mileseey TR256I, TR20, and TR20 Pro are advanced thermal imaging cameras designed for various applications including industrial inspections, automotive maintenance, electrical inspections, water leak detection, and home inspections. These devices provide real-time temperature display, customizable image effects, and high-precision temperature measurement.
1.1. Components and Features
The TR20 and TR20 Pro models feature a handheld design with an integrated display, while the TR256I is a compact, phone-attachable thermal imager.

Mileseey TR256i thermal imager with phone display and accessories.

TR256i connected to Android phone and laptop via extension cable.

Photo and video output examples from the thermal imager.

Customizable image effects and measurement features on phone app.

Real-time temperature display with hot, center, and cold spot tracking.

Wide applications of the thermal imager (industrial, auto, electrical, water leakage, home inspection).
1.2. TR20/TR20 Pro Handheld Thermal Imager Components

TR20/TR20 Pro unboxing contents: camera, carrying case, USB cable, quick user guide, cleaning cloth, pass card.

TR20 Pro features: 320x240 IR pixels, 480x640 display, 50Hz refresh, video recording, PC analysis, 50°x50° wide field of view.

Built-in IR and Visual Camera (TR20 Pro), showing Thermal, Visual, PIP, Fusion modes.
1.3. TR256I Mobile Thermal Imager Components

TR256i Thermal Imaging Camera: 256x192 resolution, -15°C to 600°C, regional temperature measurement, Type-C OTG, 20g, aluminum alloy shell, video/photo.
1.4. Unboxing Video (TR20/TR20 Pro)
Unboxing and initial look at the Mileseey TR20/TR20 Pro thermal imaging camera.
2. Setup and Operation
2.1. Display Icons Overview

Display icons on the thermal imager screen showing battery level, center temperature, max/min temperature on bar, temperature bar, crosshairs, date & time, detection distance, temperature range indicator, and emissivity.
- Battery Level Indicator: Shows current battery charge.
- Center Temperature: Temperature at the center point.
- Max. Temperature on the Bar: Highest temperature detected within the current view.
- Min. Temperature on the Bar: Lowest temperature detected within the current view.
- Temperature Bar: Visual scale of temperature range.
- Center Point/Crosshairs: Indicates the central measurement point.
- Max. Temperature Point: Indicates the hottest spot.
- Date & Time: Current date and time.
- Detection Distance: Set measurement distance.
- Temperature Range Indicator: Shows the active temperature measurement range.
- Emissivity: Emissivity value for the target object.
2.2. Power On/Off
To power on or off the device, press and hold the power button (usually marked with a circle and a vertical line or 'SET' button on some models).
2.3. Settings Menu
Press the SET button to enter the setting menu. Use the Up/Down navigation buttons to select items and adjust values. Press the SET button again to confirm each setting. To return to the previous page, press the power button.
Settings Options:
- Emissivity (0.01~0.99): Adjust for accurate temperature readings based on the material being inspected.
- Distance (0.3m~3m): Set the measurement distance.
- Ambient Temperature: Calibrate for ambient conditions.
- Temperature Range: Select between Normal (-20°C~150°C) and High (100°C~550°C) modes.
- Temperature Units: Switch between Celsius (°C) and Fahrenheit (°F).
- Palette: Choose from eight color palettes (White Hot, Black Hot, Iron, Rainbow, Blend, Red Hot, Blue Hot, Green Hot) for different visual representations of thermal data.
- HI/LO Alarm: Configure high/low temperature alarms, including buzzer on/off and temperature thresholds.
- Display: Customize display elements such as Hotspot/Coldspot indicators, Centre Spot, Palette, Measure Parameter, Clock, and Battery.
- Display Brightness: Adjust screen brightness (Low/Mid/High).
- Date & Time: Set the current date and time. Use Left/Right to select items and Up/Down to adjust values.
- Correction: Perform imaging calibration.
- USB Mode: Select between USB Disk (for data transfer) and USB Camera (for live streaming).
- Snap Mode: Configure photo capture settings (Alarm Triggered, Time Triggered, Time Set).
- Auto Power Off: Set automatic shutdown time (5min/10min/30min/Off).
- Language: Select the device language.
- Format Disk: Format the internal memory.
- Factory Reset: Restore default settings.
- Device Info: View device information.
2.4. Image Mode (TR20 Pro Only)
For TR20 Pro models, press the SET button to enter the Image Mode menu. Use the Up/Down buttons to select between Digital, Fusion Rate, Fusion Offset, PIP (Picture-in-Picture), and Thermal modes. Press SET again to confirm your selection.
2.5. Temperature Width Adjustment
Temperature width allows users to adjust the temperature range to highlight thermal imaging effects more prominently. Press the SET button to enter the Temperature Width setting. Press SET again to select whether to adjust the maximum value, minimum value, or both simultaneously. Use the Up/Down buttons to adjust the values. A visible lock icon indicates that the value can be adjusted.
2.6. Regional Temperature Detection
Press the SET button to enter the Region mode. Press and hold the navigation buttons to expand or narrow the measurement box. In this mode, the device will only measure the temperature within the defined box.
2.7. Taking Pictures and Videos
- Pictures: Short-press the trigger button to capture a still image.
- Videos: Long-press the trigger button to start recording. Long-press again to stop recording.
*Pictures and videos are automatically saved to the device's memory.
2.8. Viewing and Deleting Pictures/Videos
Press the Memory button (usually marked with a photo icon) to enter the picture and video memory. Press the SET button to enter a folder, file, picture preview, or video playback.
- View Pictures: In the full-screen preview interface, use the Left/Right navigation buttons to switch between pictures.
- Delete Pictures: Press Left/Right in the file page or press the SET button in the full-screen preview interface to delete selected pictures or clear the entire folder.
- Video Playback: Press the SET button in the preview page to play or pause videos.
- Delete Videos: Press Left/Right in the file page or in the preview page to delete selected videos or clear the entire folder.
2.9. Shortcut Buttons (Home Interface)
In the home interface, the navigation buttons provide quick access to functions:
- Right Navigation Button: Turn on/off the display.
- Left Navigation Button: Imaging calibration.
- Up/Down Navigation Buttons: Switch image mode.
3. Product Specifications
| Feature | Specification |
|---|---|
| Model | TR20/TR20 Pro |
| IR Resolution | 320*240 |
| FOV (Field of View) | 50°× 37.2° |
| NETD (Noise Equivalent Temperature Difference) | < 40mK |
| Frame Rate | 50Hz |
| Digital Camera Resolution | 2MP (TR20 Pro Only) |
| Display | 2.8" LCD Display, 480*640 |
| Temperature Range | -20°C to 550°C |
| Measuring Accuracy | ±2% |
| Memory | 8GB Internal EMMC |
| Distance Range | 0.3m~3m |
| Battery Capacity | 5,000mAh |
| Operating Temperature | -10°C to 50°C |
| Storage Temperature | -20°C to 60°C |
| Charging Port | USB-C |
| Dimensions | 224*91.6*76mm |
*All data are measured and provided by the MILESEEY Lab; actual use may vary slightly depending on specific circumstances.
3.1. TR256I Specific Specifications
| Feature | Specification |
|---|---|
| Resolution | 256x192 |
| Temperature Range | -15°C to 600°C |
| Weight | 20g |
| Shell Material | Aluminum Alloy |
| Interface | Type-C OTG |

TR256i high precision temperature measurement up to ±2°C, with a wider range of -15°C to 600°C.
4. Maintenance
- Cleaning: Please use a wet cloth or mild soap detergent to clean the outer casing of the product. DO NOT use abrasives, isopropyl alcohol, or solvents to clean the product.
- Storage: Store the device within the specified storage temperature range of -20°C to 60°C.
- Lens Protection: While the device comes with a carrying bag, it is recommended to ensure the lenses are protected when not in use, as there might not be a dedicated lens cover.
5. Safety Instructions
- For accurate measurement results and your personal safety, always follow the instructions in this user manual. Damage resulting from not following instructions may void the warranty.
- Avoid using the product in flammable, explosive, steamy, or corrosive environments.
- Stop using the product immediately if it is damaged or modified to prevent inaccurate measurement results or potential hazards.
- Always set the correct emissivity value for the inspected object to obtain accurate temperature readouts.
- It is recommended to wait for 2 minutes after powering on the device for the internal temperature to stabilize before taking measurements.
- The internal temperature of the product may rise during charging, which can lead to inaccurate temperature measurements. It is NOT recommended to use the product for measurements during charging or immediately after charging.
6. Troubleshooting
If you encounter any issues with your Mileseey thermal imager, please refer to the relevant sections in this manual for operational guidance. Ensure all settings, such as emissivity and distance, are correctly configured for your measurement environment. If problems persist, contact customer support.
7. User Tips
- Emissivity Setting: Pay attention to the emissivity setting. It's crucial for accurate temperature readings, especially when measuring different materials. If you're unsure, a quick online search for common material emissivity values can be helpful.
- Distance Limitation: The device's distance range is manually set from 0.3m to 3m. Be aware of this limitation for optimal performance.
- Lens Protection: Although a carrying bag is included, consider additional lens protection if you frequently transport the device or work in dusty environments.
- Language Settings: While the device may not always include all languages (e.g., Russian), the interface is generally intuitive. Refer to the 'Settings' section for language options.
- Warm-up Time: Allow the device to warm up for at least 2 minutes after powering on to ensure internal temperature stability and more accurate readings.
8. Warranty and Support
8.1. Copyrights
Product specifications are subject to change without prior notice. All rights for final interpretation are reserved by Mileseey Technology Co., Ltd. All trademarks, product images, and technical parameters belong to Mileseey Technology Co., Ltd. All rights reserved.
8.2. Product Disposal
This product should not be discarded with regular domestic waste. Instead, it must be disposed of in accordance with local regulations and guidelines specific to your country/region. Waste batteries must be disposed of at designated collection stations for proper handling.
8.3. Contact Us
Shenzhen Mileseey Technology Co., Ltd.
Address: No.3601 Block A, Tanglang Town Plaza West, Fuguang Community, Taoyuan Street, Nanshan District, Shenzhen, China
Website: www.mileseeytools.com
Email: service@mileseey.com