ANENJI ANL-4200T-24L-W-PRO, ANL-6200T-48L-W-PRO, ANL-11000T-48L-W-PRO

Aninerel Hybrid Solar Inverter User Manual

Models: ANL-4200T-24L-W-PRO, ANL-6200T-48L-W-PRO, ANL-11000T-48L-W-PRO

Brand: ANENJI

Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your Aninerel Hybrid Solar Inverter. This series of inverters (ANL-4200T-24L-W-PRO, ANL-6200T-48L-W-PRO, ANL-11000T-48L-W-PRO) features a pure sine wave output, built-in MPPT solar charger, and is designed for both on-grid and off-grid applications. Key features include dual output for smart load management, lithium battery activation, compatibility with LiFePO4 batteries via RS485, and remote monitoring via WiFi. Please read this manual thoroughly before installation and operation to ensure safe and efficient use.

1. Installation and Setup

1.1 Product Overview

Familiarize yourself with the inverter's components and connection points.

Detailed product overview showing front, side, and bottom views of the Aninerel Hybrid Solar Inverter with labeled ports.
Figure 1: Detailed Product Overview with Labeled Ports (LCD display, Function buttons, RGB Indicator, Power on/off switch, Built-in WiFi, RS485 communication port, Grounding, PV input, AC input, Main output, Second output, Battery input).

1.2 Application Diagram

The following diagram illustrates a typical application setup for the hybrid solar inverter, integrating solar panels, utility grid, generator, battery, and various household loads.

Application Diagram showing solar panels, utility grid, generator, battery, and household appliances connected to the inverter.
Figure 2: Application Diagram for Hybrid Solar Inverter System.

1.3 PV Connection

When connecting PV modules, ensure proper selection based on the inverter's specifications to prevent damage and ensure optimal performance.

PV Connection diagram showing solar panels connected to the inverter and a house, with parameters for PV module selection.
Figure 3: PV Connection Diagram and Selection Parameters.

Important PV Module Selection Parameters:

  1. Open circuit Voltage (Voc) of PV modules must not exceed the maximum PV array open circuit voltage of the inverter.
  2. Open circuit Voltage (Voc) of PV modules should be higher than the minimum battery voltage.

1.4 Battery Connection

Connect batteries according to the specified voltage and polarity. Incorrect connection can lead to severe damage or injury.

Battery Connection diagram for a 48V model, showing four 12V batteries in series, with warnings about high battery voltage.
Figure 4: Battery Connection Diagram (48V Model Example).

WARNING: Shock Hazard! Installation must be performed with care due to high battery voltage in series.

  • Do not place anything between the flat part of the inverter terminal. Otherwise, overheating may occur.
  • Do not apply anti-oxidant substance on the terminals before terminals are connected tightly.
  • Before making the final DC connection or closing DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative (-).

2. Operation

2.1 Basic Operation

The inverter features an LCD display, function buttons, and an RGB indicator for status monitoring and control.

  • LCD Display: Shows real-time system status, input/output parameters, and error codes.
  • Function Buttons: Navigate menus and adjust settings on the LCD.
  • RGB Indicator: Provides visual cues for operational status (e.g., charging, fault).
  • Power On/Off Switch: Located on the side of the unit for manual power control.

2.2 Smart Load Management and Grid Interaction

The inverter offers dual output for efficient load management and can feed excess solar energy back into the utility grid.

Diagram illustrating how the inverter feeds into the grid, showing solar panels, a house, and a city grid with wind turbines and solar farms.
Figure 5: Grid Interaction and Energy Flow.

If solar energy is sufficient to power all connected loads and charge the battery, the solar energy can be fed back to the grid. If solar energy is not sufficient to power all connected loads, utility energy will supply power to the loads simultaneously.

The inverter supports multiple output priorities: UTL (Utility first), SOL (Solar first), SBU (Solar-Battery-Utility), and SUB (Solar-Utility-Battery).

2.3 Remote Monitoring

With built-in WiFi, you can monitor and control your inverter using a dedicated smartphone application.

Image showing three inverter models and a smartphone displaying a monitoring app, indicating WiFi remote control.
Figure 6: Monitor and Control via Smart App.

The app allows you to check the status of your device, view energy production and consumption, and adjust certain settings remotely.

3. Maintenance

Regular maintenance ensures the longevity and optimal performance of your solar inverter.

  • Cleaning: Periodically clean the exterior of the inverter to prevent dust buildup. The inverter features a detachable dust cover for harsh environments, which should be cleaned regularly.
  • Connections: Inspect all electrical connections (PV, battery, AC input/output) for tightness and signs of corrosion. Ensure proper ventilation around the unit.
  • Firmware Updates: Check for available firmware updates via the monitoring app or manufacturer's website to ensure your inverter has the latest features and bug fixes.

4. Troubleshooting

This section provides general guidance for common issues. For specific error codes or complex problems, please refer to the detailed troubleshooting guide in the full product manual or contact technical support.

  • No Power: Check all power connections, including PV, battery, and AC input. Ensure the power on/off switch is in the 'ON' position.
  • Inverter Not Producing Power: Verify PV array connection and voltage. Check for any fault indicators on the LCD. Ensure sufficient sunlight for solar production.
  • Battery Not Charging: Confirm battery connections and voltage. Check solar charger settings and PV input.
  • Overload Protection: If the inverter shuts down due to overload, reduce the connected load. The inverter has overload protection at 5s @ >140% load and 10s @ 110%-140% load.
  • Communication Issues (WiFi): Ensure the inverter is within range of your WiFi network. Restart the inverter and your router if necessary. Check app settings.

5. Technical Specifications

Below are the detailed specifications for the Aninerel Hybrid Solar Inverter models.

ANL-4200T-24L-W-PRO Specifications

Specifications table for the ANL-4200T-24L-W-PRO model.
Figure 7: ANL-4200T-24L-W-PRO Technical Specifications.

ANL-6200T-48L-W-PRO Specifications

Specifications table for the ANL-6200T-48L-W-PRO model.
Figure 8: ANL-6200T-48L-W-PRO Technical Specifications.

ANL-11000T-48L-W-PRO Specifications

Specifications table for the ANL-11000T-48L-W-PRO model.
Figure 9: ANL-11000T-48L-W-PRO Technical Specifications.

General Specifications

AttributeValue
Brand NameANENJI
Model NumberAninerel-Solar inverter
Output Frequency50/60 Hz
Is Smart DeviceYes
OriginMainland China
CertificationCE
Operation Temperature-10℃-55℃
Storage temperature-15℃-55℃
Output AC Voltage Regulation220/230VAC±5%
Transfer Time10ms (For personal Computer); 20ms (For Home Appliances)
Maximum Efficiency98%
Humidity5% to 95% Relative Humidity (Non-condensing)
Weight8.2kg (may vary by model)

6. Warranty and Support

Your Aninerel Hybrid Solar Inverter comes with certain service commitments to ensure your satisfaction.

  • Free Returns: Enjoy free returns within 15 days of delivery.
  • Fast Delivery & Refunds:
    • Receive a $2.00 coupon code if delivery is delayed.
    • Full refund if the package is lost.
    • Full refund if items are damaged upon arrival.
    • Full refund if no delivery within 30 days.

For any technical assistance, warranty claims, or support inquiries, please contact the seller directly through your purchase platform. Provide your product model and a detailed description of the issue for prompt assistance.

7. User Tips

Based on available information, no specific user tips beyond the operational guidelines are provided. Always ensure proper ventilation around the inverter and keep the detachable dust cover clean, especially in harsh environments, to maintain optimal performance and extend the product's lifecycle.

Related Documents - ANL-4200T-24L-W-PRO, ANL-6200T-48L-W-PRO, ANL-11000T-48L-W-PRO

Preview ANENJI EM-T Series 6.2KW Off-Grid Hybrid Inverter Technical Specifications
Detailed technical specifications and features of the ANENJI EM-T Series 6.2KW Off-Grid Hybrid Inverter, including input/output power, battery compatibility, MPPT capabilities, and physical dimensions.
Preview ANENJI GM Series 5.5/6.2KW Hybrid Inverter: ON/OFF-GRID Technical Specifications
Comprehensive technical data for the ANENJI GM Series 5.5KW and 6.2KW ON/OFF-GRID Hybrid Inverters (PV 60-500Vdc). Features, operational modes, and detailed electrical and physical specifications for models GM5500-48PL and GM6200-48PL.
Preview ANENJI Solar Inverters, Charge Controllers, and Batteries Product Catalog
Explore the ANENJI range of high-efficiency solar inverters, MPPT solar charge controllers, and LiFePO4 batteries. Discover detailed specifications, features, and applications for residential and automotive use.
Preview User Manual: Hybrid Solar Inverter/Charger
Comprehensive user manual for the Hybrid Solar Inverter/Charger, covering installation, operation, specifications, and troubleshooting.
Preview ANENJI ANJ-2000W-12V-WiFi Off Grid Hybrid Inverter Technical Specifications
Detailed technical specifications for the ANENJI ANJ-2000W-12V-WiFi Off Grid Hybrid Inverter, including features, input/output parameters, battery specifications, and environmental data.
Preview ANENJI 3KVA Hybrid Solar Inverter/Charger User Manual
Comprehensive user manual for the ANENJI 3KVA Hybrid Solar Inverter/Charger, covering installation, operation, specifications, troubleshooting, and lithium battery setup. Includes detailed guidance on system configuration and fault resolution.