CEM DT-3398B

Contents

CEM DT-3398B True RMS Clamp Meter User Manual

Model: DT-3398B

1. Introduction

The CEM DT-3398B is a professional True RMS Clamp Meter designed for accurate AC and AC/DC current and voltage readings, even with non-linear waveforms. This versatile meter is suitable for a wide range of industrial and commercial applications, as well as for use in educational and laboratory settings where high current measurement is required.

Key features include a large and bright backlit display, CAT IV 1000V safety rating, easy clamp control, data tracking and analysis via Bluetooth mobile app, temperature measurement, NCV detection, flashlight, and auto power off.

CEM DT-3398B True RMS Clamp Meter

Figure 1: CEM DT-3398B True RMS Clamp Meter

2. Safety Information

WARNING: To avoid electric shock or personal injury, read all safety information before using the product.

  • Always adhere to local and national safety codes.
  • Use the meter only as specified in this manual; otherwise, the protection provided by the meter may be impaired.
  • Do not use the meter if it appears damaged or if it is not operating properly.
  • Verify the meter's operation by measuring a known voltage or current.
  • Do not apply more than the rated voltage, as marked on the meter, between the terminals or between any terminal and earth ground.
  • Use caution when working with voltages above 30 V AC RMS, 42 V peak, or 60 V DC. Such voltages pose a shock hazard.
  • Keep fingers behind the finger guards on the test probes.
  • Replace the battery as soon as the low battery indicator appears.
  • Disconnect the test leads from the circuit before changing functions.
  • Do not operate the meter with the case open.
  • Ensure the clamp jaw is fully closed before taking measurements.
Clamp meter designed to meet CAT IV requirements

Figure 2: The DT-3398B is designed to meet CAT IV requirements as defined by IEC 61010 (3rd edition) standard.

3. Product Overview

The DT-3398B clamp meter offers a robust design with double injection casing, making it strong and sturdy for professional use. It features a large and bright backlit display for clear readings in various lighting conditions.

3.1 Key Features

  • True RMS Measurement: Provides accurate readings for AC current and voltage, even with distorted waveforms.
  • High Current Capacity: Measures up to 2000A AC/DC current.
  • High Voltage Capacity: Measures up to 1000V AC/DC voltage.
  • Clamp Jaw Opening: 2 inches (52mm) for easy clamping around conductors.
  • Digital Display: 6000 counts with analog bargraph/segments.
  • Safety Rating: Electronic overload protection, CAT IV 1000V.
  • Data Functions: Data Hold, Peak Hold, MAX/MIN, Inrush current measurement, DCA Zero function.
  • Convenience Features: Flashlight, Backlight, NCV (Non-Contact Voltage) Detection, Auto Power Off, Low battery indication.
  • Connectivity: Bluetooth data transmission for data tracking and analysis via mobile app.
  • Temperature Measurement: Capable of temperature measurements, ideal for HVAC professionals.
CEM DT-3398B Clamp Meter with display and controls

Figure 3: Easy-to-use dials and buttons for various measurements.

4. Setup

4.1 Battery Installation

The DT-3398B requires 3 x 1.5V AA batteries (or 9V battery, depending on model variant, please check your specific packaging). To install or replace batteries:

  1. Ensure the meter is turned OFF and all test leads are disconnected.
  2. Locate the battery compartment cover on the back of the meter.
  3. Unscrew the retaining screw(s) and remove the cover.
  4. Insert the batteries, observing correct polarity (+ and -).
  5. Replace the battery cover and secure the screw(s).

4.2 Connecting Test Leads

For voltage, resistance, capacitance, diode, and continuity measurements:

  1. Insert the red test lead into the VΩCAP Hz% Temp terminal.
  2. Insert the black test lead into the COM terminal.
  3. Ensure connections are secure before use.

4.3 Mobile App Connection (Bluetooth)

The DT-3398B supports Bluetooth connectivity for data tracking and analysis:

  1. Download the official CEM mobile application from your device's app store.
  2. Turn on the DT-3398B clamp meter.
  3. Enable Bluetooth on your mobile device.
  4. Open the CEM app and follow the on-screen instructions to scan for and connect to your DT-3398B device.
  5. Once connected, you can view real-time measurements, log data, and perform analysis through the app.
CEM DT-3398B Clamp Meter connected to a mobile app via Bluetooth

Figure 4: Data tracking and analysis via Bluetooth link mobile APP.

5. Operating Instructions

5.1 Power On/Off

Rotate the function dial from the OFF position to any desired measurement function to turn the meter ON. To turn OFF, rotate the dial back to the OFF position.

5.2 AC/DC Current Measurement (Clamp)

  1. Rotate the function dial to the AC A or DC A position.
  2. Press the trigger to open the clamp jaw.
  3. Encircle only one conductor with the clamp jaw. Ensure the jaw is fully closed.
  4. Read the current value on the display.
  5. For DC current, use the DCA Zero function to zero out any offset before measurement.
Clamp meter measuring current in an electrical panel

Figure 5: Easy clamp control for quick and easy measurement.

5.3 AC/DC Voltage Measurement

  1. Connect the test leads as described in Section 4.2.
  2. Rotate the function dial to the AC V or DC V position.
  3. Touch the test probes to the desired test points in the circuit.
  4. Read the voltage value on the display.

5.4 Resistance Measurement

  1. Connect the test leads as described in Section 4.2.
  2. Rotate the function dial to the Ω (Resistance) position.
  3. Ensure the circuit under test is de-energized.
  4. Touch the test probes across the component to be measured.
  5. Read the resistance value on the display.

5.5 Capacitance Measurement

  1. Connect the test leads as described in Section 4.2.
  2. Rotate the function dial to the CAP (Capacitance) position.
  3. Ensure the capacitor is fully discharged before measurement.
  4. Touch the test probes across the capacitor terminals.
  5. Read the capacitance value on the display.

5.6 Temperature Measurement

  1. Connect the temperature probe to the VΩCAP Hz% Temp and COM terminals.
  2. Rotate the function dial to the TEMP position.
  3. Place the tip of the temperature probe on the surface or in the medium to be measured.
  4. Read the temperature value on the display.
Clamp meter measuring temperature with a probe

Figure 6: The DT-3398B makes temperature measurements, perfect for HVAC professionals.

5.7 NCV (Non-Contact Voltage) Detection

  1. Rotate the function dial to the NCV position.
  2. Move the top of the clamp meter near a conductor or outlet.
  3. The meter will indicate the presence of AC voltage through an audible beep and/or visual indicator.

5.8 Flashlight Function

The DT-3398B includes a built-in flashlight for illuminating dark work areas. Press the flashlight button (if available, typically integrated with another button or a dedicated one) to toggle it on/off.

Clamp meter flashlight illuminating a dark electrical panel

Figure 7: Using the integrated flashlight for visibility in low-light conditions.

5.9 Data Hold, Peak Hold, MAX/MIN

  • HOLD: Press the HOLD button to freeze the current reading on the display. Press again to release.
  • PEAK HOLD: For capturing transient peaks. Refer to the detailed manual for specific activation and usage.
  • MAX/MIN: Press the MAX/MIN button to record the maximum and minimum readings over a period. Press again to cycle through MAX, MIN, and current readings.

6. Maintenance

6.1 Cleaning

Wipe the meter with a dry, soft cloth. Do not use abrasives or solvents. Periodically clean the terminals with a cotton swab and detergent.

6.2 Battery Replacement

Refer to Section 4.1 for battery replacement instructions. Replace batteries promptly when the low battery indicator appears to ensure accurate readings and proper operation.

6.3 Calibration

For optimal accuracy, it is recommended to have the meter calibrated annually by a qualified service center.

6.4 Storage

If the meter is not to be used for an extended period, remove the batteries to prevent leakage and damage. Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.

7. Troubleshooting

ProblemPossible CauseSolution
Meter does not power on.Dead or incorrectly installed batteries.Check battery polarity; replace batteries.
No reading or "OL" (Overload) displayed.Incorrect function selected, range exceeded, or open circuit.Select correct function/range; check circuit continuity.
Inaccurate readings.Low battery, dirty terminals, or external interference.Replace batteries; clean terminals; move away from strong magnetic fields.
Bluetooth connection fails.Bluetooth not enabled, app issues, or meter too far from device.Ensure Bluetooth is on; restart app/meter; reduce distance.
Flashlight not working.Low battery or faulty LED.Replace batteries. If issue persists, contact support.

8. Specifications

FunctionMax RangeBasic AccuracyMax. Resolution
AC Current2000 A±(2.5%+5d)1A
DC Current2000 A±(3.0%+4d)1A
AC Voltage1000V±(0.8%+2d)0.1mV
DC Voltage1000V±(1.0%+4d)0.1mV
Resistance60MΩ±(1.0%+4d)0.1Ω
Capacitance10mF±(3.0%+5d)0.01nF
Electronic Frequency100kHz±(1.2%+3d)0.01kHz
Temperature1000°C/1832°F±(3.0%+5d)1°C/°F
Total Harmonic Distortion99.9%0.1%±(3% + 10d)
Harmonic distortion measurement99.9%0.1%±(5% + 10d)
Active Power999.9KWA.error x V.reading + V.error x A.reading*
Power Factor-1.0 ~ 0, 0 ~ 1.0*±(3% + 1d)
Continuity checkBuzzer sounds at 50Ω
Diode testTest current <0.5mA Max 3V

* indicates feature availability, specific resolution/accuracy details may vary slightly by model variant (3398, 3398B, 3398W).

Detailed specifications table for CEM DT-3398 series clamp meters

Figure 8: Detailed Specifications for DT-3398 series.

General Specifications:

  • Dimensions (HxWxD): 308mm x 97mm x 47mm
  • Weight: 732g
  • Operating Temperature: 0-40°C
  • Certification: CE, CAT IV 1000V
  • Power Supply: 1.5V AA x 3 Batteries

9. User Tips

  • Zeroing DC Current: Always use the DCA Zero function before taking DC current measurements to ensure accuracy.
  • Single Conductor Rule: When measuring current with the clamp, ensure only one conductor is inside the jaw. Clamping around multiple conductors (e.g., live and neutral) will result in a zero reading due to opposing magnetic fields.
  • Backlight Usage: Utilize the backlight feature in dimly lit environments for clear display visibility.
  • Mobile App Benefits: Leverage the Bluetooth mobile app for long-term data logging, trend analysis, and remote monitoring, which can be particularly useful for intermittent faults or performance tracking.
  • Safety First: Always wear appropriate personal protective equipment (PPE) such as insulated gloves and safety glasses when working with electrical circuits.

10. Warranty and Support

CEM products are warranted against defects in materials and workmanship for a specified period from the date of purchase. Please refer to your product's warranty card or contact CEM customer service for specific warranty terms and conditions.

For technical support, service, or repair, please contact your local distributor or CEM customer service. Ensure you have your product model number (DT-3398B) and serial number available when contacting support.

Contact Information:

  • WhatsApp: +86 15232138097
  • Email: kaigui8881@163.com

Video 1: Product demonstration of the CEM DT-3398B Clamp Meter, showcasing its features and use cases.

© 2024 CEM. All rights reserved. Information is subject to change without notice.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.