TTNergy TTN-MAX11KB

Contents

TTNergy TTN-MAX11KB Hybrid Solar Inverter User Manual

Model: TTN-MAX11KB | Brand: TTNergy

1. Introduction

The TTNergy TTN-MAX11KB is a multi-function hybrid solar inverter/charger designed to provide uninterruptible power support. It efficiently converts DC power from a PV array into usable AC power and works with batteries to store excess energy. This inverter is particularly useful in regions with unstable or absent grid electricity.

The grid-interactive inverter controls and monitors the connection of electricity from power plants, managing the dispatch of power based on demand and ensuring optimal performance.

2. Safety Information

  • Read all instructions and cautionary markings on the unit and in this manual before installation and operation.
  • Installation must be performed by qualified personnel.
  • Do not disassemble the unit. There are no user-serviceable parts inside.
  • Ensure proper grounding to prevent electric shock.
  • Keep the inverter away from flammable materials and ensure adequate ventilation.
  • Verify that the battery voltage and PV array voltage are compatible with the inverter's specifications.

3. Product Overview

3.1 Key Features

  • Higher yields, safe, reliable, smart, and user-friendly design.
  • Comprehensive LCD display for user-configurable settings.
  • Built-in Wi-Fi for mobile monitoring (Android/iOS apps available).
  • Supports USB On-the-Go function.
  • Lithium battery BMS support (for Pylontech, Weco, Soltaro).
  • Replaceable fan design for ease of maintenance.
  • Batteryless operation (single unit mode only).
  • Configurable AC/PV output usage timer and prioritization.
  • Selectable high power charging current and input voltage range.
  • Compatible with utility mains or generator input.
  • Built-in anti-dust kit.
  • Optional DC output for DC fan, LED bulb, router, etc.
  • Parallel operation up to 6 units with built-in parallel kit.
  • High PV input design, 500V (Voc) max input.

3.2 Components and Connections

Front and Rear Panel Diagram of TTNergy Hybrid Solar Inverter

Figure 3.2.1: Front and Rear Panel Diagram of the TTNergy Hybrid Solar Inverter.

Detailed view of inverter ports with labels

Figure 3.2.2: Detailed view of the inverter's ports and connections.

  1. Remote LCD Port: For connecting an optional remote LCD module.
  2. Dry Contact (Genset Starter): For generator auto-start functionality.
  3. BMS Port: For Lithium battery BMS communication (CAN, RS-485 or RS-232).
  4. RS232 Port: For communication with a computer or monitoring device.
  5. Battery Input: Connects to the battery bank.
  6. AC Output (Load): Connects to household loads.
  7. AC Input: Connects to the utility grid or generator.
  8. PV Input: Connects to the solar panel array.
  9. Parallel Communication Port: For connecting multiple inverters in parallel.
  10. USB Port: For USB On-the-Go function and communication.
  11. 12V DC Output Connectors (Option): For connecting low-power DC devices like fans or routers.
  12. Power Switch for DC Output (Option): Controls the optional 12V DC output.

4. Specifications

4.1 General Specifications (TTN-MAX11KB)

FeatureSpecification
Model NumberTTN-MAX11KB
Rated Power11000W
Surge Power22000VA
Battery Voltage48VDC
Input Voltage (PV)500VDC (Max PV Input Voltage)
Input Voltage (AC)90-280VAC (Inverter Mode), 170-280VAC (UPS Mode)
Output Voltage (AC)220V/230V/240V ±5%
Output Frequency50 Hz/60 Hz Auto sensing
WaveformPure Sine Wave
Max PV Charge Current150A
Max AC Charge Current150A
Max Charge Current150A
Inverter Efficiency (Peak)98%
MPPT Range Operating Voltage90 ~ 450 VDC
Transfer Time (AC to DC)10ms (Computer Equipment), 20ms (Household Equipment)
Parallel FunctionOptional, up to 6 units
Monitor FunctionOptional, WiFi monitor
Communication InterfaceUSB/RS232/RS485/WiFi/Dry-contact
Dimensions (DxWxH)147.4 × 432.5 × 553.6 mm
Net Weight18.4 kg
Operating Temperature0°C to 40°C
Storage Temperature-15°C to 60°C
Humidity20%~95% Relative Humidity (Non-condensing)
Altitude<1000m
Noise≤50dB
CertificateCE
Warranty2 Years

4.2 Other Models Comparison

FeatureTTN-Max 11000TTN-Max 8000TTN-Max 7200TTN-Max 6500
Capacity11000VA/11000W8000VA/8000W7200VA/7200W6500VA/6500W
ParallelYes, up to 6 units
INPUT
Selectable Voltage Range230 VAC120 VAC
Frequency Range170-280 VAC (PC); 90-280 VAC (Home Appliances)90-140 VAC (PC); 80-140 VAC (Home Appliances)
OUTPUT
AC Voltage Regulation (Batt. Mode)230 VAC ± 5%120 VAC ± 5%
Surge Power22000VA15000VA15000VA13000VA
Efficiency (Peak)90%~93%
Transfer Time15ms (PC), 20ms (Home Appliances)
WaveformPure Sine Wave
No Load Power Consumption<70W
BATTERY
Battery Voltage48 VDC
Floating Charge Voltage54 VDC
Overcharge Protection66 VDC
SOLAR CHARGER & AC CHARGER
Solar Charger TypeMPPT
Max. PV Array Open Circuit Voltage500VDC250VDC
MPP Range @ Operating Voltage90~450VDC90~230VDC
Max. PV Array Power11000W (5500W×2)8000W (4000W x2)
Max. Solar Charge Current150 A80 A120A
Max. AC Charge Current150 A80 A120A
Max. Charge Current150 A120 A80 A120A
PHYSICAL
Dimension, DxWxH (mm)147.4 × 432.5 × 553.6
Net Weight (kgs)18.4
Communication InterfaceUSB/RS232/RS485/WiFi/Dry-contact
ENVIRONMENT
Humidity5% to 95% Relative Humidity (Non-condensing)
Operating Temperature-10°C to 50°C-10°C to 40°C
Storage Temperature-15°C to 60°C

5. Installation and Setup

5.1 Physical Installation

The inverter should be mounted in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Ensure there is sufficient clearance around the unit for proper airflow. The unit's dimensions are 147.4 × 432.5 × 553.6 mm and it weighs 18.4 kg, so ensure the mounting surface can support its weight.

Inverter dimensions and battery compatibility types

Figure 5.1.1: Inverter dimensions and compatible battery types (Flooded, Gel, AGM, Lithium, User Custom).

5.2 Electrical Connections

All electrical connections (PV, Battery, AC Input, AC Output) must be made according to local electrical codes and safety standards. Refer to the connection points described in Section 3.2. Ensure all connections are secure and properly insulated.

  • PV Connection: Connect your solar panel array to the PV input terminals. Ensure the PV array open circuit voltage and power are within the inverter's specified limits (Max 500VDC, Max 11000W for TTN-MAX11KB).
  • Battery Connection: Connect the battery bank to the Battery Input terminals. Observe correct polarity. The inverter supports 48VDC battery systems.
  • AC Input Connection: Connect the utility grid or a compatible generator to the AC Input terminals.
  • AC Output Connection: Connect your household loads to the AC Output terminals.
  • Communication Connections: Connect optional remote LCD, BMS, RS232, or USB devices as needed.

6. Operation

6.1 LCD Display and Indicators

Inverter LCD display, indicators, and buttons

Figure 6.1.1: Inverter LCD display, indicators, and function buttons.

The inverter features a comprehensive LCD display (1) and various indicators to show its status and operational parameters.

  • LED Display (1): Shows real-time data such as AC input Voltage, AC input frequency, PV Voltage, PV Current, Output Voltage, Output Frequency, Battery Voltage, Load Current, etc.
  • Status Indicator (2): Indicates the general operational status of the inverter.
  • Charging Indicator (3): Shows the battery charging status.
  • Fault Indicator (4): Illuminates to indicate a fault condition.
  • Function Buttons (5): Used to navigate menus and configure settings on the LCD.
  • Power On/Off Switch (6): Controls the main power to the inverter.

6.2 Indicator Messages

LED IndicatorColorSolid/FlashingMessages
Setting LED 1GreenSolid OnOutput powered by utility
Setting LED 2GreenSolid OnOutput powered by PV
Setting LED 3GreenSolid OnOutput powered by battery
Status indicators (AC/INV)GreenSolid OnOutput is available in line mode
FlashingOutput is powered by battery in battery mode
Status indicators (CHG)GreenSolid OnBattery is fully charged
FlashingBattery is charging.

7. Parallel Connection

The TTN-MAX11KB inverter supports parallel operation of up to 6 units to increase overall power capacity. Proper power and communication connections are crucial for stable parallel operation.

Parallel connection wiring diagrams for multiple inverters

Figure 7.1.1: Various parallel connection wiring diagrams for 2, 3, 4, 5, and 6 inverters, including power and communication connections.

Refer to the detailed diagrams above for specific power and communication wiring configurations when connecting multiple inverters in parallel. Ensure all communication cables are correctly connected between units.

8. Maintenance

  • Regularly inspect the inverter for any signs of damage or wear.
  • Keep the inverter's ventilation openings clear of dust and debris to ensure proper cooling. The replaceable fan design facilitates maintenance.
  • Check all electrical connections periodically to ensure they are tight and free from corrosion.
  • Clean the exterior of the inverter with a dry cloth. Do not use liquid cleaners.
  • For any internal maintenance, contact qualified service personnel.

9. Troubleshooting

If the inverter is not functioning as expected, consider the following general troubleshooting steps:

  • No Power: Check the main power switch, battery connections, and AC input.
  • Fault Indicator On: Refer to the LCD display for specific error codes or messages and consult the full manual for detailed fault descriptions and solutions.
  • No Output: Verify that the load is connected correctly and not exceeding the inverter's capacity. Check battery charge level and PV input.
  • Overload Warning: Reduce the connected load.
  • Communication Issues: Ensure all communication cables are securely connected and that monitoring software/apps are correctly configured.

For persistent issues, contact technical support.

10. User Tips

  • Battery Capacity Matching: Correctly matching the battery capacity to your system's load requirements and application scenarios is crucial. An improperly sized battery bank can lead to insufficient power or wasted generation. Always refer to the manual's recommendations or consult with a solar energy professional.
  • Monitoring: Utilize the built-in Wi-Fi and mobile monitoring apps to keep track of your inverter's performance and system status remotely. This helps in proactive maintenance and optimization.
  • Parallel Expansion: If your power needs grow, remember that this inverter supports parallel operation for up to 6 units, offering a scalable solution for increased capacity.

11. Warranty and Support

11.1 Warranty

The TTNergy TTN-MAX11KB Hybrid Solar Inverter comes with a 2-year warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use and service. Please retain your proof of purchase for warranty claims.

11.2 Technical Support

For technical assistance, troubleshooting, or warranty inquiries, please contact your vendor or the manufacturer directly. You may also reach out via WhatsApp: +86 19897109233 for faster response and support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.