1. Introduction
The TSUN MA06LS is a micron-level precision magnetic ruler designed for accurate and reliable measurement in various industrial applications. Its all-in-one design allows for compact installation, making it suitable for environments where space is a premium. This manual provides detailed instructions for the proper installation, operation, and maintenance of your MA06LS magnetic ruler to ensure optimal performance and longevity.
2. Key Features
- MA06LS Magnetic Grating Display.
- Intelligent LCD backlight display for clear readings.
- Iconic definition of common function shortcut keys (modify current value, modify direction, sensor adaptive mode).
- Non-contact measurement, ensuring no wear and tear on components.
- High protection level, resistant to oil and dust.
3. Specifications
General Product Information
- Battery Included: No
- High-concerned chemical: None
- Origin: Mainland China
Technical Specifications
| Category | Parameter | Value |
|---|---|---|
| Mechanical Performance | Max. External Dimensions | 73.7mm × 36.2mm × 29.56mm |
| Opening Size | 67.6mm × 32.1mm | |
| Readhead Cable | Default 1M (customizable) | |
| Readhead Gap | Standard 1-2mm | |
| Movement Speed | Max. 5m/s | |
| Matching Magnetic Strip | TR50/5mm+5mm | |
| Electrical Performance | System Accuracy | ±(0.03 + 0.01*L) L=meter |
| Repeatability | Max. ±0.01mm | |
| Resolution | 0.01, 0.05, 0.1, 1 | |
| Display Range | -99999 ~ 999999 | |
| Power Consumption | Max. 400uA | |
| Internal Battery | Two No. 5 batteries (long standby) | |
| Environmental | Operating Temperature | -20°C ~ 70°C |
4. Components
The TSUN MA06LS system typically includes the display unit (readhead) and a magnetic strip. The magnetic strip is composed of three parts:
- A: Soft magnetic strip
- B: Non-magnetic strip
- C: Protective layer (an A-type soft magnetic strip with a steel strip for protection).
The magnetic strip has a total thickness of 1.8mm, a width of 10mm, and is typically supplied in 50m roll packaging.
5. Installation
5.1 Magnetic Strip Preparation
For adhesive magnetic strips, ensure the surface where the strip will be applied is thoroughly cleaned. Use a mixture of 50% alcohol and 50% water, or acetone (consult manufacturer for suitable solvents). The surface must be clean and free of oil and dust before bonding.
5.2 Readhead Installation
- The optimal control distance between the readhead and the magnetic strip is 0.8mm to 1.0mm.
- When installing the readhead, ensure the readhead mark is precisely aligned with the sensing magnetic strip.
- Observe the following angle deviation requirements for the readhead installation:
- Lateral deviation: +/-3mm
- Angular deviation (pitch): +/-5 degrees
- Angular deviation (yaw): +/-1.5 degrees
- If a 0.8mm thick protective film or spacer is used during installation, remove it after the readhead is securely mounted.
6. Operation
6.1 Display Unit Overview
The MA06LS display unit features an intelligent LCD backlight display and four function buttons:
6.2 Button Functions
| Button | Function (Short Press) | Function (Long Press) |
|---|---|---|
| P (F1) | Function / Confirm | Enter parameters to be modified |
| ▲ (F2) | Modify parameter | Learning (adjusting readhead-magnetic strip gap, calibration) |
| ► (F3) | Switch parameter / Switch number | Modify operation direction (0 or 1) |
| C (F4) | Clear / Exit current mode | Modify current value (confirm with 'P' after modification) |
6.3 Parameter Settings (P01-P22)
Access these parameters by long-pressing the 'P' (F1) button. Use the '▲' (F2) and '►' (F3) buttons to navigate and modify values, and 'P' (F1) to confirm changes. Some parameters require a password (1234 or 4321 or 5321) to access.
| Parameter | Description | Range/Default | Notes |
|---|---|---|---|
| P01 | Current Value | -99999~999999 (Default: 0) | Saves input value to current value. Confirm with 'P' after modification. |
| P02 | Measurement Direction | 0~1 (Default: 0) | 0 or 1 represents two directions. Change sensor direction or measurement direction. |
| P03 | Self-adaptive Calibration | GO (Default: GO) | Enter calibration state. Move sensor quickly (or repeatedly) over 150mm magnetic strip for ~10s. If calibration is incorrect, adjust sensor-magnetic strip distance (1-2mm). |
| P10 | Measurement Unit Switch | 00 (Default: 00) | 00: Absolute; 01: MM; 10: INCH Absolute; 11: INCH Relative; 20: Angle; 21: Angle Relative. (Password: 1234) |
| P11 | Ratio Coefficient | 0.00001~2.99999 (Default: 1) | Display value = measured value * ratio coefficient. (Password: 1234) |
| P12 | Concentric Diameter | 0.01~999.99 (Default: 500.00) | Magnetic strip origin diameter. Diameter plus magnetic strip thickness (1.5mm*2=3mm). |
| P13 | Resolution | 0.1, 0.05, 0.1, 1 | Length unit: mm, corresponding angle: ". (Password: 1234) |
| P15 | Timed Screen Off | 0~1 (Default: 0) | 0: Not enabled; 1: Screen off after 5 minutes. Any key press wakes. (Password: 1234) |
| P20 | Restore Factory Settings | SURE? (Default: No) | Restores factory settings. (Password: 4321) |
| P21 | Sensor Debugging Function | SURE? (Default: No) | Enables sensor debugging function. (Password: 5321, enter parameters) |
| P22 | Sensor Debugging Backup | SURE? (Default: No) | Performs sensor debugging backup. (Password: 5321, enter parameters) |
7. Maintenance
7.1 Battery Replacement
When the battery low indicator is displayed on the screen, replace the two No. 5 (AA) batteries immediately. Replace them one by one to avoid data loss during the process.
7.2 Cleaning
The magnetic strip should be kept clean. If cleaning is required, use a mixture of 50% alcohol and 50% water, or acetone. Ensure the surface is free of oil and dust.
7.3 General Care
- The MA06LS is designed for non-contact measurement and is resistant to oil and dust, but regular inspection for debris accumulation is recommended.
- Avoid exposing the unit to extreme temperatures outside the specified operating range (-20°C to 70°C).
8. Troubleshooting
8.1 Error Codes
The display unit may show error codes to indicate specific issues:
| Error Code | Description |
|---|---|
| E01 | Parameter input error |
| E04 | Sensor fault, sensor short circuit |
| E05 | Sensor fault, sensor open circuit |
| E06 | Magnetic strip loss (possible causes: 1: Sensor damage; 2: Magnetic strip damage; 3: Readhead too far from magnetic strip) |
| E07 | Battery low, replace battery immediately |
| E08 | Readhead too close to magnetic strip |
| E09 | Readhead too far from magnetic strip |
| E10 | Sensor value exceeds display range |
8.2 General Precautions
- The standard distance from the readhead to the magnetic strip is 1mm. Deviations can affect accuracy.
- If the readhead is too far from the magnetic strip, it will significantly affect accuracy and may even render the unit unusable.
- The sensor cable should not be bent at a radius less than 25mm to prevent damage.
- Ensure the device being measured is separated from sources of electromagnetic interference (e.g., circuit breakers, relays, motors, contactors, clutches, dimmers) by more than 0.5 meters.
- Separate the signal line and power line to reduce electrical noise interference.
9. User Tips
- For initial setup, perform the self-adaptive calibration (P03) to ensure the sensor is correctly aligned with the magnetic strip.
- Regularly check the readhead-to-magnetic strip gap to maintain optimal measurement accuracy.
- When replacing batteries, ensure you have two fresh AA batteries and replace them one at a time to prevent any potential data loss or reset issues.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your vendor or the manufacturer directly. Keep your purchase receipt as proof of purchase.
11. Product Video
The following video provides a general introduction to various industrial components, offering a broader context of the manufacturer's product range. While not specific to the MA06LS magnetic ruler, it showcases related industrial applications.