TSUN MA06LS

Contents

TSUN MA06LS Magnetic Ruler User Manual

Model: MA06LS | Brand: TSUN

1. Introduction

The TSUN MA06LS is a micron-level precision magnetic ruler designed for accurate and reliable measurement in various industrial applications. Its all-in-one design allows for compact installation, making it suitable for environments where space is a premium. This manual provides detailed instructions for the proper installation, operation, and maintenance of your MA06LS magnetic ruler to ensure optimal performance and longevity.

2. Key Features

  • MA06LS Magnetic Grating Display.
  • Intelligent LCD backlight display for clear readings.
  • Iconic definition of common function shortcut keys (modify current value, modify direction, sensor adaptive mode).
  • Non-contact measurement, ensuring no wear and tear on components.
  • High protection level, resistant to oil and dust.
Key features of the TSUN MA06LS Magnetic Ruler.
This image lists the main features of the MA06LS, including its display type, shortcut key functionality, measurement method, and environmental resistance.

3. Specifications

General Product Information

  • Battery Included: No
  • High-concerned chemical: None
  • Origin: Mainland China

Technical Specifications

Category Parameter Value
Mechanical Performance Max. External Dimensions 73.7mm × 36.2mm × 29.56mm
Opening Size 67.6mm × 32.1mm
Readhead Cable Default 1M (customizable)
Readhead Gap Standard 1-2mm
Movement Speed Max. 5m/s
Matching Magnetic Strip TR50/5mm+5mm
Electrical Performance System Accuracy ±(0.03 + 0.01*L) L=meter
Repeatability Max. ±0.01mm
Resolution 0.01, 0.05, 0.1, 1
Display Range -99999 ~ 999999
Power Consumption Max. 400uA
Internal Battery Two No. 5 batteries (long standby)
Environmental Operating Temperature -20°C ~ 70°C
Technical specifications and advanced key parameter settings for TSUN MA06LS Magnetic Ruler.
This image details the electrical and mechanical specifications of the MA06LS, along with a table explaining advanced parameter settings (P01-P22) and their functions, default values, and notes.

4. Components

The TSUN MA06LS system typically includes the display unit (readhead) and a magnetic strip. The magnetic strip is composed of three parts:

  • A: Soft magnetic strip
  • B: Non-magnetic strip
  • C: Protective layer (an A-type soft magnetic strip with a steel strip for protection).

The magnetic strip has a total thickness of 1.8mm, a width of 10mm, and is typically supplied in 50m roll packaging.

Diagram showing magnetic strip components, readhead installation guidelines, and important precautions for TSUN MA06LS.
This image illustrates the three-part composition of the magnetic strip, provides detailed instructions and diagrams for correct readhead installation, including critical distance and angle tolerances, and lists essential precautions for optimal performance and safety.

5. Installation

5.1 Magnetic Strip Preparation

For adhesive magnetic strips, ensure the surface where the strip will be applied is thoroughly cleaned. Use a mixture of 50% alcohol and 50% water, or acetone (consult manufacturer for suitable solvents). The surface must be clean and free of oil and dust before bonding.

5.2 Readhead Installation

  1. The optimal control distance between the readhead and the magnetic strip is 0.8mm to 1.0mm.
  2. When installing the readhead, ensure the readhead mark is precisely aligned with the sensing magnetic strip.
  3. Observe the following angle deviation requirements for the readhead installation:
    • Lateral deviation: +/-3mm
    • Angular deviation (pitch): +/-5 degrees
    • Angular deviation (yaw): +/-1.5 degrees
  4. If a 0.8mm thick protective film or spacer is used during installation, remove it after the readhead is securely mounted.
Diagram showing magnetic strip components, readhead installation guidelines, and important precautions for TSUN MA06LS.
Detailed diagram illustrating readhead dimensions, magnetic strip dimensions, and acceptable installation angle deviations.

6. Operation

6.1 Display Unit Overview

The MA06LS display unit features an intelligent LCD backlight display and four function buttons:

Front view of TSUN MA06LS Magnetic Ruler display unit.
The display unit of the TSUN MA06LS Magnetic Ruler, showing the digital readout and four function buttons (P, F2, F3, C).

6.2 Button Functions

Button Function (Short Press) Function (Long Press)
P (F1) Function / Confirm Enter parameters to be modified
▲ (F2) Modify parameter Learning (adjusting readhead-magnetic strip gap, calibration)
► (F3) Switch parameter / Switch number Modify operation direction (0 or 1)
C (F4) Clear / Exit current mode Modify current value (confirm with 'P' after modification)

6.3 Parameter Settings (P01-P22)

Access these parameters by long-pressing the 'P' (F1) button. Use the '▲' (F2) and '►' (F3) buttons to navigate and modify values, and 'P' (F1) to confirm changes. Some parameters require a password (1234 or 4321 or 5321) to access.

Parameter Description Range/Default Notes
P01 Current Value -99999~999999 (Default: 0) Saves input value to current value. Confirm with 'P' after modification.
P02 Measurement Direction 0~1 (Default: 0) 0 or 1 represents two directions. Change sensor direction or measurement direction.
P03 Self-adaptive Calibration GO (Default: GO) Enter calibration state. Move sensor quickly (or repeatedly) over 150mm magnetic strip for ~10s. If calibration is incorrect, adjust sensor-magnetic strip distance (1-2mm).
P10 Measurement Unit Switch 00 (Default: 00) 00: Absolute; 01: MM; 10: INCH Absolute; 11: INCH Relative; 20: Angle; 21: Angle Relative. (Password: 1234)
P11 Ratio Coefficient 0.00001~2.99999 (Default: 1) Display value = measured value * ratio coefficient. (Password: 1234)
P12 Concentric Diameter 0.01~999.99 (Default: 500.00) Magnetic strip origin diameter. Diameter plus magnetic strip thickness (1.5mm*2=3mm).
P13 Resolution 0.1, 0.05, 0.1, 1 Length unit: mm, corresponding angle: ". (Password: 1234)
P15 Timed Screen Off 0~1 (Default: 0) 0: Not enabled; 1: Screen off after 5 minutes. Any key press wakes. (Password: 1234)
P20 Restore Factory Settings SURE? (Default: No) Restores factory settings. (Password: 4321)
P21 Sensor Debugging Function SURE? (Default: No) Enables sensor debugging function. (Password: 5321, enter parameters)
P22 Sensor Debugging Backup SURE? (Default: No) Performs sensor debugging backup. (Password: 5321, enter parameters)
Technical specifications and advanced key parameter settings for TSUN MA06LS Magnetic Ruler.
Detailed parameter settings for the MA06LS display unit.

7. Maintenance

7.1 Battery Replacement

When the battery low indicator is displayed on the screen, replace the two No. 5 (AA) batteries immediately. Replace them one by one to avoid data loss during the process.

7.2 Cleaning

The magnetic strip should be kept clean. If cleaning is required, use a mixture of 50% alcohol and 50% water, or acetone. Ensure the surface is free of oil and dust.

7.3 General Care

  • The MA06LS is designed for non-contact measurement and is resistant to oil and dust, but regular inspection for debris accumulation is recommended.
  • Avoid exposing the unit to extreme temperatures outside the specified operating range (-20°C to 70°C).

8. Troubleshooting

8.1 Error Codes

The display unit may show error codes to indicate specific issues:

Error Code Description
E01 Parameter input error
E04 Sensor fault, sensor short circuit
E05 Sensor fault, sensor open circuit
E06 Magnetic strip loss (possible causes: 1: Sensor damage; 2: Magnetic strip damage; 3: Readhead too far from magnetic strip)
E07 Battery low, replace battery immediately
E08 Readhead too close to magnetic strip
E09 Readhead too far from magnetic strip
E10 Sensor value exceeds display range
Detailed diagram of TSUN MA06LS key functions, display information, and error codes.
Table of error messages and their corresponding information prompts.

8.2 General Precautions

  • The standard distance from the readhead to the magnetic strip is 1mm. Deviations can affect accuracy.
  • If the readhead is too far from the magnetic strip, it will significantly affect accuracy and may even render the unit unusable.
  • The sensor cable should not be bent at a radius less than 25mm to prevent damage.
  • Ensure the device being measured is separated from sources of electromagnetic interference (e.g., circuit breakers, relays, motors, contactors, clutches, dimmers) by more than 0.5 meters.
  • Separate the signal line and power line to reduce electrical noise interference.

9. User Tips

  • For initial setup, perform the self-adaptive calibration (P03) to ensure the sensor is correctly aligned with the magnetic strip.
  • Regularly check the readhead-to-magnetic strip gap to maintain optimal measurement accuracy.
  • When replacing batteries, ensure you have two fresh AA batteries and replace them one at a time to prevent any potential data loss or reset issues.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your vendor or the manufacturer directly. Keep your purchase receipt as proof of purchase.

11. Product Video

The following video provides a general introduction to various industrial components, offering a broader context of the manufacturer's product range. While not specific to the MA06LS magnetic ruler, it showcases related industrial applications.

© 2024 TSUN. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.