1. Introduction
The NJTY T1 is a compact, fully intelligent digital multimeter designed for precise and safe electrical measurements. Featuring True RMS measurement, automatic range selection, and non-contact voltage (NCV) detection, it simplifies electrical testing for both professionals and DIY enthusiasts. Its small size and intelligent identification make it easy to use and carry.

2. Safety Information
Please read and understand all safety information and operating instructions in this manual before using the multimeter. Failure to follow these instructions could result in electric shock, fire, or serious injury.
- Always remove test leads before opening the battery cover or case to avoid electrical shock.
- Ensure the multimeter is in good working condition before use. Do not use if damaged.
- Do not apply voltage or current that exceeds the maximum specified limits for the multimeter.
- Use caution when working with voltages above 30V AC RMS, 42V peak, or 60V DC. These voltages pose a shock hazard.
- Always use the correct terminals, function, and range for your measurements.
- Replace batteries promptly when the low battery indicator appears to ensure accurate readings.

3. Product Overview and Components
Familiarize yourself with the different parts of your NJTY T1 Digital Multimeter:

- Display Screen: Shows measurement readings and indicators.
- Power On/Off Button: Turns the device on or off.
- Flashlight/Backlight Button: Activates the built-in flashlight and display backlight.
- HOLD/NCV Button:
- Short press: Activates Data Hold to freeze the current reading.
- Long press: Activates Non-Contact Voltage (NCV) detection mode.
- NCV Sensing Area: Located at the top, used for non-contact voltage detection.
- Positive Terminal Socket: For connecting the red test lead.
- Negative Terminal Socket: For connecting the black test lead.
- Pull String: For convenient carrying.
4. Setup
4.1. Battery Installation
The NJTY T1 Multimeter requires two AAA batteries (not included) for operation.
- Ensure the multimeter is turned off and disconnect any test leads from the input terminals.
- Locate the battery compartment on the back of the device.
- Use a screwdriver to open the battery compartment cover.
- Insert two 1.5V AAA batteries, observing the correct polarity (+ and -) as indicated inside the compartment.
- Replace the battery compartment cover and secure it with the screw.

Note: The multimeter will display a low battery indicator when the batteries need replacement.
5. Operating Instructions
The NJTY T1 features a fully intelligent auto-ranging function, meaning it automatically identifies the measurement type (AC/DC voltage, resistance, continuity) and selects the appropriate range upon power-on. No manual gear shifting is required.
5.1. Power On/Off
- Press the red power button to turn the multimeter on. The display will show "Auto".
- Press and hold the red power button to turn the multimeter off.
- The device also features an auto-off function to conserve battery power after a period of inactivity.
5.2. Connecting Test Leads
For most measurements, connect the black test lead to the negative terminal socket and the red test lead to the positive terminal socket.
5.3. Measuring AC/DC Voltage
The multimeter automatically detects AC or DC voltage. Simply connect the test leads to the circuit or component you wish to measure.


5.4. Measuring Resistance
To measure resistance, ensure the circuit is de-energized. The multimeter will automatically detect resistance when the test leads are connected across the component.

5.5. Continuity Test
The multimeter can perform a continuity test, indicated by a buzzer and light. If the resistance is below approximately 50Ω, the buzzer will sound, and the indicator light will illuminate.

5.6. Non-Contact Voltage (NCV) Detection
To detect AC voltage without contact:
- Long press the "HOLD NCV" button to enter NCV mode.
- Move the NCV sensing area (top of the multimeter) close to the conductor.
- The multimeter will indicate the presence of AC voltage through visual and/or audible alerts.

5.7. Data Hold
During a measurement, short press the "HOLD NCV" button to freeze the current reading on the display. Press it again to release the hold function.
5.8. Flashlight and Backlight
Press the flashlight/backlight button to turn on the built-in flashlight for emergency lighting or to illuminate the measurement area. Press it again to activate the display backlight for better visibility in low-light conditions. Press a third time to turn both off.

5.9. True RMS Measurement
The NJTY T1 features True RMS measurement, which is crucial for accurately measuring AC current and voltage, especially when dealing with non-sine waveforms or distorted mains power. Unlike common multimeters that calculate average values, True RMS measures the real effective value, providing more precise results for complex electrical signals.

6. Maintenance
- Cleaning: Wipe the multimeter with a damp cloth and mild detergent. Do not use abrasives or solvents.
- Storage: If the multimeter is not used for a long period, remove the batteries to prevent leakage. Store in a cool, dry place.
- Battery Replacement: Replace batteries when the low battery indicator appears. Refer to Section 4.1 for instructions.
- Calibration: The multimeter is factory calibrated. For professional use, periodic calibration may be required.
7. Troubleshooting
- No Display/Power: Check battery installation and ensure batteries are not depleted. Replace if necessary.
- Inaccurate Readings: Ensure test leads are properly connected. Check battery level. Verify the correct measurement function is being used (though T1 is auto-ranging, extreme conditions might require checking).
- No NCV Detection: Ensure NCV mode is activated (long press HOLD NCV button). Make sure the NCV sensing area is close enough to the AC voltage source.
- Buzzer Not Sounding for Continuity: Check if the resistance is above 50Ω. Ensure test leads are making good contact.
8. Specifications
The following table outlines the key specifications of the NJTY T1 Digital Multimeter:
| Function Model | T1 |
|---|---|
| AC Voltage | 0.01V ~ 600V ± (0.8%+5) |
| DC Voltage | 0.01V ~ 600V ± (1.0%+5) |
| Resistance | 1Ω ~ 40MΩ ± (1.0%+10) |
| NCV | ✓ |
| Continuity Buzzer | ✓ |
| True RMS | ✓ |
| Back Light | ✓ |
| Underbattery display | ✓ |
| Auto power-off | ✓ |
| Data Hold | ✓ |
| Display | 4000 counts |
| Product size | 123L*61W*24Hmm |
| Product weight | About 78g (No batteries) |
| Power supply | 2*AAA batteries (Batteries not included) |


9. User Tips
- Portability: The compact size of the T1 makes it very easy to carry for on-the-go measurements.
- Auto-Ranging Convenience: Take advantage of the fully automatic mode; you typically don't need to manually select ranges, simplifying quick checks.
- Check Batteries: Ensure fresh batteries are installed for optimal performance and accurate readings, especially if you haven't used it in a while.
10. Warranty and Support
For detailed warranty information, technical support, or further assistance, please refer to the official user manual PDF provided by the manufacturer. A digital copy of the user manual can be accessed via this link: NJTY T1 User Manual (PDF).
The product package typically includes the multimeter, test leads, and a user manual. Please check all contents upon receipt.