EARU KWS-AC301

Contents

EARU KWS-AC301 Digital AC Voltmeter Ammeter Wattmeter KWh Energy Meter Instruction Manual

Model: KWS-AC301

1. Important Safety Instructions

WARNING

This product does not feature an explosion-proof structure and must not be used in flammable environments, such as those containing flammable gases, liquids, or explosives.

SAFETY INFORMATION

  1. Please use this product in accordance with the instructions in this manual.
  2. Do not disassemble this product by yourself.
  3. Pay attention to the rated voltage for use.

2. Product Description

The EARU KWS-AC301 is an instrument and equipment used to measure, record, display, and analyze parameters related to electric energy. It is widely applied in various stages of the power system, including power generation, transmission, distribution, and consumption.

This meter provides comprehensive monitoring of electrical parameters, including voltage, current, power, energy consumption (KWh), timing, temperature, frequency, and power factor. It is designed for optimal performance and ease of use.

3. Product Models and Specifications

The KWS series offers different models with varying capabilities. Below are the detailed specifications for the KWS-AC300 and KWS-AC301 models.

3.1. Model Comparison

Comparison table of KWS-AC300 and KWS-AC301 features
Figure 1: Feature Comparison between KWS-AC300 and KWS-AC301
Feature KWS-AC300-20A KWS-AC300-100A KWS-AC301-20A KWS-AC301L-20A KWS-AC301-100A KWS-AC301L-100A
Voltage AC50-300V AC50-300V AC50-300V AC50-300V AC50-300V AC50-300V
Current 0-20A 0-100A 0-20A 0-20A 0-100A 0-100A
Power 0-3000W 0-30KW 0-4400W 0-4400W 0-22KW 0-22KW
Capacity (KWh) 0.01-19999Kwh 0.01-19999Kwh 0.01-99999Kwh 0.01-99999Kwh 0.01-99999Kwh 0.01-99999Kwh
Timing 0-200H 0-200H 0-999 0-999 0-999 0-999
Temperature -10°C to 99°C -10°C to 99°C -10°C to 150°C -10°C to 150°C -20°C to 150°C -20°C to 150°C
Frequency 45-65Hz 45-65Hz 50-60Hz 50-60Hz 50-60Hz 50-60Hz
Power Factor N/A N/A 0.01-1PF 0.01-1PF 0.01-1PF 0.01-1PF
Shunt Way External (for 100A) External (for 100A) Built-in Built-in External (Closed Sensor) External (Closed Sensor)
485 Communication No No No Yes No Yes

3.2. Dimensions

Dimensions of KWS-AC300 and KWS-AC301 meters and CT coil
Figure 2: Dimensions of KWS-AC300 and KWS-AC301 meters and CT coil. All CT coils have a diameter of 15mm.
  • KWS-AC300: 79mm (Length) x 37.5mm (Width) x 20.7mm (Depth)
  • KWS-AC301: 73mm (Length) x 44mm (Width) x 24mm (Depth)
  • CT Coil Diameter: 15mm for all models.

4. Components

The package typically includes the following components:

  • Main Meter Unit (KWS-AC300 or KWS-AC301)
  • Current Transformer (CT Coil) - for 100A models, or external for AC300-100A. 20A models may have built-in shunt or no external CT.
  • Temperature Sensor (for KWS-AC301/AC301L models)
  • Connection Cables
  • User Manual (this document)
Video 1: Unboxing and overview of KWS-AC300 and KWS-AC301 components.
Components of KWS-AC301-100A including meter, CT coil, and cables
Figure 3: Typical components for KWS-AC301-100A model.

5. Setup Instructions

Proper wiring is essential for accurate and safe operation. Refer to the diagrams below for connection details.

5.1. KWS-AC301-100A Wiring Diagram (Closed Sensor)

Wiring diagram for KWS-AC301-100A with closed current transformer
Figure 4: Wiring Diagram for KWS-AC301-100A (Closed Sensor).

Connection Steps:

  1. Connect the main AC power supply (L and N) to the input terminals (IN-AC) of the meter.
  2. Connect the load to the output terminals (LOAD) of the meter.
  3. Pass the live wire (L) of the circuit through the Current Transformer (CT coil). Ensure the direction is correct as indicated by the arrow on the CT coil (if present).
  4. Connect the CT coil wires to the designated CT input terminals on the meter.
  5. For KWS-AC301L models, connect the 485 communication interface and temperature sensor if applicable.
KWS-AC301L with 485 Communication Interface and Temperature Sensor Interface
Figure 5: KWS-AC301L showing Temperature Sensor Interface and 485 Interface (RS485 A+, B-).

Note:

  • For 20A models without an external CT coil, the current measurement is internal.
  • Ensure all connections are secure before applying power.

6. Operating Instructions

The meters feature a clear display and intuitive buttons for operation.

6.1. KWS-AC301 Display and Button Functions

KWS-AC301 display layout with numbered indicators for Voltage, Current, Timing, Electric Energy, Electric Power, Power Factor, Frequency, Temperature, Up Key, Function Key, Down Key
Figure 6: KWS-AC301 Display and Button Layout.

Display Indicators:

  1. Voltage
  2. Current
  3. Timing
  4. Electric Energy (KWh)
  5. Electric Power (W)
  6. Power Factor (PF)
  7. Frequency (Hz)
  8. Temperature

Button Functions:

  • Up Key (▲): Used to navigate up or increase values in settings.
  • Down Key (▼): Used to navigate down or decrease values in settings.
  • Function Key (M): Used to enter settings, shift between parameters, and save settings.

6.2. KWS-AC301 Operating Instructions

  1. Viewing Parameters: Use the Up (▲) and Down (▼) keys to cycle through different display parameters.
  2. Entering Settings: Long press the M key for three seconds to enter the setting mode.
  3. Navigating Settings: Double-click the M key to wrap through settings, and click the M key to shift between parameters. The Up (▲) key moves the decimal point.
  4. Saving Settings: Long press the M key for 3 seconds to save the warning setting. A warning will only appear when the actual test value is greater than or equal to the set value. The meter will only sound when there is a warning. At the same time, the numerical unit will flash on the screen. For example, if the warning current is set to 1.0A, the warning will appear when the actual current is greater than 1.0A.
  5. Turning Off Warning: Set the warning value to be greater than the actual value or set all warning values to 0.
  6. Resetting Electric Energy and Timing: Long press the Up (▲) key for 3 seconds. When the timer flashes, click the M key to reset the timer. Double-click the M key to switch to electric energy, and click the M key to reset.
  7. Factory Data Reset: Long press the Down (▼) key, and then turn on the power. After the meter emits a sound, it means that the factory settings are reset successfully. The factory default voltage warning value is 275V, and all others are 0.
KWS-AC301 alarm setting illustration showing different parameters that can trigger an alarm
Figure 7: KWS-AC301 Alarm Setting Interface. Click M for 3 seconds to enter setting or alarm values.

6.3. KWS-AC300 Operating Instructions

KWS-AC300 display layout with numbered indicators for Temperature, Voltage, Power, Current, Keystroke, Timing, Power Factor, Electrical Energy
Figure 8: KWS-AC300 Display and Button Layout.

Operating Instructions:

Click the MENU button on the panel to view the power factor and cumulative electrical energy. To reset electrical energy and timing: Press and hold the MENU button for 5 seconds, the number in the timing area will flash, then click the button to select timing or energy reset. When the number flashes, double-click the button to reset. Press and hold the button for 5 seconds again to save the settings.

7. Maintenance

To ensure the longevity and accuracy of your EARU KWS-AC301/AC300 meter, follow these maintenance guidelines:

  • Keep the device clean and free from dust and moisture. Use a soft, dry cloth for cleaning.
  • Avoid exposing the meter to extreme temperatures or direct sunlight for prolonged periods.
  • Ensure all connections remain tight and free from corrosion. Periodically check wiring for any signs of wear or damage.
  • Do not attempt to open or repair the device yourself, as this may void the warranty and pose a safety risk.
  • Store the meter in a cool, dry place when not in use.

8. Troubleshooting

If you encounter issues with your meter, refer to the following common problems and solutions:

Problem Possible Cause Solution
Meter does not power on / No display No power supply; Loose wiring; Faulty unit. Check power connections. Ensure input voltage is within AC50-300V range. Verify wiring is secure. If problem persists, contact support.
Incorrect readings (Voltage, Current, Power) Incorrect wiring; CT coil installed incorrectly or faulty; Meter calibration issue. Review wiring diagrams (Figure 4) carefully. Ensure CT coil is installed on the correct wire and in the correct direction. Perform a factory reset (see Operating Instructions).
Internal buzzer not working (KWS-AC301) Alarm settings are off or set too high; Buzzer malfunction. Check alarm settings (see Operating Instructions) and ensure they are configured to trigger. Perform a factory reset. If the issue persists, the buzzer may be faulty.
Temperature sensor faulty (KWS-AC301/AC301L) Loose connection; Damaged sensor. Ensure the temperature sensor is securely connected to its interface (Figure 5). Inspect the sensor cable for damage. If damaged, the sensor may need replacement.
Electric energy or timing not resetting Incorrect reset procedure. Follow the specific reset instructions for your model carefully (see Operating Instructions).

9. User Tips

  • Initial Inspection: Upon receiving your meter, carefully inspect the packaging and contents for any signs of damage. It's recommended to test the unit as soon as possible to ensure full functionality.
  • Careful Handling: While installing, handle the meter and its components with care to avoid accidental damage to the display or internal circuitry.
  • Wiring Verification: Double-check all wiring connections against the provided diagrams before applying power to prevent short circuits or incorrect readings.
  • Refer to PDF: For a more detailed and printable version of the manual, please refer to the official PDF document available at EARU KWS-AC301 User Manual (PDF).

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. Keep your purchase receipt as proof of purchase.