PowMr POW-RELAB 3KU/KE, 5KU/KE, 10KU/KE

Contents

PowMr POW-RELAB Series Low Frequency Solar Inverter User Manual

Models: POW-RELAB 3KU/KE, 5KU/KE, 10KU/KE

1. Introduction and Safety Information

The PowMr POW-RELAB series is a line of all-in-one low frequency solar inverter-charger integrated machines designed for both residential and commercial applications. These units provide a pure sine wave output and intelligently manage inverter output and bypass functions to ensure a stable power supply to connected loads. They support both solar (PV) and AC grid charging, with configurable output and charging power priorities.

Important Safety Warnings:

  • DO NOT DISCONNECT BATTERIES WHILE THE UNIT IS IN OPERATION.
  • THIS UNIT SHOULD ONLY BE OPERATED BY AUTHORIZED PERSONNEL.
  • THE USER MANUAL SHOULD BE READ THOROUGHLY BEFORE OPERATION.
Rear view of PowMr solar inverter showing caution label and communication ports

Image: Rear view of the inverter highlighting the caution label and communication ports (RS232, BMS, RS485).

2. Package Contents

Upon unpacking, please verify that all items listed below are included in your package. If any items are missing or damaged, contact your supplier immediately.

Video: Unboxing the PowMr POW-RELAB series inverter, showing all included accessories.

  • PowMr POW-RELAB Solar Inverter Unit
  • User Manual
  • Communication Cable (for RS232/RS485)
  • Battery Fuse
  • Pair of Battery Terminals
  • 2 Cable Holders
  • Set of Screw Accessories (for mounting)
Image showing the package contents including the inverter, manual, cables, fuse, and mounting hardware.

Image: Visual representation of the inverter and its included accessories.

3. Key Features

  • All-in-One Design: Combines pure sine wave inverter output with mains or generator bypass functions.
  • Intelligent Management: Manages inverter output and bypass functions for stable power supply.
  • High Peak Power: Supports triple peak power, ensuring safe and stable operation under high-power loads. For example, the 3KW model can handle 9000W peak power.
  • Wide MPPT Voltage Range: Features a 60-150V MPPT range for efficient solar charging.
  • Battery Compatibility: Compatible with various battery types, including lithium and lead-acid batteries (AGM, FLD, GEL).
  • Flexible Charging: Supports both photovoltaic (solar) and AC grid charging with a maximum charging current of up to 120A.
  • Circuit Protection: Equipped with battery circuit fuses for enhanced safety.
  • Communication Ports: External communication supported via RS232 or RS485, including BMS communication for optimized battery operation and extended lifespan.
  • Multiple Protection Functions: Built-in multiple protection functions and precise alarm mechanisms for comprehensive system safety.
PowMr inverter with 'Effortless Surge Handling' text, showing continuous power of 3000W and peak power of 9000W, applied in an RV setting.

Image: Demonstrates the inverter's surge handling capability, suitable for powering appliances in an RV.

PowMr inverter highlighting 'Super-Ring-Transformator' with internal views of a toroidal transformer.

Image: Illustrates the internal toroidal transformer, contributing to load-bearing capacity and stability.

4. Specifications

FeaturePOW-RELAB 3KU/KEPOW-RELAB 5KU/KEPOW-RELAB 10KU/KE
Rated Power3000W5000W10000W
Output Voltage WaveformPure Sine Wave
Output Voltage RangePOW-RELAB KU: 110Vac±10%
POW-RELAB KE: 220Vac±10%
Output Frequency50Hz / 60Hz
Output Current80A
Efficiency>98%
Bypass ModeIntegrated
Nominal DC Input Voltage24Vdc48Vdc48Vdc
Max. PV Array Power1600W6400W6400W
MPPT Input Voltage Range30~150Vdc60~150Vdc60~150Vdc
Max. PV Array Open Circuit Voltage150Vdc
Maximum AC Charging Current38A29A60A
Max. PV Charging Current60A120A120A
Operating Temperature-10°C to 50°C
Storage Temperature-15°C to 50°C
HumidityRelative humidity from 5% to 95% (non-condensing)
Noise<45dB
Dimensions (LxWxH)465*310*135mm545*400*200mm
Net Weight19kg27.4kg51kg

5. Setup Instructions

Installation of the PowMr POW-RELAB series inverter should only be performed by qualified and authorized personnel due to the high voltages involved. Always ensure the unit is powered off and disconnected from all power sources (AC, PV, and Battery) before beginning any installation or maintenance work.

5.1 Mounting the Inverter

  • Choose a suitable location that is well-ventilated, dry, and away from direct sunlight or heat sources. Ensure sufficient clearance around the unit for proper airflow.
  • Use the provided mounting hardware (screws and anchors) to securely attach the inverter to a sturdy vertical surface. Refer to the dimensions in the specifications table for appropriate spacing.
Back view of the PowMr inverter showing mounting holes.

Image: Back panel of the inverter indicating mounting points.

5.2 Wiring Connections

Carefully follow the wiring diagrams provided in the full user manual for your specific model. The general connection points are:

  • Battery Connection: Connect the battery bank to the DC input terminals (NEG and POS). Ensure correct polarity. The unit includes a battery fuse for safety.
  • PV Input: Connect your solar panel array to the PV input terminals. Observe the MPPT voltage range and maximum open circuit voltage specified for your model.
  • AC Input: Connect the AC grid or generator input to the AC input terminals (L, N, G).
  • AC Output: Connect your loads to the AC output terminals (L, N, G).
  • Communication Ports: Connect RS232 or RS485 cables for external communication and BMS integration if required.
Rear view of PowMr solar inverter showing AC input, AC output, PV input, and DC battery connection points.

Image: Detailed view of the inverter's connection terminals for AC input, AC output, PV input, and DC battery.

Always double-check all connections for tightness and correct polarity before powering on the unit.

6. Operating Instructions

Once all connections are securely made and verified, you can proceed with operating the inverter.

6.1 Powering On/Off

  • To Power On: Ensure all external power sources (PV, AC grid) are connected. Switch on the DC breaker for the battery, then switch on the AC input breaker. Finally, press the power button on the inverter.
  • To Power Off: First, disconnect the AC output loads. Then, switch off the AC input breaker, followed by the PV input (if applicable), and finally the DC battery breaker. Press the power button to turn off the inverter.

6.2 Display and Controls

The inverter features a display screen and control buttons (ESC, UP, DOWN, ENTER) for monitoring system status and configuring settings. Refer to the detailed user manual for navigation and parameter adjustments.

Front view of PowMr solar inverter showing the display screen and control buttons.

Image: Front panel of the inverter with the display and control interface.

6.3 Operating Modes

The PowMr POW-RELAB series can operate in various modes, including:

  • Inverter Mode: Converts DC power from batteries to AC power for loads.
  • Charger Mode: Charges batteries using power from PV panels or the AC grid.
  • Bypass Mode: Supplies AC power directly from the grid to the loads, bypassing the inverter.

You can prioritize power sources (e.g., Solar first, Utility first, SBU priority) and charging sources through the unit's settings menu. Consult the full manual for detailed configuration options.

7. Maintenance

Regular maintenance helps ensure the longevity and optimal performance of your solar inverter.

  • Regular Inspection: Periodically inspect the inverter for any visible damage, loose connections, or signs of overheating.
  • Cleaning: Keep the inverter's ventilation openings clear of dust and debris to ensure proper cooling. Use a soft, dry cloth for cleaning the exterior. Do not use liquid cleaners.
  • Battery Check: If using lead-acid batteries, regularly check their water levels and terminal connections. For all battery types, monitor their health and performance through the inverter's display or communication software.
  • Firmware Updates: Check the manufacturer's website for any available firmware updates to ensure your inverter has the latest features and bug fixes.

Always disconnect all power sources before performing any cleaning or maintenance.

8. Troubleshooting

If you encounter issues with your PowMr POW-RELAB inverter, refer to the following general troubleshooting steps. For specific error codes and advanced diagnostics, consult the comprehensive user manual.

  • No Power/Display Off: Check all power connections (battery, AC input). Ensure the DC battery breaker and AC input breaker are on. Verify the power button is pressed.
  • No AC Output: Check if the inverter is in bypass mode. Verify battery voltage is sufficient. Check AC output breaker and connections to loads.
  • Battery Not Charging: Check PV panel connections and ensure sufficient sunlight. Verify AC input is present if charging from grid. Check charging settings on the inverter.
  • Overload Warning: Reduce the load connected to the inverter. Check for short circuits in the load wiring.
  • High Temperature Warning: Ensure the inverter has adequate ventilation. Clean any dust from the vents. Reduce ambient temperature if possible.

If the problem persists after following these steps, contact technical support.

9. User Tips

  • Read the Manual: Always refer to the complete user manual for detailed installation, operation, and troubleshooting information specific to your model.
  • Monitor Performance: Regularly check the inverter's display for operational status, battery charge, and power flow to ensure optimal system performance.
  • Battery Management: Proper battery management, including selecting the correct battery type in the inverter settings and avoiding deep discharges, will significantly extend battery lifespan.

10. Warranty and Support

For warranty information, please refer to the warranty card included with your product or contact your point of purchase. PowMr provides lifetime online technical support through various channels such as WhatsApp, Skype, Wechat, and Email. For any issues after delivery, video call support is available.

Contact Support:

  • WhatsApp: +86 19176692407
  • Email: maoyishunda@gmail.com

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.