1. Product Overview
The Jikong Smart BMS V19 is an intelligent battery management system designed for large capacity series lithium battery packs. It features voltage acquisition, high current active balancing, overcharge, over-discharge, overcurrent, over-temperature protection, coulomb metering, Bluetooth communication, and host computer monitoring.
This BMS is suitable for various battery types including LiFePo4, Li-ion, and LTO, supporting 8S to 16S configurations. It incorporates energy transfer active balancing technology with independent intellectual property rights, achieving a maximum continuous 1A/2A balance current. This technology ensures battery consistency, improves cruising range, and delays battery aging.
The system includes a mobile APP for Android and iOS, allowing users to monitor battery status, modify parameters, and control charge/discharge switches via Bluetooth. The compact design, simple operation, and comprehensive functions make it ideal for high-power energy storage, base station backup power, and solar power applications.
2. Key Features
- Active Equalization: 1A/2A continuous balancing current with supercapacitor as medium.
- Voltage Range: Single cell voltage range 1V~5V, equalization accuracy ±5mV.
- Protection Functions: Overcharge, over-discharge, overcurrent, over-temperature, low-temperature, and short-circuit protection.
- Communication: Bluetooth, RS232, RS485, CAN, UART.
- Monitoring: Mobile APP (Android/iOS) and PC software for real-time battery status and parameter adjustment.
- Display: Optional 3.2-inch display for convenient viewing of battery information.
- Heating Function: Standard feature to prevent low-temperature charging/discharging issues.
- Dry Contact Function: Two dry contacts for controlling external devices like alarms or fans.
- Emergency Switch: Provides 30 minutes of charge/discharge operation during critical events.
- Intelligent Sleep: Reduces BMS power consumption during standby.
- Charge Current Limiting: Limits charging current to 10A during overcurrent conditions.
3. Installation and Wiring
3.1. Product Appearance and Dimensions
The Jikong Smart BMS V19 consists of the main BMS board, an interface board, and an optional 3.2-inch display. The main BMS board dimensions are 300mm × 100mm × 24mm.


3.2. Wiring Method
The BMS is suitable for 7-16 series lithium battery packs. The specific wiring method depends on the number of cells in your battery pack. Always ensure all cables are connected correctly before powering on the BMS.
- Connect all the cables.
- Insert the cable into the BMS.
- Connect the B-line and the P-line to the battery.
- Important: If there are two B8 cables, only the first B8 line needs to be connected. The second B8 cable is not required.


3.3. Interface Definitions
The interface board provides connections for LED indicators, reset switch, DIP switch, dry contact, and communication functions.

Key Interfaces:
- P1 (Interface Board Interface): Connects to the main BMS board.
- P4 (UART Display Interface): For connecting the 3.2-inch display. Pins include K- (activation signal negative), K+ (activation signal positive), GND (negative terminal), RX (UART RX, 5V), TX (UART TX, 5V), VCC (display power output).
- P5 (Display Interface): Similar to P4, also for display connection, including RS485-A and RS485-B for display communication.
- P6, P7, P8, P9 (Acquisition Interface): For connecting sampling lines (B0-B16) and NTC temperature probes (NT1, NT2, NT3, NT4).
- P10 (Heating Interface): For connecting the heater element (HT-).
- P11 (Power Input): For positive power input (B+).
- P- (Load Output Negative): Connects to external load or negative terminal of charger.
- B- (Battery Negative): Connects to the negative battery terminal.
DIP Switch Settings for Parallel Function:
When using multiple BMS units in parallel, each unit needs a unique address (0-15) set via the DIP switches. Address 0 is for the host BMS, and 1-15 are for slave BMS units.
| Address | Switch 1 | Switch 2 | Switch 3 | Switch 4 |
|---|---|---|---|---|
| 0 (Host) | OFF | OFF | OFF | OFF |
| 1 (Slave) | ON | OFF | OFF | OFF |
| 2 (Slave) | OFF | ON | OFF | OFF |
| ... | ... | ... | ... | ... |
| 15 (Slave) | ON | ON | ON | ON |
4. Operation Instructions
4.1. Device Activation
Before activating the protection board, ensure all balance cables are properly connected and the P- and B- lines are correctly wired. Verify the protection board is securely fixed to the battery cells. Incorrect connection can lead to abnormal operation or damage.
The BMS does not have a physical power-on switch. It is designed for charging activation. After battery assembly, connect a charger (with voltage 2V higher than battery voltage) to activate the BMS. Alternatively, if you have the display and button, insert the cable into the display interface and press the button to activate.
4.2. Mobile APP and PC Software
The Jikong Smart BMS V19 can be monitored and configured via a mobile APP (Android/iOS) or PC software. The APP allows real-time viewing of battery status, modification of parameters, and control of charge/discharge switches.


To install the mobile APP, scan the QR code below. Android Version 7 or higher is required.

4.3. Parameter Settings
Parameters such as balance trigger voltage difference, continuous charging/discharging current, and protection thresholds can be adjusted via the APP. Always refer to the detailed parameter setting instructions within the APP or PC software before making changes.
4.4. Parallel Function
The parallel function allows simultaneous monitoring of multiple BMS units via an upper computer using the RS485 bus. This requires a USB to RS485 serial port cable and the Jikong upper computer software. Up to 16 BMS units are supported in parallel.

5. Protection and Maintenance
5.1. Overcharge and Over-discharge Protection
The BMS provides standard overcharge and over-discharge protection. Users can set single cell overcharge/recovery voltages and undervoltage/recovery voltages via the APP. When any cell exceeds the set overcharge voltage during charging, the BMS will stop charging. Similarly, if any cell drops below the undervoltage threshold during discharge, the BMS will stop discharging to protect the battery.
5.2. Overcurrent Protection
Charge and discharge overcurrent protection is standard. Users can set continuous charge/discharge currents and delay/release times via the APP. If the current exceeds the set value for the specified delay, the BMS will trigger protection and stop the operation.
5.3. Temperature Protection
Overtemperature and low-temperature protection for both charging and discharging are included. Users can set temperature thresholds via the APP. The BMS will stop operations if temperatures fall outside the safe range and resume when they return to normal. For extremely cold environments, using the heating function is recommended.
5.4. Short Circuit Protection
The BMS features short-circuit protection. While the trigger current is not user-settable, delay and recovery times can be adjusted via the APP. If a short circuit occurs, the BMS will cut off the circuit and resume after the recovery time. Adjusting the delay time can help prevent false triggers from high instantaneous currents during connection.
6. Troubleshooting
- Device Not Activating: Ensure all balance cables are correctly connected, and P- and B- lines are secure. Activate by connecting a charger with a voltage 2V higher than the battery, or by pressing the button on the optional display.
- Abnormal Readings/Behavior: Check all wiring for loose connections or incorrect polarity. Verify parameter settings in the APP.
- Over-protection Triggers: Review the set thresholds for overcharge, over-discharge, overcurrent, and temperature in the APP. Adjust if necessary, ensuring they match your battery specifications and usage.
- Short Circuit Issues: If short circuit protection triggers frequently, consider increasing the short circuit protection delay time in the APP, especially if connecting loads with high inrush current.
- Communication Problems: For parallel systems, ensure each BMS has a unique DIP switch address (0-15). Check RS485/CAN wiring and baud rates.
- Emergency Switch Use: In critical situations (over-temperature, over-discharge, over-charge, cell string drop), activate the emergency switch via the BMS control page in the APP. This provides 30 minutes of operation to allow for safe handling.
7. Specifications
| Technical Index | JK-PB1A16S10P | JK-PB1A16S15P | JK-PB2A16S15P | JK-PB2A16S20P | JK-PB2A16S30P |
|---|---|---|---|---|---|
| Number of Battery Strings (Li-ion) | 7S-16S | ||||
| Number of Battery Strings (LiFePo4) | 8S-16S | ||||
| Number of Battery Strings (LTO) | 14S-16S | ||||
| Balance Method | Active Balance (Full State On) | ||||
| Balance Current | 1A | 1A | 2A | 2A | 2A |
| Continuous Discharge Current | 100A | 150A | 150A | 200A | 300A |
| Maximum Discharge Current (MAX 2min) | 100A | 150A | 150A | 200A | 300A |
| Overcurrent Protection (ADJ) | 200A | 300A | 300A | 350A | 600A |
| Other Interfaces (Default) | RS485/232/CAN/UART | ||||
| Supply Voltage | 20-70V | ||||
| Wiring Output | Common Port | ||||
| Single Cell Voltage Range | 1-5V | ||||
| Voltage Acquisition Accuracy | ±5mV | ||||
| Overcharge Protection Voltage | 1.2-4.35V Adjustable | ||||
| Overcharge Release Voltage | 1.2-4.35V Adjustable | ||||
| Overcurrent Defect Delay | 2-120S Adjustable | ||||
| Over Discharge Protection Voltage | 1.2-4.35V Adjustable | ||||
| Quantity of Temperature Detection | 4 | ||||
| Temp Protection | Yes | ||||
| Short Circuit Protection | Yes | ||||
| Coulomb Counter | Yes | ||||
| Bluetooth Function | Support for Android/iOS/Harmony | ||||
| Parallel charging current limiting | 10A | ||||
| Address dial switch | 4 | ||||
| DRY Contact | 2 | ||||

8. User Tips
- Initial Setup: Always double-check all wiring, especially balance leads and main power connections, before applying power to prevent damage.
- APP Customization: Take advantage of the mobile APP to fine-tune protection parameters (overcharge, over-discharge, overcurrent, temperature) to perfectly match your specific battery chemistry and capacity.
- Cold Weather Operation: If operating in low-temperature environments, utilize the built-in heating function to maintain optimal battery performance and longevity.
- Parallel System Management: When using multiple BMS units in parallel, ensure each unit has a unique address set via the DIP switches for proper communication and monitoring through the host computer software.
- Firmware Updates: Regularly check for and install any available firmware updates for the BMS and its associated APP/PC software to ensure optimal performance and access to new features.
9. Warranty and Support
This product is manufactured by Chengdu Jikong Technology Co., Ltd. For technical support, warranty claims, or further inquiries, please contact the manufacturer or your point of purchase. Ensure you retain your purchase records for any warranty-related services.