PowMr POW-48140A

Contents

PowMr MPPT 140A Solar Charge Controller

Model: POW-48140A

User Manual

1. About This Manual

1.1 Purpose

This manual describes the assembly, installation, operation, and troubleshooting of this unit. Please read this manual carefully before installations and operations. Keep this manual for future reference.

1.2 Scope

This manual provides safety and installation guidelines as well as information on tools and wiring.

2. Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
  2. CAUTION – To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
  3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  4. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION - Only qualified personnel can install this device with battery.
  6. NEVER charge a frozen battery.
  7. For optimum operation of this charger, please follow required spec to select appropriate cable size. It's very important to correctly operate this charger.
  8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
  9. Please strictly follow installation procedure when you want to disconnect DC terminals. Please refer to INSTALLATION section of this manual for the details.
  10. One piece of 150A fuse is provided as over-current protection for the battery supply.
  11. NEVER cause DC input short circuited.
  12. Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this charger back to local dealer or service center for maintenance.

3. Introduction

This is a solar charger. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current.

3.1 Features

  • Configurable battery charging current based on applications via LCD setting
  • Over temperature protection
  • Smart battery charger design for optimized battery performance
  • Cold start function

3.2 Basic System Architecture

The following illustration shows basic application for this solar charger.

  • PV modules
Diagram showing a solar panel connected to the MPPT solar charge controller, which then connects to external battery packs.
Figure 1: Hybrid Power System Diagram

3.3 Product Overview

The product features an LCD display, charging indicator, fault indicator, and function buttons. Connections include PV input, ground connection, and battery input. An anti-dust kit is also integrated.

Detailed view of the solar charge controller showing its LCD display, indicators, function buttons, and connection ports labeled PV input, ground connection, and battery input.
Product Overview with labeled components

4. Setup (Installation)

4.1 Unpacking and Inspection

Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the unit and a user manual.

4.2 Preparation

Before connecting all wirings, please take off the bottom cover by removing two screws.

4.3 Mounting the Unit

Consider the following points before selecting where to install:

  1. Do not mount the charger on flammable construction materials.
  2. Mount on a solid surface.
  3. Install this charger at eye level in order to allow the LCD display to be read at all times.
  4. For proper air circulation to dissipate heat, allow a clearance of approx. 20 cm to the side and approx. 50 cm above and below the unit.
  5. The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
  6. The recommended installation position is to be adhered to the wall vertically.
  7. Be sure to keep other objects and surfaces to guarantee sufficient heat dissipation and to have enough space for removing wires.

SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

Install the unit by screwing two screws. It's recommended to use M6 screws.

5. Connection

5.1 Battery Connection

Recommended battery cable size:

ModelWire SizeCable(mm²)Torque value (max)
24V/140A1 x 2AWG252 Nm
48V/140A

CAUTION

  • For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between battery and charger. It may not be requested to have a disconnect device in some applications, however, it's still requested to have over-current protection installed. Please refer to typical amperage in above table as required fuse or breaker size.

WARNING

  • All wiring must be performed by a qualified personnel.
  • It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable.

Please follow below steps to implement battery connection:

  1. Remove insulation sleeve 18 mm for positive and negative conductors.
  2. Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
  3. Connect all battery packs as below chart.
Diagram showing battery connection for 24V and 48V systems, indicating positive and negative terminals.
Battery Connection Diagram

4. Insert the battery wires flatly into battery connectors of charger and make sure the bolts are tightened with torque of 2 Nm in clockwise direction. Make sure polarity at both the battery and the charge is correctly connected and conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.

WARNING

  • Installation must be performed with care due to high battery voltage in series.

CAUTION

  • Before making the final DC connection or closing DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative.

5.2 PV Connection

Recommended PV cable size:

ModelWire SizeCable(mm²)Torque value (max)
24V/140A1 x 12AWG41.2 Nm
48V/140A

CAUTION

  • Before connecting to PV modules, please install separately a DC circuit breaker between charger and PV modules.

WARNING

  • It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size.

PV Module Selection:

When selecting proper PV modules, please be sure to consider below parameters:

  1. Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of charger.
  2. Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.
Diagram showing solar panel specifications and connection to the solar charge controller. Max PV Array Power: 6500W, Max PV Array Open Circuit Voltage: 500VDC, PV Array MPPT Voltage Range: 60-450VDC, PV Wire Size: 12AWG.
PV Panel Specifications and Connection

PV Module Wire Connection:

Please follow below steps to implement PV module connection:

  1. Remove insulation sleeve 10 mm for positive and negative conductors.
  2. Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
  3. Check correct polarity of wire connection from PV modules and PV input connectors. Then, connect positive pole (+) of connection wire to positive pole (+) of PV input connector. Connect negative pole (-) of connection wire to negative pole (-) of PV input connector. Recommended tool: 4mm blade screwdriver.

5.3 Final Assembly

After connecting all wirings, please put the bottom cover back by screwing two screws.

Diagram showing the re-attachment of the bottom cover after wiring connections.
Final Assembly: Attaching the bottom cover

6. Operating

6.1 Operation and Display Panel

The operation and display panel is on the front of the charger. It includes two indicators, four function keys, and an LCD display, indicating the operating status and PV power information.

Close-up of the LCD screen and control buttons (ESC, UP, DOWN, ENTER) on the solar charge controller.
LCD Display and Function Keys

LED Indicators:

LED IndicatorColorMessages
CHGGreenSolid On: Battery is fully charged
GreenFlashing: Battery is charging.
FAULTRedSolid On: Fault occurs in the charger
RedFlashing: Warning condition occurs in the charger

Function Keys:

Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

6.2 LCD Setting

After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Press the "DOWN" button to select setting programs. Then, press the "ENTER" button to confirm the selection or press the "ENTER" button a second time to exit.

Key settings include:

  • Program 00: Exit setting mode (Options: Escape, One-button restore setting options)
  • Program 02: Maximum charging current (Range: 10-140A, increment 10A)
  • Program 05: Battery type (Options: AGM, Flooded, USE (User-Defined). If User-Defined, battery charge voltage can be set in programs 26, 27, 29.)
  • Program 07: Auto restart when over temperature occurs (Options: Restart disable, Restart enable)
  • Program 26: Bulk charging voltage (C.V voltage) (24V default: 28.2V, 48V default: 56.4V)
  • Program 27: Floating charging voltage (If User-Defined, range 25.0V-29.5V for 24V, 48.0V-59.0V for 48V. Increment 0.1V.)
  • Program 30: Battery equalization (Options: Battery equalization, Battery equalization disable (default). If Flooded or User-Defined, this program can be set up.)
  • Program 31: Battery equalization voltage (Range 25.0V-29.5V for 24V, 48.0V-59.0V for 48V. Increment 0.1V.)
  • Program 33: Battery equalized time (Range: 5-900min, increment 5min. Default: 60min)
  • Program 34: Battery equalized timeout (Default: 120min)
  • Program 35: Equalization interval (Range: 0-90 days, increment 1 day. Default: 30 days)
  • Program 36: Equalization activated immediately (Options: Enable, Disable. If enabled, activates equalization immediately. If disabled, waits for next scheduled equalization.)
  • Programs 81-85: Year, Month, Day, Hour, Minute set
  • Program 86: Clean Energy (Options: ENABLE, DISABLE)

6.3 Display

The LCD display information will be switched in turns by pressing the "UP" or "DOWN" key. The selectable information is switched as below order: PV voltage, charging current, charging power, battery voltage, main CPU Version.

Information that can be displayed includes:

  • Version number
  • PV voltage
  • PV current
  • PV temperature/PV power
  • Charge current/Battery voltage
  • Charge power
  • Daily power generation
  • Monthly power generation
  • Gross generation
  • Date and Time

7. Battery Equalization Description

Equalization function is added into the charge controller. It reverses the buildup of negative chemical effects like stratification, a condition where acid concentration is greater at the bottom of the battery than at the top. Equalization also helps to remove sulfate crystals that might have built up on the plates. If left unchecked, this condition, called sulfation, will reduce the overall capacity of the battery. Therefore, it's recommended to equalize the battery periodically.

How to Apply Equalization Function

You must enable the battery equalization function in monitoring LCD setting program 05 first. Then, you may apply this function in the device by either one of the following methods:

  1. Setting equalization interval in program 35.
  2. Active equalization immediately in program 36.

When to Equalize

In the float stage, when the setting equalization interval (battery equalization cycle) is arrived, or equalization is active immediately, the controller will start to enter the Equalize stage.

Graph illustrating the three-stage charging process: Boost Charge, Bulk Charge, Float Charge, and Equalization Charge, showing how battery voltage changes over time.
Three-Stage Charging Cycle with Equalization

Equalize Charging Time and Timeout

In the Equalize stage, the controller will supply power to charge the battery as much as possible until the battery voltage raises to the battery equalization voltage. Then, constant-voltage regulation is applied to maintain battery voltage at the battery equalization voltage. The battery will remain in the Equalize stage until the setting battery equalized time is arrived.

However, in the Equalize stage, when battery equalized time is expired and battery voltage doesn't rise to the battery equalization voltage point, the charge controller will extend the battery equalized time until battery voltage achieves battery equalization voltage. If battery voltage is still lower than battery equalization voltage when battery equalized timeout setting is over, the charge controller will stop equalization and return to the float stage.

Compatible Battery Types

The controller is compatible with various battery types, including Lead Acid and Lithium batteries.

Table showing supported battery types: Sealed (default), GEL, FLD for Lead Acid, and various LiFePO4 and Li(NiCoMn)O2 types for Lithium batteries, plus User-Defined.
Supported Battery Types

8. Maintenance

8.1 Overview of Anti-Dust Kit

Every charger is already installed with an anti-dust kit from the factory. The charger will automatically detect this kit and activate an internal thermal sensor to adjust the internal temperature. This kit also keeps dust from your charger and increases product reliability in harsh environments.

8.2 Clearance and Maintenance for Anti-Dust Kit

Step 1: Please loosen the screw in a counterclockwise direction on the top of the charger.

Diagram showing how to loosen screws to remove the dust filter cover from the solar charge controller.
Step 1: Loosening the screw for dust filter access

Step 2: Then, the dustproof case can be removed, and the air filter foam taken out as shown below.

Diagram showing the removal of the dustproof case and air filter foam from the solar charge controller.
Step 2: Removing the dustproof case and air filter foam

Step 3: Clean the air filter foam and dustproof case. After cleaning, re-assemble the dust-kit back to the charger.

NOTICE:

The anti-dust kit should be cleaned from dust every one month.

9. Troubleshooting

9.1 Fault Reference Code

Fault CodeFault EventIcon on
01Fan is locked when charger is off.ERROR
02Over temperatureERROR
03Battery voltage is too highERROR
08Bus voltage is too highERROR
09Bus soft start failedERROR
51Over current or surgeI ERROR
52Bus voltage is too lowERROR
57Current sensor failedERROR
59PV voltage is over limitationERROR

9.2 Warning Indicator

Warning CodeWarning EventAudible AlarmIcon flashing
E9Battery equalizationNoneE9®
6PBattery is not connectedNone6P

9.3 Troubleshooting Table

ProblemLCD/LED/BuzzerExplanation / Possible CauseWhat to do
Unit shuts down automatically during startup process.LCD/LEDs and buzzer will be active for 3 seconds and then complete off.The battery voltage is too low (<1.91V/Cell)1. Re-charge battery.
2. Replace battery.
No response after power on.No indication.1. The battery voltage is far too low. (<1.4V/Cell)
2. Internal fuse tripped.
1. Contact repair center for replacing the fuse.
2. Re-charge battery.
3. Replace battery.
Fault code 02Internal temperature of charger component is over 70°C.Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.
Battery is over-charged.Return to repair center.
Red LED is on.Fault code 03The battery voltage is too high.Check if spec and quantity of batteries are meet requirements
Fault code 01Fan faultReplace the fan.
Fault code 52Bus voltage is too low.Restart the unit, if the error happens again, please return to repair center.

10. Specifications

MPPT Solar Charging Mode

MODEL24V48V
Max. PV Array Power4200W6500W
Nominal PV Voltage180Vdc280Vdc
PV Array MPPT Voltage Range: 60Vdc~450Vdc
Max. PV Array Open Circuit Voltage: 500Vdc
Max Charging Current: 140Amp

Charging Curve

The charging curve illustrates the battery voltage and charging current behavior during different charging stages: Bulk (Constant Current), Absorption (Constant Voltage), and Maintenance (Floating).

Physical Specifications

ParameterValue
Dimension435×310×180mm
Weight6.5kg

11. Warranty and Support

For support and inquiries, please contact:

SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD

  • Tel/Fax: +86755-28219903
  • Email: support@powmr.com
  • Web: www.powmr.com
  • Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China

A PDF version of this user manual is available for download. Please refer to the official product page or contact support for the link: User manual (PDF)

12. Wiring Guide Video

Watch this official video for a step-by-step guide on wiring the PowMr POW-48140A Solar Charge Controller.

POW-48140A Solar Charge Controller Wiring Guide

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.