1. Introduction
The NJTY T21L is a high-precision digital multimeter designed for a wide range of electrical measurements. It features True RMS measurement, inductance and capacitance measurement capabilities, Non-Contact Voltage (NCV) detection, and an automatic shutdown function to conserve battery life. This manual provides detailed instructions for safe and effective use of your device.

2. Safety Information
Please read and understand all safety information before operating this multimeter. Failure to follow these instructions may result in electric shock, fire, or damage to the meter or the equipment under test.
- Always ensure the meter is in the correct function and range for the measurement being performed.
- Do not apply more than the rated voltage, as marked on the meter, between the terminals or between any terminal and ground.
- Use extreme caution when working with voltages above 60V DC or 30V AC RMS, as these pose a shock hazard.
- Before making resistance, capacitance, or diode measurements, disconnect power to the circuit and discharge all high-voltage capacitors.
- Replace the battery as soon as the low battery indicator appears to ensure accurate readings.
- Do not operate the meter if it appears damaged or if the case is open.
- Always use the appropriate input terminals for the measurement function.
3. Package Contents
Verify that all items are present in your package:
- NJTY T21L Digital Multimeter
- Test Leads (Red and Black)
- Temperature Probe
- User Manual

4. Product Overview
Familiarize yourself with the components and controls of your NJTY T21L Multimeter:

- Display: Digital display for readings.
- Function Knob: Rotary switch to select measurement functions.
- HOLD Button: Freezes the current reading on the display.
- FUNC/Hz Button: Toggles between functions within a mode (e.g., AC/DC, Frequency/Duty Cycle) or activates the buzzer indicator light.
- Flashlight/Backlight Button: Activates the built-in flashlight and display backlight.
- NCV Sensing Area: Top part of the meter for non-contact voltage detection.
- NCV Indicator Light: Illuminates during NCV detection.
- Input Terminals:
- COM: Common terminal for all measurements (black test lead).
- VΩmAHz°C: Input for voltage, resistance, capacitance, frequency, temperature, diode, and continuity measurements (red test lead).
- 10A: Input for high current measurements (red test lead).
5. Setup
5.1 Battery Installation
The NJTY T21L Multimeter requires 3 AAA batteries (not included) for operation.
- Ensure the multimeter is turned OFF.
- Locate the battery compartment on the back of the device.
- Use a screwdriver to open the battery compartment cover.
- Insert 3 AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- Replace the battery compartment cover and secure it with the screw.

5.2 Initial Power-On
Turn the function knob from the OFF position to any desired measurement function to power on the device. The display will illuminate, and the meter will be ready for use.
6. Operating Modes
The NJTY T21L Multimeter offers various measurement functions. Always ensure the correct function is selected and test leads are connected to the appropriate terminals.
6.1 DC Voltage Measurement (V=)
- Turn the function knob to the 'V=' position.
- Connect the black test lead to the COM terminal and the red test lead to the VΩmAHz°C terminal.
- Connect the test leads in parallel to the DC voltage source or component you wish to measure.
- Read the voltage value on the display.

6.2 AC Voltage Measurement (V~)
- Turn the function knob to the 'V~' position.
- Connect the black test lead to the COM terminal and the red test lead to the VΩmAHz°C terminal.
- Connect the test leads in parallel to the AC voltage source or component.
- Read the voltage value on the display.

6.3 Resistance Measurement (Ω)
- Turn the function knob to the 'Ω' position.
- Connect the black test lead to the COM terminal and the red test lead to the VΩmAHz°C terminal.
- Ensure the circuit is de-energized before connecting the test leads across the component.
- Read the resistance value on the display.

6.4 Capacitance Measurement (F)
- Turn the function knob to the 'F' position.
- Connect the black test lead to the COM terminal and the red test lead to the VΩmAHz°C terminal.
- Ensure the capacitor is fully discharged before connecting the test leads.
- Connect the test leads across the capacitor.
- Read the capacitance value on the display.

6.5 Inductance Measurement (H)
- Turn the function knob to the 'L' position.
- Connect the black test lead to the COM terminal and the red test lead to the VΩmAHz°C terminal.
- Connect the test leads across the inductor.
- Read the inductance value on the display.

6.6 Frequency Measurement (Hz)
- Turn the function knob to the 'Hz%' position.
- Connect the black test lead to the COM terminal and the red test lead to the VΩmAHz°C terminal.
- Connect the test leads in parallel to the circuit where you want to measure frequency.
- Read the frequency value on the display.

6.7 Temperature Measurement (°C/°F)
- Turn the function knob to the '°C/°F' position.
- Connect the temperature probe to the VΩmAHz°C and COM terminals, observing polarity.
- Place the tip of the temperature probe on or near the object whose temperature you wish to measure.
- Read the temperature value on the display. Use the FUNC/Hz button to switch between Celsius and Fahrenheit if needed.

6.8 Diode Test
- Turn the function knob to the diode symbol position.
- Connect the black test lead to the COM terminal and the red test lead to the VΩmAHz°C terminal.
- Connect the red test lead to the anode and the black test lead to the cathode of the diode.
- Read the forward voltage drop on the display. Reverse the leads to check for open circuit (OL).

6.9 Continuity Test
- Turn the function knob to the continuity symbol position.
- Connect the black test lead to the COM terminal and the red test lead to the VΩmAHz°C terminal.
- Connect the test leads across the circuit or component.
- If continuity exists (resistance below a certain threshold), the buzzer will sound, and the indicator lamp will light up.

6.10 Non-Contact Voltage (NCV) Detection
- Turn the function knob to the 'NCV' position.
- Move the top part of the multimeter (NCV sensing area) close to the conductor you want to test for AC voltage.
- The NCV indicator light will illuminate, and the buzzer will sound with increasing frequency as the meter gets closer to the AC voltage source.

6.11 Flashlight and Backlight
Press the Flashlight/Backlight button to turn on the built-in flashlight. Press it again to turn on the display backlight. Press a third time to turn both off.

6.12 Data Hold
Press the HOLD button to freeze the current reading on the display. Press it again to release the hold function and resume live readings.
7. Specifications
| Feature | Specification |
|---|---|
| Display Type | Digital Display (6000 counts) |
| Operating Mode | Auto Range |
| DC Voltage | Up to 600V |
| AC Voltage | Up to AC600V (True RMS) |
| DC Current | Up to 10A |
| AC Current | Up to 10A |
| Capacitance | Up to 100000uF |
| Inductance | Yes |
| Frequency | Yes |
| Temperature Measurement | Yes (with probe) |
| Non-Contact Voltage (NCV) | Yes |
| Battery Included | No (Requires 3x AAA batteries) |
| Overload Indication | OL |
| Conversion Rate | Approx. 3 times per second |
| Dimensions (L x W x H) | 147mm x 71mm x 45mm |
| DIY Supplies | Electrical |


8. Maintenance
8.1 Cleaning
To clean the meter, wipe the case with a damp cloth and a mild detergent. Do not use abrasives or solvents. Ensure the meter is completely dry before use.
8.2 Storage
When not in use for an extended period, remove the batteries to prevent leakage. Store the multimeter in a cool, dry place, away from direct sunlight and extreme temperatures.
8.3 Battery Replacement
When the low battery indicator appears on the display, replace the batteries immediately to ensure accurate measurements. Follow the steps in Section 5.1 for battery installation.
8.4 Fuse Replacement
If the current measurement function stops working, the fuse may need replacement. Refer to the specifications for the correct fuse type and rating. Fuse replacement should only be performed by qualified personnel.
9. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Meter does not power on | Dead or incorrectly installed batteries | Check battery polarity or replace batteries. |
| No reading or "OL" displayed | Incorrect range, open circuit, or overload | Ensure correct function/range. Check for open circuits. If overloaded, reduce input. |
| Inaccurate readings | Low battery, poor test lead connection, or external interference | Replace batteries. Ensure secure test lead connections. Move away from strong electromagnetic fields. |
| Current measurement not working | Blown fuse | Replace the fuse (refer to Section 8.4). |
10. User Tips
- Utilize the built-in magnet on the back of the multimeter to attach it to metal surfaces for hands-free operation.
- The automatic shutdown feature helps conserve battery life; remember to turn the knob to OFF when finished for extended storage.
- For quick checks of live wires without direct contact, the NCV function is highly convenient and a good safety measure.

11. Warranty and Support
This product comes with a standard manufacturer's warranty against defects in materials and workmanship. For warranty claims, technical support, or service inquiries, please contact your point of purchase or the manufacturer directly. Keep your purchase receipt as proof of purchase.