NJTY T21L

Contents

NJTY T21L Multifunctional Digital LCR Multimeter

User Manual

1. Introduction

The NJTY T21L is a high-precision digital multimeter designed for a wide range of electrical measurements. It features True RMS measurement, inductance and capacitance measurement capabilities, Non-Contact Voltage (NCV) detection, and an automatic shutdown function to conserve battery life. This manual provides detailed instructions for safe and effective use of your device.

NJTY T21L Multimeter front view with key features
Front view of the NJTY T21L Multimeter, highlighting key features like True RMS, 10000uF capacitance, inductance, NCV, and auto shutdown.

2. Safety Information

Please read and understand all safety information before operating this multimeter. Failure to follow these instructions may result in electric shock, fire, or damage to the meter or the equipment under test.

  • Always ensure the meter is in the correct function and range for the measurement being performed.
  • Do not apply more than the rated voltage, as marked on the meter, between the terminals or between any terminal and ground.
  • Use extreme caution when working with voltages above 60V DC or 30V AC RMS, as these pose a shock hazard.
  • Before making resistance, capacitance, or diode measurements, disconnect power to the circuit and discharge all high-voltage capacitors.
  • Replace the battery as soon as the low battery indicator appears to ensure accurate readings.
  • Do not operate the meter if it appears damaged or if the case is open.
  • Always use the appropriate input terminals for the measurement function.

3. Package Contents

Verify that all items are present in your package:

  • NJTY T21L Digital Multimeter
  • Test Leads (Red and Black)
  • Temperature Probe
  • User Manual
Package contents of NJTY T21L Multimeter
The package includes the multimeter, user manual, test leads, and a temperature probe.

4. Product Overview

Familiarize yourself with the components and controls of your NJTY T21L Multimeter:

NJTY T21L Multimeter front panel diagram
Front panel diagram of the multimeter, labeling all buttons, terminals, and the function knob.
  • Display: Digital display for readings.
  • Function Knob: Rotary switch to select measurement functions.
  • HOLD Button: Freezes the current reading on the display.
  • FUNC/Hz Button: Toggles between functions within a mode (e.g., AC/DC, Frequency/Duty Cycle) or activates the buzzer indicator light.
  • Flashlight/Backlight Button: Activates the built-in flashlight and display backlight.
  • NCV Sensing Area: Top part of the meter for non-contact voltage detection.
  • NCV Indicator Light: Illuminates during NCV detection.
  • Input Terminals:
    • COM: Common terminal for all measurements (black test lead).
    • VΩmAHz°C: Input for voltage, resistance, capacitance, frequency, temperature, diode, and continuity measurements (red test lead).
    • 10A: Input for high current measurements (red test lead).

5. Setup

5.1 Battery Installation

The NJTY T21L Multimeter requires 3 AAA batteries (not included) for operation.

  1. Ensure the multimeter is turned OFF.
  2. Locate the battery compartment on the back of the device.
  3. Use a screwdriver to open the battery compartment cover.
  4. Insert 3 AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
  5. Replace the battery compartment cover and secure it with the screw.
Battery compartment for 3 AAA batteries
Rear view of the multimeter showing the battery compartment for 3 AAA batteries.

5.2 Initial Power-On

Turn the function knob from the OFF position to any desired measurement function to power on the device. The display will illuminate, and the meter will be ready for use.

6. Operating Modes

The NJTY T21L Multimeter offers various measurement functions. Always ensure the correct function is selected and test leads are connected to the appropriate terminals.

6.1 DC Voltage Measurement (V=)

  1. Turn the function knob to the 'V=' position.
  2. Connect the black test lead to the COM terminal and the red test lead to the VΩmAHz°C terminal.
  3. Connect the test leads in parallel to the DC voltage source or component you wish to measure.
  4. Read the voltage value on the display.
Multimeter measuring DC voltage
Multimeter measuring DC voltage from a 9V battery.

6.2 AC Voltage Measurement (V~)

  1. Turn the function knob to the 'V~' position.
  2. Connect the black test lead to the COM terminal and the red test lead to the VΩmAHz°C terminal.
  3. Connect the test leads in parallel to the AC voltage source or component.
  4. Read the voltage value on the display.
Multimeter measuring AC voltage
Multimeter measuring AC voltage from a wall outlet.

6.3 Resistance Measurement (Ω)

  1. Turn the function knob to the 'Ω' position.
  2. Connect the black test lead to the COM terminal and the red test lead to the VΩmAHz°C terminal.
  3. Ensure the circuit is de-energized before connecting the test leads across the component.
  4. Read the resistance value on the display.
Multimeter performing resistance measurement
Multimeter performing a resistance measurement.

6.4 Capacitance Measurement (F)

  1. Turn the function knob to the 'F' position.
  2. Connect the black test lead to the COM terminal and the red test lead to the VΩmAHz°C terminal.
  3. Ensure the capacitor is fully discharged before connecting the test leads.
  4. Connect the test leads across the capacitor.
  5. Read the capacitance value on the display.
Multimeter performing capacitance measurement
Multimeter performing a capacitance measurement.

6.5 Inductance Measurement (H)

  1. Turn the function knob to the 'L' position.
  2. Connect the black test lead to the COM terminal and the red test lead to the VΩmAHz°C terminal.
  3. Connect the test leads across the inductor.
  4. Read the inductance value on the display.
Multimeter performing inductance measurement
Multimeter performing an inductance measurement on a transformer.

6.6 Frequency Measurement (Hz)

  1. Turn the function knob to the 'Hz%' position.
  2. Connect the black test lead to the COM terminal and the red test lead to the VΩmAHz°C terminal.
  3. Connect the test leads in parallel to the circuit where you want to measure frequency.
  4. Read the frequency value on the display.
Multimeter measuring frequency
Multimeter measuring frequency from a power outlet.

6.7 Temperature Measurement (°C/°F)

  1. Turn the function knob to the '°C/°F' position.
  2. Connect the temperature probe to the VΩmAHz°C and COM terminals, observing polarity.
  3. Place the tip of the temperature probe on or near the object whose temperature you wish to measure.
  4. Read the temperature value on the display. Use the FUNC/Hz button to switch between Celsius and Fahrenheit if needed.
Multimeter displaying temperature measurement
Multimeter displaying a temperature measurement using the included probe.

6.8 Diode Test

  1. Turn the function knob to the diode symbol position.
  2. Connect the black test lead to the COM terminal and the red test lead to the VΩmAHz°C terminal.
  3. Connect the red test lead to the anode and the black test lead to the cathode of the diode.
  4. Read the forward voltage drop on the display. Reverse the leads to check for open circuit (OL).
Multimeter performing diode measurement
Multimeter performing a diode test.

6.9 Continuity Test

  1. Turn the function knob to the continuity symbol position.
  2. Connect the black test lead to the COM terminal and the red test lead to the VΩmAHz°C terminal.
  3. Connect the test leads across the circuit or component.
  4. If continuity exists (resistance below a certain threshold), the buzzer will sound, and the indicator lamp will light up.
Multimeter performing continuity test
Multimeter performing a continuity test, showing the indicator lamp.

6.10 Non-Contact Voltage (NCV) Detection

  1. Turn the function knob to the 'NCV' position.
  2. Move the top part of the multimeter (NCV sensing area) close to the conductor you want to test for AC voltage.
  3. The NCV indicator light will illuminate, and the buzzer will sound with increasing frequency as the meter gets closer to the AC voltage source.
Multimeter demonstrating NCV detection
Multimeter demonstrating Non-Contact Voltage (NCV) detection near a power outlet.

6.11 Flashlight and Backlight

Press the Flashlight/Backlight button to turn on the built-in flashlight. Press it again to turn on the display backlight. Press a third time to turn both off.

Multimeter with flashlight activated
Multimeter with its built-in flashlight activated.

6.12 Data Hold

Press the HOLD button to freeze the current reading on the display. Press it again to release the hold function and resume live readings.

7. Specifications

FeatureSpecification
Display TypeDigital Display (6000 counts)
Operating ModeAuto Range
DC VoltageUp to 600V
AC VoltageUp to AC600V (True RMS)
DC CurrentUp to 10A
AC CurrentUp to 10A
CapacitanceUp to 100000uF
InductanceYes
FrequencyYes
Temperature MeasurementYes (with probe)
Non-Contact Voltage (NCV)Yes
Battery IncludedNo (Requires 3x AAA batteries)
Overload IndicationOL
Conversion RateApprox. 3 times per second
Dimensions (L x W x H)147mm x 71mm x 45mm
DIY SuppliesElectrical
Multimeter dimensions diagram
Dimensions of the NJTY T21L Multimeter.
Multimeter displaying general specifications
Additional specifications including conversion rate and overload indication.

8. Maintenance

8.1 Cleaning

To clean the meter, wipe the case with a damp cloth and a mild detergent. Do not use abrasives or solvents. Ensure the meter is completely dry before use.

8.2 Storage

When not in use for an extended period, remove the batteries to prevent leakage. Store the multimeter in a cool, dry place, away from direct sunlight and extreme temperatures.

8.3 Battery Replacement

When the low battery indicator appears on the display, replace the batteries immediately to ensure accurate measurements. Follow the steps in Section 5.1 for battery installation.

8.4 Fuse Replacement

If the current measurement function stops working, the fuse may need replacement. Refer to the specifications for the correct fuse type and rating. Fuse replacement should only be performed by qualified personnel.

9. Troubleshooting

ProblemPossible CauseSolution
Meter does not power onDead or incorrectly installed batteriesCheck battery polarity or replace batteries.
No reading or "OL" displayedIncorrect range, open circuit, or overloadEnsure correct function/range. Check for open circuits. If overloaded, reduce input.
Inaccurate readingsLow battery, poor test lead connection, or external interferenceReplace batteries. Ensure secure test lead connections. Move away from strong electromagnetic fields.
Current measurement not workingBlown fuseReplace the fuse (refer to Section 8.4).

10. User Tips

  • Utilize the built-in magnet on the back of the multimeter to attach it to metal surfaces for hands-free operation.
  • The automatic shutdown feature helps conserve battery life; remember to turn the knob to OFF when finished for extended storage.
  • For quick checks of live wires without direct contact, the NCV function is highly convenient and a good safety measure.
Multimeter with kickstand and magnets
Side view of the multimeter showing the kickstand and integrated magnets for attaching to metal surfaces.

11. Warranty and Support

This product comes with a standard manufacturer's warranty against defects in materials and workmanship. For warranty claims, technical support, or service inquiries, please contact your point of purchase or the manufacturer directly. Keep your purchase receipt as proof of purchase.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.