1. Introduction
This manual describes the assembly, installation, operation, and troubleshooting of the Daxtromn 10.2KW 48V Hybrid Solar Inverter. Please read this manual carefully before installations and operations and keep it for future reference. This inverter/charger is a multi-function unit combining inverter, solar charger, and battery charger functions to provide uninterruptible power support. Its comprehensive LCD display allows for user-configurable and easy-accessible button operation for settings such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.
1.1 Features
- Pure sine wave solar inverter (on/off Grid)
- Output power factor 1.0
- Configurable input voltage range for home appliances and personal computers via LCD setting
- Configurable battery charging current based on applications via LCD setting
- Configurable AC/Solar Charger priority via LCD setting
- Compatible with mains voltage or generator power
- Auto restart while AC is recovering
- Overload/ Over temperature/ short circuit protection
- Smart battery charger design for optimized battery performance
- Cold start function
- WIFI available for iOS and Android (optional)
- One-key restoration to factory settings
- Built-in Lithium battery automatic activation
- Built-in 160A MPPT solar charger
- High PV input voltage range (90~450VDC)
- Built-in anti-dust kit for harsh environments
- Touch button interface
- Dual output (2 AC Output function)
1.2 Basic System Architecture
The inverter can power various appliances in home or office environments, including motor-type appliances such as tube lights, fans, refrigerators, and air conditioners. The system can operate with solar power, a generator, or utility power, and can connect to external battery packs to power home appliances.

2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION: To reduce the risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce the risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION: Only qualified personnel can install this device with a battery.
- NEVER charge a frozen battery.
- For optimum operation, follow the required specifications to select appropriate cable sizes.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Strictly follow the installation procedure when disconnecting AC or DC terminals.
- One piece of 150A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations.
- NEVER cause AC output and DC input short circuits. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following the troubleshooting table, send this inverter/charger back to a local dealer or service center for maintenance.
- WARNING: Do NOT connect the second output to the grid, it will damage your inverter.
3. Product Overview

- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Touch Function buttons
- Power on/off switch
- AC input
- Main output
- Second output
- PV1 and PV2 input
- WIFI communication/RS-232 port
- Battery communication/RS-485 port
- Battery input
- Anti dust kit

4. Setup (Installation)
4.1 Unpacking and Inspection
Before installation, inspect the unit. Ensure nothing inside the package is damaged. The package should contain:
- The unit x 1
- User manual x 1
- Ring terminal x 1
- Mc4 terminal head x 2
4.2 Mounting the Unit
Consider the following points when selecting where to install the inverter:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level to allow the LCD display to be read at all times.
- For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm to the side and 50 cm above and below the unit.
- The ambient temperature should be between 0°C and 55°C for optimal operation.
- The recommended installation position is to adhere to the wall vertically.
- Ensure other objects and surfaces are left with enough space from the machine for adequate heat dissipation and room to remove wires.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Install the unit by screwing two screws. M4 or M5 screws are recommended.
4.3 Battery Connection
CAUTION:
- For safety and regulation compliance, install a separate DC over-current protector or disconnect device between the battery and inverter.
- All wiring must be performed by qualified personnel.
- Use appropriate cable for battery connection to reduce risk of injury.
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 8.2KW/10.2KW | 1 x 2AWG | 25 | 2 Nm |
Follow these steps for battery connection:
- Remove insulation sleeve 18 mm for positive and negative conductors.
- Suggest putting bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Connect all battery packs as shown in the diagram below.

- Insert the battery wires flatly into the inverter's battery connectors and ensure the bolts are tightened with a torque of 2 Nm in a clockwise direction. Verify polarity at both the battery and the inverter/charger.
WARNING: Shock Hazard. Installation must be performed with care due to high battery voltage in series.
CAUTION!! Before making the final DC connection or closing the DC breaker/disconnector, ensure positive (+) is connected to positive (+) and negative (-) to negative (-).
4.4 AC Input/Output Connection
CAUTION!!
- Before connecting to an AC input power source, install a separate AC breaker between the inverter and the AC input power source. The recommended spec of AC breaker is 63A for 8.2KW/10.2KW.
- There are two terminal blocks with "IN" and "OUT" markings. Do NOT mis-connect input and output connectors.
WARNING! All wiring must be performed by qualified personnel. Use appropriate cable for AC input connection.
| Model | Gauge | Cable (mm²) | Torque Value |
|---|---|---|---|
| 8.2KW/10.2KW | 10 AWG | 6 | 1.2 Nm |
Follow these steps to implement AC input/output connection:
- Before making AC input/output connection, open the DC protector or disconnector first.
- Remove insulation sleeve 10mm for six conductors. Shorten phase L and neutral conductor N by 3 mm.
- Insert AC input wires according to polarities indicated on the terminal block and tighten the terminal screws. Connect the PE protective conductor (yellow-green) first.
- Insert AC output wires according to polarities indicated on the terminal block and tighten the terminal screws.
- Ensure the wires are securely connected.
4.5 PV Connection
CAUTION:
- Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.
- Exceeding the maximum input voltage can destroy the unit. Check the system before wire connection.
WARNING! Use appropriate cable for PV module connection.
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 8.2KW/10.2KW | 1 x 10AWG | 6 | 1.2 Nm |
PV Module Selection
When selecting PV modules, consider these parameters:
- Open circuit Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than the min. battery voltage.
| Inverter Model | 8.2KW/10.2KW |
|---|---|
| Max. PV Array Open Circuit Voltage | 500Vdc |
| PV Array MPPT Voltage Range | 90Vdc~450Vdc |
For example, using 250Wp PV modules (Vmp: 30.1Vdc, Imp: 8.3A, Voc: 37.7Vdc, Isc: 8.4A, Cells: 60), recommended configurations are:
| Solar Input (Min in serial: 6 pcs, max. in serial: 13 pcs) | Q'ty of panels | Total input power |
|---|---|---|
| 6 pcs in serial | 6 pcs | 1500W |
| 8 pcs in serial | 8 pcs | 2000W |
| 12 pcs in serial | 12 pcs | 3000W |
| 13 pcs in serial | 13 pcs | 3250W |
| 12 pieces in serial and 3 sets in parallel | 36 pcs | 8200W |
| 10 pieces in serial and 4 sets in parallel | 40 pcs | 10200W |
PV Module Wire Connection
Step 1: Check the input voltage of PV array modules. The acceptable input voltage of the inverter is 120VDC - 500VDC. Ensure the maximum current load of each PV input connector is 10A.

4.6 Communication Connection
Wi-Fi Cloud Communication (Option)
Use the supplied communication cable to connect to the inverter and Wi-Fi module. Download the APP from the APP store and refer to the "Wi-Fi Plug Quick Installation Guideline" to set up the network and register. The inverter status will be shown via the mobile phone APP or a computer webpage.
Battery Communication
Communication between the battery and the inverter is achieved through the battery communication interface, allowing the inverter and the lithium battery to exchange information (Baud rate: 9600).

To communicate with the lithium battery BMS, press and hold the "ENTER" button for a long time, and set the battery type as "LIB-485" in program 05. Then select the matching battery protocol in Program 43.
CAUTION: When the battery type is set to "LIB-485", the setting items 12, 13, and 29 are displayed in percentage. The user cannot modify the maximum charging current. If communication fails, the inverter will cut off the output.
5. Operating Instructions
5.1 Power ON/OFF
Once the unit is properly installed and the batteries are connected, simply press the On/Off switch (located on the bottom of the case) to turn on the unit.
5.2 Operation and Display Panel
The operation and display panel is on the front of the inverter. It includes three indicators, four function keys, and an LCD display, indicating the operating status and input/output power information.

LED Indicator
| Indicator | Color | State | Messages |
|---|---|---|---|
| INV/AC | Green | Solid On Flashing | Output is powered by utility in Line mode. Output is powered by battery or PV in battery mode. |
| CHG | Green | Solid On Flashing | Battery is fully charged. Battery is charging. |
| FAULT | Red | Solid On Flashing | Fault occurs in the inverter. Warning condition occurs in the inverter. |
Function Keys
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
5.3 LCD Setting
After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Use the "UP" or "DOWN" button to select setting programs, then press "ENTER" to confirm or "ESC" to exit.
5.4 Operating Mode Description


5.5 Battery Equalization Description
The equalization function reverses the buildup of negative chemical effects like stratification and helps remove sulfate crystals. This process is recommended periodically to maintain battery capacity.
How to Apply Equalization Function
Enable battery equalization in LCD setting program 30. Then, apply it by either:
- Setting the equalization interval in program 35.
- Activating equalization immediately in program 36.
When to Equalize
In the float stage, when the set equalization interval is reached, or equalization is activated immediately, the controller will enter the Equalize stage.
Equalize Charging Time and Timeout
During the Equalize stage, the controller charges the battery until it reaches the equalization voltage. Constant-voltage regulation maintains this voltage. The battery remains in this stage until the set equalized time is reached. If the battery voltage doesn't reach the equalization point within the set time, the charge controller will extend the time. If it still doesn't reach the voltage after the timeout, the controller stops equalization and returns to the float stage.
5.6 Mains and Lithium Battery Activation Function
- After 90 seconds of mains power connection, the inverter connects to the mains and starts working.
- If the inverter is in lithium battery mode (item 05 is LIP or LIL), and the mains are connected but the battery is not, the mains activation function is automatically enabled.
6. Maintenance
6.1 Clearance and Maintenance for Anti-Dust Kit
Every inverter comes with an anti-dust kit installed from the factory. The inverter automatically detects this kit and adjusts its internal thermal sensor to regulate temperature. This kit prevents dust from entering the inverter, increasing product reliability in harsh environments.
- Loosen the screw in a counterclockwise direction on the top of the inverter.
- Remove the dustproof case and take out the air filter foam.
- Clean the air filter foam and dustproof case. After cleaning, re-assemble the dust-kit back to the inverter.
NOTICE: The anti-dust kit should be cleaned from dust every one month.
7. Troubleshooting
7.1 Fault Reference Code
| Fault Code | Fault Event | Icon on |
|---|---|---|
| 01 | Fan is locked when inverter is off. | 01 ERROR |
| 02 | Over temperature | 02 ERROR |
| 03 | Battery voltage is too high | 03 ERROR |
| 04 | Battery voltage is too low | 04 ERROR |
| 05 | Output short circuited or over temperature is detected by internal converter components. | 05 ERROR |
| 06 | Output voltage is too high. | 06 ERROR |
| 07 | Overload time out | 07 ERROR |
| 08 | Bus voltage is too high | 08 ERROR |
| 09 | Bus soft start failed | 09 ERROR |
| 51 | Over current or surge | 51 ERROR |
| 52 | Bus voltage is too low | 52 ERROR |
| 53 | Inverter soft start failed | 53 ERROR |
| 55 | Over DC voltage in AC output | 55 ERROR |
| 57 | Current sensor failed | 57 ERROR |
| 58 | Output voltage is too low | 58 ERROR |
| 59 | PV voltage is over limitation | 59 ERROR |
Battery Fault Codes (Lithium Battery Mode)
| Fault Code | Fault Event | Fault Condition |
|---|---|---|
| 02 | The battery temperature is too high | Lithium battery charging battery temperature ≥65°C; Discharge temperature of the lithium battery is higher than 70°C. |
| 03 | The battery voltage is too high | Lithium battery maximum single cell voltage >3.65V; Total voltage of lithium battery >54.6V (48V lithium battery). |
| 04 | The battery voltage is too low | Minimum voltage of a lithium battery cell <2.71V; Lithium battery total voltage <40.4V (48V lithium battery). |
7.2 Warning Indicator
| Warning Code | Warning Event | Audible Alarm | Icon flashing |
|---|---|---|---|
| 01 | Fan is locked when inverter is on. | Beep three times every second | 01 |
| 03 | Battery is over-charged | Beep once every second | 03 |
| 04 | Low battery | Beep once every second | 04 |
| 07 | Overload | Beep once every 0.5 second | 07 |
| 10 | Output power derating | Beep twice every 3 seconds | 10 |
| 15 | PV energy is low. | Beep twice every 3 seconds | 15 |
| E9 | Battery equalization | None | E9 |
| 6P | Battery is not connected | None | 6P |
Added Battery Warning Codes (Lithium Battery Mode)
| Warning Code | Warning Event | Warning Condition |
|---|---|---|
| 04 | The battery voltage is too low | Minimum voltage of a lithium battery cell <2.85V; Lithium battery total voltage <42V (48V lithium battery). |
| 05 | The battery voltage is too high | Lithium battery maximum single cell voltage >3.55V; Total voltage of lithium battery >54V (48V lithium battery). |
| 06 | The battery is low warning | Remaining battery capacity ≤10% |
7.3 General Troubleshooting
| Problem | LCD/LED/Buzzer | Explanation / Possible cause | What to do |
|---|---|---|---|
| Unit shuts down automatically during startup process. | LCD/LEDs and buzzer will be active for 3 seconds and then complete off. | The battery voltage is too low (<1.91V/Cell) | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | No indication. Input voltage is displayed as 0 on the LCD and green LED is flashing. | 1. The battery voltage is far too low. (<1.4V/Cell) 2. Internal fuse tripped. Input protector is tripped | 1. Contact repair center for replacing the fuse. 2. Re-charge battery. 3. Replace battery. Check if AC breaker is tripped and AC wiring is connected well. |
| Mains exist but the unit works in battery mode. | Green LED is flashing. | Insufficient quality of AC power. (Shore or Generator) | 1. Check if AC wires are too thin and/or too long. 2. Check if generator (if applied) is working well or if input voltage range setting is correct. (UPS/Appliance) |
| Green LED is flashing. | Set "Solar First" as the priority of output source. | Change output source priority to Utility first. | |
| When the unit is turned on, internal relay is switched on and off repeatedly. | LCD display and LEDs are flashing | Battery is disconnected. | Check if battery wires are connected well. |
| Fault code 07 | Overload error. The inverter is overload 110% and time is up. | Reduce the connected load by switching off some equipment. | |
| Fault code 05 | Output short circuited. | Check if wiring is connected well and remove abnormal load. | |
| Fault code 02 | Temperature of internal converter component is over 120°C. Internal temperature of inverter component is over 100°C. | Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. | |
| Buzzer beeps continuously and red LED is on. | Fault code 03 | Battery is over-charged. The battery voltage is too high. | Return to repair center. Check if spec and quantity of batteries are meet requirements. |
| Fault code 01 | Fan fault | Replace the fan. | |
| Fault code 06/58 | Output abnormal (Inverter voltage below than 190Vac or is higher than 260Vac) | 1. Reduce the connected load. 2. Return to repair center | |
| Fault code 08/09/53/57 | Internal components failed. | Return to repair center. | |
| Fault code 51 | Over current or surge. | Restart the unit, if the error happens again, please return to repair center. | |
| Fault code 52 | Bus voltage is too low. | ||
| Fault code 55 | Output voltage is unbalanced. |
8. Specifications

8.1 Line Mode Specifications
| Inverter Model | 8.2KW | 10.2KW |
|---|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) | |
| Nominal Input Voltage | 230Vac | |
| Low Loss Voltage | 170Vac±7V (UPS); 90Vac±7V (Appliances) | |
| Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliances) | |
| High Loss Voltage | 280Vac±7V | |
| High Loss Return Voltage | 270Vac±7V | |
| Max AC Input Voltage | 300Vac | |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) | |
| Low Loss Frequency | 40±1Hz | |
| Low Loss Return Frequency | 42±1Hz | |
| High Loss Frequency | 65±1Hz | |
| High Loss Return Frequency | 63±1Hz | |
| Output Short Circuit Protection | Circuit Breaker | |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) | |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) | |
8.2 Inverter Mode Specifications
| Inverter Model | 8.2KW | 10.2KW |
|---|---|---|
| Rated Output Power | 8.2KW | 10.2KW |
| Output Voltage Waveform | Pure Sine Wave | |
| Output Voltage Regulation | 230Vac±5% | |
| Output Frequency | 50Hz | |
| Peak Efficiency | 93% | |
| Overload Protection | 3s@≥150% load; 5s@101%~150% load | |
| Surge Capacity | 2* rated power for 5 seconds | |
| Nominal DC Input Voltage | 48Vdc | |
| Cold Start Voltage | 46.0Vdc | |
| Low DC Warning Voltage @load < 50% | 44.0Vdc | |
| Low DC Warning Voltage @load ≥ 50% | 42.0Vdc | |
| Low DC Warning Return Voltage @load < 50% | 45.0Vdc | |
| Low DC Warning Return Voltage @load ≥ 50% | 44.0Vdc | |
| Low DC Cut-off Voltage @load < 50% | 41.0Vdc | |
| Low DC Cut-off Voltage @load ≥ 50% | 40.0Vdc | |
| High DC Recovery Voltage | 62Vdc | |
| High DC Cut-off Voltage | 63Vdc | |
| No Load Power Consumption | 70W | 75W |
8.3 Two Load Output Power
| Inverter Model | 8.2KW | 10.2KW |
|---|---|---|
| Full Load | 8200W | 10200W |
| Maximum Main Load | 8200W | 10200W |
| Second Load Range | 1640W~5740W | 2040W~7140W |
| Main Load Cut Off Voltage | 52VDC | |
| Main Load Return Voltage | 54VDC | |
8.4 Charge Mode Specifications
| Inverter Model | 8.2KW | 10.2KW |
|---|---|---|
| Utility Charging Mode | ||
| Charging Algorithm | 3-Step | |
| AC Charging Current (Max) | 140Amp | 140Amp |
| Bulk Charging Voltage Flooded Battery | 58.4 | |
| Bulk Charging Voltage AGM / Gel Battery | 56.4 | |
| Floating Charging Voltage | 54Vdc | |
| MPPT Solar Charging Mode | ||
| Max. PV Array Power | PV1 Channel:5400W PV2 Channel:5400W | PV1 Channel:5400W PV2 Channel:5400W |
| IMax.PV | PV1 Channel:18A PV2 Channel:18A | PV1 Channel:18A PV2 Channel:18A |
| Nominal PV Voltage | 360Vdc | |
| PV Array MPPT Voltage Range | 90Vdc~450Vdc | |
| Max. PV Array Open Circuit Voltage | 500Vdc | |
| Max Charging Current (AC charger plus solar charger) | 160Amp | |
8.5 Grid-Tie Operation
| Inverter Model | 8.2KW | 10.2KW |
|---|---|---|
| Nominal Output Voltage | 220/230/240 VAC | |
| Feed-in Grid Voltage Range | 195~253VAC | |
| Feed-in Grid Frequency Range | 50±1Hz/60±1Hz | |
| Nominal Output Current | 35.6A | 44.3A |
| Power Factor Range | >0.99 | |
| Maximum Conversion Efficiency (DC/AC) | 98% | |
8.6 General Specifications
| Inverter Model | 8.2KW | 10.2KW |
|---|---|---|
| Safety Certification | CE | |
| Operating Temperature Range | -10°C to 50°C | |
| Storage temperature | -15°C~60°C | |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
| Dimension (D*W*H), mm | 500*390*136mm | |
| Net Weight, kg | 14.5 | 14.7 |
8.7 Approximate Back-up Time Table
| Model | Load (W) | Backup Time @ 48Vdc 100Ah (min) | Backup Time @ 48Vdc 200Ah (min) |
|---|---|---|---|
| 8.2KW/10.2KW | 500 | 613 | 1288 |
| 1000 | 268 | 613 | |
| 1500 | 158 | 402 | |
| 2000 | 111 | 271 | |
| 2500 | 90 | 215 | |
| 3200 | 76 | 182 | |
| 3500 | 65 | 141 | |
| 4000 | 50 | 112 | |
| 4500 | 44 | 100 | |
| 5000 | 40 | 90 | |
| 6200 | 36 | 80 | |
| 7200 | 32 | 70 | |
| 8200 | 28 | 60 | |
| 9200 | 24 | 50 | |
| 10200 | 20 | 40 |
Note:
- Backup time depends on the quality of the battery, age of battery, and type of battery. Specifications of batteries may vary depending on different manufacturers.
- The final interpretation right of this product belongs to the company.
9. User Tips
- PV Startup Voltage: For normal operation, the solar panel voltage must be above 120V if the inverter is used without an external battery. If an external battery is connected, 90V is sufficient for startup.
- BMS Communication: For optimal performance and safety, ensure both the inverter and your battery system have BMS (Battery Management System) functions to allow communication and automatic adjustment of charging parameters. The inverter supports PACE and PYLON BMS protocols.
- Cable Sizing: Always use the recommended cable cross-sections for battery, AC input/output, and PV connections to ensure system safety and efficient operation. Refer to the tables in the 'Setup' section for specific requirements.
- Parallel/Series Connection: This inverter model does not support parallel or series connection with other inverters.
- Wind Power: This is a solar hybrid inverter, primarily designed for solar power integration. While it can work with a generator or utility, its core functionality is optimized for solar energy.
10. Warranty and Support
The Daxtromn 10.2KW 48V Hybrid Solar Inverter comes with a 1-year warranty.
For detailed information, including comprehensive LCD settings and display icons, please refer to the full user manual available as a PDF document: Download User Manual (PDF).
If you encounter persistent errors after consulting the troubleshooting guide, please contact your local dealer or service center for maintenance.