1. Introduction
The GIRIER BHT-006 Series ZigBee Smart Thermostat is designed to control electric underfloor, water heating, or water/gas boiler systems. These units are suitable for use in commercial, industrial, civil, and domestic properties, offering advanced features such as APP remote control, voice control via Alexa/Google Home, and flexible 5+1+1 weekly programming for optimal comfort and energy efficiency.

2. Safety Information
Please read these instructions carefully before wiring and installing the thermostat. Failure to follow them could damage the product or cause a hazardous condition.
- Always ensure the power supply is OFF before installation or maintenance.
- Strictly follow the provided wiring diagram for installation.
- Installation should be performed by a trained, experienced service technician.
- Confirm that the fasteners are suitable for wall installation.
- Do not pull cables too hard to avoid damaging the product.
- If using hard plastic wire, bend it to an appropriate angle in advance.
- Do not attempt to repair the equipment yourself; contact after-sales service for failures.
- After installation, re-check the product operation to ensure normal and safe use. Keep this manual for future reference.
CAUTION: Electrical Shock or Equipment Damage Hazard. Disconnect power supply before installation.

3. Package Contents
Upon opening the box, you should find the following items:
- Thermostat (1 pc)
- Screws (2 pcs)
- User Manual (1 pc)
- Wall plate (1 pc)
- QC Passed Card (1 pc)
Note: Only the Electric Heating version (BHT-006GB) requires and includes an extra NTC sensor.

4. Specifications
| Feature | Specification |
|---|---|
| Brand Name | GIRIER |
| Model Number | ZigBee Thermostat (BHT-006 Series) |
| Certification | CE, RoHS |
| Origin | Mainland China |
| Rated Voltage | 95~240VAC, 50~60HZ |
| Current Load | 5A (Water/Gas Boiler/Water Heating); 16A (Electric Heating) |
| Sensor | NTC (Only electric heating needs it) |
| Temperature Accuracy | ±1℃ |
| Set Temp. Range | 5~35℃ |
| Room Temp. Range | 5~99℃ |
| Display Temp. Range | 5~99℃ |
| Ambient Temp. | 0~45℃ |
| Ambient Humidity | 5~95% RH (Non Condensing) |
| Storage Temp. | -10~45℃ |
| Power Consumption | <1.5W |
| Timing Error | <1% |
| Shell Material | PC+ABS (Fireproof) |
| Installation Box | 86*86mm Square or European 60mm Round Box |
| Wire Terminals | Wire 2*1.5mm2 or 1*2.5mm2 |
| Protection Class | IP20 |
| Buttons | Capacitive Touch Buttons |
| APP | TuyaSmart/Smart Life |
| Voice Control | Alexa/Google Home Assistant |
| Hub Requirement | Tuya ZigBee Hub |

5. Installation
5.1 Pre-installation Checks
Before proceeding with installation, ensure you have read and understood the safety information in Section 2. Verify that the product is suitable for your heating equipment and that the power supply is disconnected.
5.2 Wiring Diagram
Refer to the diagram below for correct wiring. Ensure all connections are secure and match your specific thermostat model (GA, GB, or GC).

GA is for water heating.
GB is for electric heating.
GC is for water/gas boiler.
NTC and Modbus are optional.
5.3 Mounting Instructions
Your thermostat is suitable for installation within a standard 86mm pattress box or European 60mm pattress box.
- Step 1: Keep power off.
- Step 2: Remove the mounting plate by pushing the LED assembly.
- Step 3: Connect power supply and load into the appropriate terminals as shown in the wiring diagram.
- Step 4: Fix the mounting plate into the wall box using screws.
- Step 5: Fix the thermostat body onto the mounting plate by aligning and pressing the lower button.
- Step 6: Installation complete.
6. Setup
6.1 APP Download and Account Registration
To utilize smart features, download the TuyaSmart or Smart Life APP:
- Search for "Smartlife" in the Apple App Store or Google Play Store.
- Alternatively, scan the QR code provided in the original user manual (not embedded here for security reasons).
- Complete account registration and installation following the in-app guidance.
6.2 Tuya ZigBee Hub Requirement
A Tuya ZigBee gateway (hub) is mandatory for APP pairing, remote control, and voice features. Without the hub, you can only operate the thermostat manually.

6.3 Connecting the Thermostat to the APP
Ensure your Tuya ZigBee wired or wireless gateway is connected and configured. Refer to your gateway's manual for its specific connection process.
Network Distribution Mode:
Method 1: ZigBee Quick Connect
- When the thermostat is off, press and hold the "down button" until the thermostat screen flashes quickly and displays the "zigbee" icon.
- Follow the instructions in the TuyaSmart/Smart Life APP to add the device.
Method 2: ZigBee Gateway Connection (Manual Pairing)
- With the thermostat turned off, press and hold the "down button" until the thermostat screen flashes quickly and displays the "zigbee" icon.
- In the TuyaSmart/Smart Life APP, navigate to add a new device and select the ZigBee Thermostat. Follow the on-screen prompts to complete the pairing process.
7. Operating Instructions
7.1 Home Screen Quick Reference
The thermostat features an intuitive LED display and capacitive touch buttons.

7.2 Basic Operations (During Power On)
- Power On/Off: Press the power button to turn the thermostat on or off.
- Function & Programmable Mode: Touch the mode button to switch between manual mode (displaying a hand icon) and programmable mode (displaying a calendar icon).
- Setting Temperature: In manual mode, press the up/down arrows to set the desired temperature. In programming mode, temperature settings are locked and must be adjusted via the program schedule or by switching to manual mode.
- Adjusting/Setting the Clock: Press the clock icon to set minutes, hours, and weekdays. Use the up/down arrows to adjust values and press the clock icon again to confirm and exit.
- Locking your Thermostat: In the advanced options (see 7.4), you can select full lock or half lock for the buttons.
7.3 Adjusting/Setting Program Schedules (Manual)
This method is used if there is no Wi-Fi connection between your thermostat and smartphone/tablet.

- Press the program icon four times in a row. You will see "MON TUE WED THU FRI" and the minutes of the time flashing.
- Use the up/down arrows to set the minutes.
- Press the program icon again, the hour will flash. Use the up/down arrows to set the hour.
- Press the program icon again, the temperature setting will flash. Use the up/down arrows to set the temperature. This completes the setting for Period 1.
- Repeat the process to complete settings for Periods 2, 3, 4, and 5 (displaying Periods 1,2 and then Periods 3,4).
- Press the program icon once more to enter the Saturday schedule settings (you will see "SAT" in the upper left corner). Repeat the above process for Saturday and Sunday schedules.
- Press the program icon once more to confirm and exit.
7.4 Setting Functions and Options (Advanced)
During Power Off, press and hold the power button and the down arrow button for 8 seconds to access system functions. Then press the mode button to scroll through available functions, and use the up/down arrows to change options. All settings are confirmed automatically.
| Code | Function | Default | Options/Description |
|---|---|---|---|
| 1 | Temperature compensation | -3 | -9 to 9 ℃ |
| 2 | Deadzone Temp. | 1 | 1-5℃ |
| 3 | Button Locking | 1 | 01: All buttons locked except power button. 02: All buttons locked. |
| 4 | Sensor type | AL | In: Internal Sensor (to control temp.) Ou: External Sensor (to control temp.) AL: Internal & External Sensor (Internal sensor to control temp., external sensor to limit temp.) |
| 5 | Min. Set Temp. | 5 | 5-15℃ |
| 6 | Max. Set Temp. | 35 | 15-45℃ |
| 7 | Temp. display | 00 | 00: Display set Temp. and Room Temp. 01: Only display set Temp. |
| 8 | Low temp. protection setting. | 0 | 0-10℃ |
| 9 | High temp. protection setting. | 30 | 30-70℃ |
| A | Daytime display brightness (6:00-22:00) | 1 | 0-8 (0: screen off after 10s inactivity) |
| B | Nighttime display brightness (22:00-06:00) | 1 | 0-8 (0: screen off after 10s inactivity) |
| C | Reset | 00 | 00: No factory reset; 01: Factory reset |
| D | Version number | U1 |
7.5 APP Remote Control
After pairing your ZigBee thermostat to TuyaSmart or Smart Life APP via a Tuya ZigBee hub, you can easily control the temperature of your heating system from anywhere.

7.6 Voice Control
The thermostat is compatible with Alexa and Google Home Assistant. Simply give voice commands to control your smart ZigBee thermostat hands-free.

7.7 Share & Group Control
Share APP access with family members so everyone can adjust temperatures to their comfort. You can also group multiple thermostats (e.g., living room, bedrooms) for centralized whole-home control or personalized zone temperatures.

8. Maintenance
The GIRIER BHT-006 Series ZigBee Smart Thermostat requires minimal maintenance. Keep the display clean with a soft, dry cloth. Do not use abrasive cleaners or solvents. For any malfunctions or issues, do not attempt to repair the device yourself. Contact customer support or a qualified technician.
9. Troubleshooting
| Phenomenon | Handling |
|---|---|
| Power is on but without display. | Check if the terminals between the LCD panel and Power Unit Box are loose. Use a new LCD panel or new Power Unit Box to replace the old one. |
| Without output but display works. | Check wiring connections to the heating system. Ensure the current load matches the thermostat's specifications. |
| Room Temp. is a little different from the actual. | Perform temperature calibration in item 1 of the high senior options (see Section 7.4). |
10. User Tips
- Temperature Accuracy: The thermostat has a temperature accuracy of ±1℃. If you notice a discrepancy, use the temperature compensation setting (Code 1 in advanced options) to fine-tune it.
- Electric Heating Sensor: Remember that only the Electric Heating version (BHT-006GB) requires and includes an external NTC sensor for accurate floor temperature measurement.
- Manual Protection Settings: Low and high temperature protection settings can only be adjusted manually through the thermostat's advanced options (Codes 8 and 9).
- Deadzone Temperature: The thermostat will only activate heating when the difference between the current room temperature and the target temperature reaches the set deadzone temperature value. This prevents frequent on/off cycling.
- Power-Off Memory: The thermostat retains all customized settings during power outages, so no need to reconfigure after power returns.
11. Warranty and Support
This product comes with a 24-month warranty from the date of purchase. Service beyond the warranty period may incur charges. For more details or technical support, please contact your retailer or the manufacturer's customer service.
For a comprehensive guide and detailed diagrams, please refer to the full User Manual PDF: GIRIER BHT-006 Series Thermostat User Manual (PDF)