1. Product Overview

The LiTime 24V 3000W Pure Sine Wave Solar Inverter Charger is an all-in-one solution designed to provide a comprehensive energy management system for various applications. It integrates an inverter, a solar charge controller (MPPT), and a battery charger into a single unit, ensuring efficient power conversion and reliable operation for your solar energy system.

LiTime 24V 3000W Solar Inverter Charger front view with display and control buttons.
Front view of the LiTime 24V 3000W Solar Inverter Charger, showing the LCD display, control buttons (SET, UP/DECREASE, DOWN/INCREASE, EXIT), and status indicators (FAULT, CHARGE, OUTPUT). Key specifications like 24VDC, 110-120VAC, 60Hz, Max. PV Input 150V/1600W, Max. Charge Current (MPPT) 60A, AC Input Voltage 110V, Max. Charge Current (AC Charger) 50A are visible.

Key Features:

  • Integrated MPPT Pure Sine Wave Inverter, Solar Charge Controller, and Battery Charger.
  • LCD+LED Display for real-time information.
  • Comprehensive protection features for enhanced safety and longevity.
  • Compatible with Lithium and Lead Acid battery types, with user-configurable settings.

Applications:

This versatile inverter charger is suitable for a wide range of applications, including:

LiTime 24V 3000W Solar Inverter Charger widely used applications.
Examples of where the inverter charger can be widely used: Home UPS, Farm, Garage, Solar System.
  • Home UPS (Uninterruptible Power Supply)
  • Farm power systems
  • Garage power solutions
  • General solar energy systems

2. Safety Information

Please read all instructions and warnings carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Ensure all wiring is performed by qualified personnel.
  • Do not disassemble the unit. There are no user-serviceable parts inside.
  • Keep the unit away from water, moisture, and flammable materials.
  • Ensure adequate ventilation around the unit to prevent overheating.
  • Always disconnect power before performing any maintenance or wiring.

3. Installation and Setup

3.1 Unpacking and Inspection

Upon receiving the inverter charger, carefully unpack it and inspect for any shipping damage. If any damage is found, contact your supplier immediately.

3.2 Mounting the Unit

Mount the inverter charger in a clean, dry, and well-ventilated area. Ensure there is sufficient clearance around the unit for proper airflow. The unit dimensions are:

  • Height: 18.31 inches (46.5 cm)
  • Length: 12.20 inches (30.99 cm)
  • Width: 5.31 inches (13.49 cm)
LiTime 24V 3000W Solar Inverter Charger dimensions.
Diagram illustrating the dimensions of the All-in-One Solar Inverter Charger: Height (H) 18.31 inches, Length (L) 12.20 inches, Width (W) 5.31 inches.

3.3 Wiring Connections

Refer to the diagram below for proper wiring connections. Ensure all connections are secure and correctly polarized.

LiTime 24V 3000W Solar Inverter Charger rear panel connections.
Detailed diagram of the rear panel connections:
  1. On/Off Switch: Main power switch for the unit.
  2. AC Input Breaker (40A): Circuit breaker for AC input protection.
  3. AC Input Terminal Block: Connect utility grid or generator AC input here.
  4. AC Output Terminal Block: Connect your AC loads here. Continuous Output Power: 3000W, 110-120VAC, 60Hz.
  5. PV Input Terminals: Connect solar panel array (PV) input here. Max. PV Input: 150V | 1600W.
  6. Battery Terminals: Connect your 24V battery bank here.
  7. DC Fuse Panel (Replaceable Fuse): Contains a replaceable DC fuse for protection.
  8. Cooling Fans: Ensure these are not obstructed for proper heat dissipation.

Important Wiring Note: The Utility power (Grid) and generator AC cannot be used simultaneously. Ensure only one AC source is connected at a time to the AC Input Terminal Block.

LiTime 24V 3000W Solar Inverter Charger system wiring diagram.
Illustrative wiring diagram showing the inverter charger connected to Solar panels, a Battery System, a Load, a Generator, and the Grid. Note: The Utility power (Grid) and generator AC cannot be used simultaneously.

4. Operation

4.1 Initial Power-Up

  1. Ensure all wiring connections are correct and secure.
  2. Turn on the battery bank's main disconnect switch (if applicable).
  3. Flip the On/Off Switch (1) on the inverter charger to the 'ON' position.
  4. The LCD display will light up, showing system status.

4.2 LCD Display and Control Buttons

The LCD display provides real-time information about the system's operation. Use the control buttons to navigate menus and adjust settings:

  • SET: Enter menu or confirm selection.
  • UP/DECREASE: Navigate up or decrease value.
  • DOWN/INCREASE: Navigate down or increase value.
  • EXIT: Exit menu or return to previous screen.

4.3 Battery Type Configuration

This inverter charger supports Lithium, Lead Acid, and user-defined battery types. It is crucial to configure the correct battery type and charging parameters for optimal performance and battery longevity. Refer to the detailed settings menu in the full manual for specific adjustments.

4.4 System Operation Modes

The inverter charger can operate in various modes, typically including:

  • Inverter Mode: Converts DC power from batteries to AC power for loads.
  • Charger Mode: Charges batteries from solar panels (MPPT) or AC utility/generator.
  • UPS Mode: Provides uninterrupted power to loads by switching between utility and battery power.

Consult the full manual for detailed instructions on selecting and configuring operation modes.

5. Protection Features

The LiTime inverter charger is equipped with multiple protection mechanisms to ensure safe and reliable operation of your solar energy system:

LiTime 24V 3000W Solar Inverter Charger protection features.
Visual representation of the comprehensive protection features.
  • Night PV Prevents Backcharging: Prevents current flow from battery to solar panels at night.
  • Battery Low-Voltage Protection: Shuts down output to protect batteries from over-discharge.
  • Battery Overvoltage Protection: Prevents batteries from being overcharged.
  • Battery Reverse Protection: Protects against incorrect battery polarity connection.
  • PV Reverse Protection: Protects against incorrect solar panel polarity connection.
  • Charging Short Circuit Protection: Protects the charging circuit from short circuits.
  • Over Temperature Protection: Shuts down the unit if internal temperature exceeds safe limits.
  • Overload Protection: Protects the inverter from excessive load.
  • Load Output Short Circuit Protection: Protects the AC output from short circuits.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter charger.

  • Cleaning: Periodically clean the exterior of the unit with a dry cloth. Ensure cooling fan vents are free from dust and debris.
  • Connection Checks: Annually inspect all wiring connections (battery, solar, AC input/output) for tightness and signs of corrosion. Tighten any loose connections.
  • Ventilation: Ensure the installation area remains well-ventilated and free from obstructions to the cooling fans.
  • Fuse Inspection: Check the DC Fuse Panel (7) periodically. If a fuse blows, replace it with one of the same type and rating.

7. Troubleshooting

This section provides solutions to common issues. For problems not listed here, contact technical support.

Problem Possible Cause Solution
No power output from inverter.
  • Inverter is OFF.
  • Low battery voltage.
  • Overload condition.
  • Blown DC fuse.
  • Turn the On/Off switch to ON.
  • Charge batteries or check battery connections.
  • Reduce load connected to the inverter.
  • Check and replace DC fuse if necessary.
"FAULT" indicator is ON.
  • Overload.
  • Over temperature.
  • Short circuit at output.
  • Battery fault (over/under voltage, reverse polarity).
  • Check LCD for specific error code.
  • Reduce load.
  • Ensure proper ventilation.
  • Check output wiring for shorts.
  • Verify battery connections and voltage.
Batteries not charging from solar.
  • PV input voltage too low/high.
  • PV reverse polarity.
  • Shading on solar panels.
  • Check PV voltage against specifications (Max. PV Input 150V).
  • Verify PV wiring polarity.
  • Clear any shading on solar panels.

8. Specifications

Parameter Value
Product NameLiTime 24V 3000W Pure Sine Wave Solar Inverter Charger
Model NumberHYBINV-24V3KW-T
Inverter TypeMPPT Pure Sine Wave Inverter
Input Voltage110V to 120V
Output Voltage110V to 120V
Output Current110A
Output Frequency60Hz±5%
Output TypeDual
Size (L*W*H)18.31*12.20*5.31 inches (46.5 x 30.99 x 13.49 cm)
Inverter Efficiency3000W
Weight41.73 lbs (18.93 kg)
Max. PV Input150V | 1600W
Max. Charge Current (MPPT)60A
Max. Charge Current (AC Charger)50A
AC Input Voltage (Charger)110V
DisplayLCD+LED Display
Battery Type CompatibilityLithium, Lead Acid, User-defined
Operating Temperature Range32°F to 104°F / 0°C to 40°C
Storage Temperature14°F to 122°F / -10°C to 50°C
OriginMainland China, Guangdong

9. User Tips

  • Ventilation is Key: Always ensure the inverter charger has ample space for airflow, especially around the cooling fans. Overheating can reduce efficiency and lifespan.
  • Monitor the Display: The LCD display provides critical real-time data. Regularly check it for system status, battery levels, and any fault indicators to catch potential issues early.
  • Battery Settings: If using a custom battery type (e.g., specific lithium chemistries), take the time to accurately configure the charging parameters (voltage limits, current) in the settings menu to maximize battery health and performance.
  • Load Management: Be mindful of the total load connected to the inverter. Avoid exceeding the 3000W continuous output power to prevent overload shutdowns.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. Ensure you have your model number (HYBINV-24V3KW-T) and purchase details available when contacting support.

Manufacturer Contact: For quick assistance, you may contact the seller via WhatsApp: +86 17680717689 or Email: maoyishunda@gmail.com.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.