1. Introduction
The Mudiro M-5S Evo-H is an advanced 8KW diesel air heater designed for versatile heating applications in various environments, including camping, RVs, tents, trucks, boats, cabins, and garages. This all-in-one unit features intelligent controls, robust safety mechanisms, and efficient heating performance. This manual provides essential information for the safe and effective operation and maintenance of your heater.
2. Key Features
- Advanced CO Safety System: Built-in carbon monoxide sensor with auto shut-off and customizable alarm.
- Automatic Altitude Compensation: Real-time auto-adjustment for optimal performance up to 18,045 ft (5,500 m).
- Precise Temperature Control: Wireless temperature sensor with ±2°F (1-2°C) precision and smart auto start/stop.
- Multi-Voltage Support: Compatible with 12V, 24V, and 240V power sources (AC adapter included).
- Triple Control System: Operate via TFT LCD panel, 98 ft remote control, or 98 ft Bluetooth app.
- Ultra-Quiet Operation: Upgraded noise-reducing fuel pump, operating at 50-55dB.
- High Heating Efficiency: 8KW power, heating areas up to 289 ft² (27 m²) with low fuel consumption (0.12–0.36L/h).
- Timer Function: Set up to 3 groups for scheduled operation.
- Durable Design: Features a retractable PVC handle, leak-proof fuel cap, and sturdy POM base.
3. Safety Information
Always read and understand all safety warnings and instructions before installing or operating this heater. Failure to follow these instructions may result in fire, explosion, electric shock, or serious injury.
3.1 Carbon Monoxide (CO) Protection
This heater is equipped with an advanced CO safety system. A built-in carbon monoxide sensor continuously monitors CO levels. If unsafe levels are detected, the unit will trigger an alarm and automatically shut down to prevent CO poisoning.
- Dangerous CO: > 50 PPM
- High Danger: > 150 PPM
- Lethal: > 400 PPM
You can customize the alarm response time and CO alarm threshold (PPM) via the control panel or app.
3.2 General Safety Precautions
- Ensure adequate ventilation when operating the heater.
- Do not block the air intake or exhaust outlets.
- Keep flammable materials at a safe distance from the heater.
- Do not operate the heater in enclosed, unventilated spaces without proper exhaust routing.
- Regularly inspect the exhaust system for leaks or damage.
- Ensure the fuel cap is leak-proof and securely fastened to prevent spills and odors.
- Use only diesel fuel as specified.
- Do not touch hot surfaces during or immediately after operation.
- Keep children and pets away from the operating heater.
4. Packing List
Before setup, verify that all components are present in the package:
- 1x Mudiro M-5S Evo-H Diesel Heater
- 1x Remote Control
- 1x TFT Switch (LCD Control Panel)
- 1x AC Adapter (for 240V operation)
- 1x Intake Pipe
- 1x Exhaust Pipe (90mm wide)
- 1x Air Outlet Pipe
- 1x Muffler
- 1x Air Filter
- 1x Diesel Strainer
- 1x Set of Installation Parts
- 1x User Manual
- 1x TFT Switch Extension Cord
- 3x Direct Links (for multi-zone heating)
5. Setup and Installation
The Mudiro M-5S Evo-H is an all-in-one unit designed for ease of use. Follow these general steps for setup. Refer to the included User Manual for detailed installation instructions and diagrams specific to your application (e.g., vehicle, tent, cabin).
5.1 Placement
- Place the heater on a stable, level, and non-flammable surface.
- Ensure sufficient clearance around the heater for proper airflow and heat dissipation.
- Consider the routing of the intake and exhaust pipes to ensure safe operation and prevent exhaust fumes from entering the heated space.
5.2 Fueling
- Fill the integrated 3.5L fuel tank with clean diesel fuel.
- Ensure the leak-proof fuel cap is securely fastened after fueling.
- Install the provided diesel strainer to ensure clean fuel flow and extend system life.
5.3 Exhaust and Intake Connection
- Connect the intake pipe to the designated intake port on the heater.
- Connect the 90mm wide exhaust pipe to the exhaust port.
- Route the exhaust pipe safely outside the heated area, ensuring no fumes can re-enter. Use the muffler to reduce noise.
- If using multi-zone heating, connect the three direct links to distribute warm air.
5.4 Power Connection
The heater supports multiple power inputs:
- 12V/24V DC: Connect directly to a compatible 12V or 24V DC power source using the DC Power Terminals.
- 240V AC: Use the included AC adapter to plug the heater into a standard household outlet via the Grounded Outlet.
5.5 Control Panel Connection
Connect the TFT Switch (LCD Control Panel) to the heater. An extension cord is provided for flexible placement of the control panel.
6. Operation
The Mudiro M-5S Evo-H offers multiple control options for convenience.
6.1 TFT LCD Control Panel
The TFT LCD Switch provides comprehensive control and real-time information. Refer to the diagram below for button functions and display indicators.
| No. | Function |
|---|---|
| 1 | Power Button |
| 2 | Confirm Button |
| 3 | Adjust Up Button |
| 4 | Adjust Down Button |
| 5 | Remote Control Pairing Status Indicator |
| 6 | Bluetooth Connection Status Indicator |
| 7 | Auto Start/Stop Function Indicator |
| 8 | Voice Broadcast Indicator |
| 9 | Power Supply Voltage Display |
| 10 | Real-time Altitude Display |
| 11 | CO Alarm Time and CO Level Display |
| 12 | CO Alarm On/Off |
| 13 | Language Indicator |
| 14 | 10 Gear Temperature Setting |
| 15 | Temperature Control Mode Display |
| 16 | Case Temperature or Set Temperature Display |
| 17 | Temperature Unit |
6.2 Remote Control
The included remote control allows you to operate the heater from up to 98 feet away. It comes pre-paired for immediate use. Functions typically include power on/off, temperature adjustment, and mode selection.
6.3 Bluetooth App Control
Download the dedicated Mudiro app to control your heater via Bluetooth from up to 98 feet. The app provides advanced features such as:
- Power on/off
- Temperature adjustment (46.4°F-96.8°F / 8°C-36°C)
- Setting up to 3 timer groups
- Monitoring real-time altitude and CO levels
- Customizing CO alarm settings
- Accessing additional settings and diagnostics
Scan the QR code in the included User Manual to download the app.
6.4 Key Features in Operation
- Automatic Altitude Compensation: The heater features a real-time altitude sensor and automatically adjusts the air-fuel mix for optimal efficiency up to 18,045 ft (5,500 m).
- Precise Temperature Control: The wireless temperature sensor ensures precise temperature control with a fluctuation range of ±2°F (1-2°C). The heater will auto start/stop to maintain the set temperature.
- Timer Function: Set up to 3 different timer groups for automatic power on/off.
- Quiet Operation: The upgraded noise-reducing fuel pump ensures a quiet operation, typically between 50-55dB.
- Overheat Protection: The system includes overheat protection to ensure safe operation.
7. Maintenance
Regular maintenance ensures the longevity and efficient operation of your Mudiro diesel heater.
- Cleanliness: Keep the exterior of the heater clean and free from dust and debris.
- Air Filter: Periodically check and clean or replace the air filter to ensure proper airflow.
- Diesel Strainer: Inspect the diesel strainer regularly and clean it to prevent blockages and ensure clean fuel delivery.
- Exhaust System: Check the exhaust pipe and muffler for any signs of damage, corrosion, or blockages. Ensure all connections are secure.
- Fuel Tank: Drain and clean the fuel tank periodically, especially before long periods of storage, to prevent fuel degradation and sediment buildup.
For detailed maintenance schedules and procedures, refer to the comprehensive User Manual provided with your product.
8. Troubleshooting
If you encounter issues with your Mudiro M-5S Evo-H diesel heater, consider the following basic troubleshooting steps. For more complex problems, consult the detailed troubleshooting guide in your User Manual or contact customer support.
- Heater Not Starting:
- Check power connection and ensure adequate voltage (12V/24V/240V).
- Verify fuel level in the tank.
- Ensure the fuel strainer is not clogged.
- Check for any error codes on the TFT display.
- Insufficient Heat Output:
- Ensure air intake and exhaust are not obstructed.
- Check the set temperature on the control panel or app.
- Verify the air filter is clean.
- CO Alarm Triggered:
- Immediately ventilate the area.
- Check exhaust pipe for leaks or blockages.
- Ensure proper outdoor routing of exhaust.
- If the alarm persists, cease operation and investigate the cause.
- Unusual Noise:
- Check for loose components or obstructions in the fan.
- Ensure the heater is on a stable surface.
9. Specifications
| Feature | Detail |
|---|---|
| Brand | Mudiro |
| Model | M-5S Evo-H |
| Power | 8KW |
| Applicable Voltage | 12V/24V/240V |
| AC Adapter | Equipped |
| Fuel Tank Capacity | 3.5L |
| Fuel Consumption | 0.12-0.36L/h |
| Color | Orange |
| Applicable Area | 215-289 ft² / 20-27 m² |
| Adjustable Temperature Range | 46.4°F-96.8°F / 8°C-36°C |
| Operating Temperature Range | -40°F-104°F / -40°C-40°C |
| Control Methods | TFT Panel, Remote Control (98ft), Bluetooth App Control (98ft) |
| Altitude Adaptive | Altitude sensor, real-time display, automatic adjustment |
| Maximum Altitude | 5500m / 18045 ft |
| Timer | Support, 3 groups can be set |
| CO Protection | Support, Custom Alarm Response Time & CO Alarm Threshold (PPM), Auto Shut-off |
| Wireless Temperature Sensor | Auto Start/Stop with ±2°F precision |
| Voice Broadcast | Support |
| Overheat Protection | Support |
| Thermostat | Yes |
| Silencer | Yes |
| Quiet Fuel Pump | Yes |
| Noise Level | 50-55dB |
| Item Weight | 11 kg |
| Item Height | 27 cm |
| Item Width | 25 cm |
| Item Length | 38 cm |
| External Testing Certification | CE |
| Certification | RoHS, CE |
| Origin | Mainland China |
10. User Tips
- For optimal heating in larger spaces or multiple zones, utilize the three direct links provided to distribute warm air effectively.
- When operating in extremely cold conditions (-40°F), ensure the heater is placed on a stable, insulated surface to maximize efficiency.
- To maintain quiet operation, regularly check and clean the air filter and diesel strainer.
- Familiarize yourself with the Bluetooth app for advanced control and monitoring, especially for setting timers and customizing CO protection.
11. Warranty and Support