1. Introduction
This manual provides essential information for the safe and efficient operation of your SWIPOWER 4000VA 3600W Hybrid Solar Inverter. It covers installation, operation modes, maintenance, and troubleshooting. Please read this manual thoroughly before installation and use to ensure proper functionality and longevity of the product.
2. Safety Information
Always observe the following safety precautions during installation, operation, and maintenance:
- All electrical installations must comply with local and national electrical codes.
- Installation should only be performed by qualified personnel.
- Ensure proper grounding of the inverter.
- Do not expose the inverter to rain, snow, spray, or any liquids.
- Ensure adequate ventilation around the inverter to prevent overheating.
- Do not disassemble the inverter. There are no user-serviceable parts inside.
- Wear appropriate personal protective equipment (PPE) during installation.
3. Package Contents
Verify that all items are present in the package:
- SWIPOWER 4000VA 3600W Hybrid Solar Inverter
- User Manual (this document)
- (Any additional accessories like mounting hardware or communication cables may be included depending on the specific package.)
4. Product Overview
The SWIPOWER Hybrid Solar Inverter is a versatile power solution designed for both on-grid and off-grid applications. Key features include:
- High-Efficiency MPPT Charger: Integrated 120A MPPT solar charge controller for maximum power point tracking from PV arrays.
- Flexible Operation: Supports on-grid, off-grid, and hybrid modes.
- Pure Sine Wave Output: Provides clean and stable AC power suitable for sensitive electronics.
- Battery-Independent Operation: Capable of running loads directly from solar power without a battery.
- Durable Design: Features a built-in anti-dust kit for enhanced reliability in harsh environments.
- User-Programmable: Customizable settings for various 24V battery types.
- Intuitive Interface: Equipped with an LCD display and RGB light effects for easy monitoring and status indication.



5. Setup
5.1 Physical Installation
The inverter should be mounted in a well-ventilated area, away from direct sunlight, heat sources, and flammable materials. Ensure the mounting surface is sturdy enough to support the inverter's weight. The inverter dimensions are approximately 44 cm (17.32 in) in height, 36 cm (14.17 in) in width, and 11 cm (4.33 in) in depth.

5.2 Wiring Connections
Refer to the wiring diagram below for proper connection of PV panels, batteries, AC input, and AC output. All wiring should be done by a qualified electrician following all applicable codes.

- PV Input (Solar Panels):
- PV Power: 4200W
- Max. PV Open Circuit Voltage: 500VDC
- PV MPPT Voltage Range: 60-500VDC
- Start-up voltage (initial charging): >90VDC
- Suggested cable: 12AWG
- It is recommended to connect solar panels in series.
- Battery Connection:
- Battery Type: Lead-Acid (Seal, AGM, Gel, Flooded) and Lithium battery
- Battery Voltage: 24V
- Wire Size: 2AWG
- Cable: 25mm²
- AC Input (Mains/Generator):
- Max AC Input Voltage: 120VAC
- Charging Current: 100A
- Suggested cable: 12AWG
- Recommended breaker: 32A
- AC Output (Main Out):
- AC Output Power: 3600W
- AC Output Voltage: 110/120Vac
- Peak power: 7200W
- Suggested cable: 12AWG
- Recommended breaker: 32A
- AC Output (Second Out):
- AC Output Power: 1200W
- The main output port will stop working when the battery voltage falls below the set range.
- Only the second output port can work within the setting range of 20V-23V.
5.3 Initial Configuration
After all connections are secure, power on the inverter. The unit features a 'One-key restoration to factory settings' option for easy setup. For Lithium batteries, there is a 'Built-in Lithium battery automatic activation' function.
6. Operating Modes
The inverter offers flexible charging and output modes to suit various energy management needs.

6.1 Charging Modes
- Solar First: Prioritizes solar power for charging the battery.
- Solar and Utility (Same Time): Utilizes both solar and utility power simultaneously for battery charging.
- Only Solar: Charges the battery exclusively from solar power.
6.2 Output Modes
- Solar First: Prioritizes solar power to supply connected loads. Utility power and battery serve as backup.
- Utility First: Prioritizes utility power to supply connected loads. Solar power and battery serve as backup.
- SBU Priority (Solar-Battery-Utility): Prioritizes solar power, then battery power, and finally utility power for connected loads.
7. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your inverter.
- Inspection: Periodically check all wiring connections for tightness, signs of wear, or corrosion.
- Cleaning: Keep the inverter's ventilation openings clear of dust and debris. The unit has a built-in anti-dust kit, but regular cleaning is still recommended. Use a dry, soft cloth for cleaning the exterior. Do not use liquid cleaners or solvents.
- Environment: Ensure the operating environment remains within the specified temperature and humidity ranges.
- Battery Health: Monitor battery health and ensure proper charging cycles according to your battery type. The smart battery charge design helps optimize battery life.
8. Troubleshooting
If you encounter issues with your inverter, refer to the following common problems and solutions:
- No Power Output:
- Check all battery connections for proper polarity and tightness.
- Verify that the AC input (utility or generator) is active and connected correctly.
- Ensure PV panels are receiving sufficient sunlight and are connected to the inverter.
- Check all circuit breakers and fuses for trips or blown conditions.
- Battery Not Charging:
- Confirm PV panels are connected and producing power.
- If using utility charging, ensure AC input is present and within acceptable voltage range.
- Check battery settings on the inverter's display.
- Inverter Overload:
- Reduce the total load connected to the inverter.
- Check for any short circuits in the connected appliances.
- The inverter may automatically shut down to protect itself from overload.
- Error Codes on LCD:
- Note down the specific error code displayed on the LCD.
- Consult the full product manual (if available) or contact technical support with the error code for detailed solutions.
9. Specifications
Technical specifications for the SWIPOWER 4000VA 3600W Hybrid Solar Inverter (Model: ECO-3.6KW):
| Category | Parameter | Value |
|---|---|---|
| General | Model | ECO-3.6KW |
| Phase | 1-phase | |
| Maximum PV Input Power | 4200W | |
| Rated Output Power | 3600W/3600VA (3000/3150/3300) | |
| Maximum Solar Charging Current | 120A | |
| Grid-Tie Operation (PV Input DC) | Nominal DC Voltage/Maximum DC Voltage | 360/500VDC |
| Start-up Voltage/Initial Feeding Voltage | 60VDC/90VDC | |
| MPPT Voltage Range | 60~450VDC | |
| Maximum Input Current | 1/18A | |
| Grid-Tie Operation (Grid Output AC) | Nominal Output Voltage | 120VAC (100/105/115V settable) |
| Output Voltage Range | 90-150VDC | |
| Nominal Output Current | 30A | |
| Power Factor | >0.99 | |
| Efficiency | Maximum Conversion Efficiency (DC/AC) | 98% |
| Two Load Output Power | Full Load | 3600W |
| Maximum Main Load | 3600W | |
| Maximum Second Load (battery mode) | 1200W | |
| Maximum Load Cut Off Voltage | 26VDC | |
| Maximum Load Return Voltage | 27VDC | |
| Off-Grid Operation (AC Input) | AC Start-up Voltage/Auto Restart Voltage | 110VAC/120VAC |
| Acceptable Input Voltage Range | 90~145VAC ±2% | |
| Frequency Range | 49~51 ±1HZ | |
| Maximum AC Input Current | 40A | |
| Off-Grid Operation (PV Input DC) | Nominal DC Voltage/Maximum DC Voltage | 360/500VDC |
| MPPT Voltage Range | 60-450VDC | |
| Maximum Input Current | 1/18A | |
| Off-Grid Operation (Battery Mode Output AC) | Nominal Output Voltage | 120VAC (100/105/115V settable) |
| Output Waveform | Pure sine wave | |
| Efficiency (DC to AC) | 94% | |
| Battery & Charger | Nominal DC Voltage | 24VDC |
| Maximum Solar Charging Current | 120A | |
| Maximum AC Charging Current | 100A | |
| Maximum Solar+AC Charging Current | 120A | |
| Hybrid Operation (PV Input DC) | Nominal DC Voltage/Maximum DC Voltage | 360/500VDC |
| Start-up Voltage/Initial Feeding Voltage | 90VDC/120VDC | |
| MPPT Voltage Range | 60~450VDC | |
| Maximum Input Current | 1/18A | |
| Hybrid Operation (Grid Output AC) | Nominal Output Voltage | 120VAC (100/105/115V settable) |
| Output Voltage Range | 60-450VDC | |
| Nominal Output Current | 30A | |
| Hybrid Operation (AC Input) | AC Start-up Voltage /Auto Restart Voltage | 120-140VAC/180VAC |
| Acceptable Input Voltage Range | 90-280VAC or 170-280VAC | |
| Maximum AC Input Current | 40A | |
| Maximum Charging Current | 120A |
10. User Tips
No specific user tips from customer reviews or Q&A were available at the time of writing this manual. Always ensure proper ventilation and follow the wiring instructions carefully for optimal performance.
11. Warranty and Support
For warranty information, technical assistance, or any product-related inquiries, please contact your vendor or the manufacturer directly. It is recommended to keep your purchase receipt and the product's model number (SRC-4000VA-US) handy when seeking support.