1. Product Overview
The DATOUBOSS 15.36kWh LiFePO4 Battery (Model LFP48-300-FSD) is a high-capacity, long-cycle-life energy storage solution designed for various applications, including residential, RV/camping power systems, emergency backup, and more. It features a 51.2V nominal voltage, 300Ah single battery capacity, and supports communication protocols like RS232, RS485, and CAN. The unit is equipped with a touch screen for real-time data display and easy configuration.

Figure 1: Front view of the DATOUBOSS 15.36kWh LiFePO4 Battery.
Video 1: Product overview showcasing features like wall-mount capability, connections, and touch screen display.
2. Safety Information
Always follow basic safety precautions when installing, operating, or maintaining the battery. Failure to do so may result in electric shock, fire, or serious injury. Keep children and pets away from the battery unit. Do not attempt to open or modify the battery pack.
- Ensure proper ventilation around the battery.
- Do not expose the battery to water, fire, or extreme temperatures.
- Use appropriate personal protective equipment (PPE) during installation and maintenance.
- Consult a qualified electrician for installation if you are unsure.
3. Setup and Installation
3.1 Unpacking and Inspection
Before installation, carefully inspect the unit for any damage that may have occurred during transit. Ensure all items listed below are present in the package.

Figure 2: Installation instructions and list of package contents.
Package Contents:
- Mounting Bracket x1
- Screws x3
- Finished home energy storage battery pack x1
- Wall-Mount Brackets x2
- Positive Battery Connection Cable x1
- Negative Battery Connection Cable x1
- Communication cable x1
- Screws x8
- Instruction manual x1
3.2 Physical Dimensions and Mounting
The battery unit measures approximately 86cm (33.8in) in height, 45cm (17.7in) in width, and 26cm (10.2in) in depth. It can be wall-mounted, requiring a clearance of 50cm (19.6in) from both the top and bottom for proper installation and ventilation.

Figure 3: Physical dimensions and wall-mount considerations.
3.3 Connections and Interfaces
The rear panel of the battery unit provides various connection points and interfaces for power and communication.

Figure 4: Rear panel connections and side switches.
Interface Definitions:
| Interface | Functional Description | PIN | Description |
|---|---|---|---|
| RS485 (Inverter Interface) | Connection to host computer or inverter | 1, 8 | RS485-B1 |
| 2, 7 | RS485-A1 | ||
| CAN | Connection to host computer or inverter | 1, 6 | CANH1 |
| 2, 7 | CANL1 | ||
| RS232 (Upper Computer Interface) | Parallel communication | 3 | TX |
| 4 | RX | ||
| 5 | GND | ||
| RS485 (ADD-IN) | Parallel communication | 1, 8 | RS485-B2 |
| 2, 7 | RS485-A2 | ||
| RS485 (ADD-OUT) | Parallel communication | 1, 8 | RS485-B3 |
| 2, 7 | RS485-A3 |
Figure 5: Interface Definition table for communication ports.
Parallel Wiring Instructions:
For parallel operation of multiple battery packs, configure the DIP switches (ADS) on the rear panel according to the desired address. The unit supports up to 15 parallel units.

Figure 6: Example of parallel dialing method and automatic address assignment parallelization.
Example of Parallel Dialing Method:
- PACK1: Dial 1/6 ON
- PACK2: Dial 2/6 ON
- PACK3: Dial 3/6 ON
- ...and so on...
- PACK13: Dial 1/3/4/6 ON
- PACK14: Dial 2/3/4/6 ON
Example of Automatic Address Assignment Parallelization:
Set all DIP switches (1-6) to ON for automatic assignment in wiring order.
4. Operating Instructions
4.1 Powering On/Off
- To power on the unit, ensure all connections are secure, then switch the "Air Switch" to the ON position.
- Press the "Push button Switch" to activate the system.
- The "RUN" indicator on the rear panel should illuminate.
- To power off, reverse the process: press the "Push button Switch" to deactivate, then switch the "Air Switch" to OFF.
4.2 LCD Touch Screen Display
The integrated LCD touch screen provides real-time monitoring and control of the battery system.

Figure 7: LCD Touch Screen interface.
Key Displayed Information:
- Voltage/V: Current battery voltage.
- Capacity: Remaining battery capacity (Ah).
- Current/A: Current flowing in/out of the battery.
- Power: Instantaneous power output/input (W).
- CHG (Charge) / DSG (Discharge): Indicates charging or discharging status.
- State: Overall system status.
- MIN/MAX mV: Minimum and maximum cell voltages.
- MIN/MAX °C: Minimum and maximum battery temperatures.
Navigation Buttons:
- master: View master unit information.
- slave: View slave unit information (in parallel configurations).
- parameter: Access system parameters for configuration.
- protocol: View communication protocol settings.
- setting: General system settings.
5. Maintenance
Regular maintenance ensures optimal performance and longevity of your DATOUBOSS LiFePO4 Battery.
- Cleaning: Keep the battery unit clean and free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners.
- Connections: Periodically check all power and communication cable connections to ensure they are secure and free from corrosion.
- Ventilation: Ensure that the ventilation areas are not obstructed to prevent overheating.
- Monitoring: Regularly monitor the battery's performance via the LCD touch screen or connected monitoring system. Pay attention to any unusual readings or alarm indicators.
- Firmware Updates: Check the manufacturer's website for any available firmware updates to ensure your battery operates with the latest features and improvements.
6. Troubleshooting
This section provides basic troubleshooting steps for common issues. For more complex problems, contact customer support.
6.1 Common Issues and Solutions
- Battery not powering on:
- Check if the "Air Switch" is in the ON position.
- Ensure the "Push button Switch" has been pressed.
- Verify all power cables are securely connected.
- Check the main contact connections.
- No display on LCD screen:
- Ensure the battery is powered on.
- Check for any loose internal connections (if safe to access and within warranty terms).
- Alarm indicator (ALM) is lit:
- Refer to the specific alarm codes (if available in the full manual) or contact customer support with the displayed error message.
- Common alarms can indicate over-voltage, under-voltage, over-current, or temperature issues.
- Communication issues (RS232/RS485/CAN):
- Verify communication cables are correctly connected to the specified ports.
- Check DIP switch settings for parallel configurations.
- Ensure the connected host computer or inverter is configured with the correct communication parameters.
Recovery Method for Short Circuit Protection: There are recovery methods such as "Charge Removal, Load Removal". Consult the full instruction manual or contact support for detailed steps.
7. Specifications
Detailed technical specifications for the DATOUBOSS LFP48-300-FSD LiFePO4 Battery.

Figure 8: Technical Parameters of the DATOUBOSS LiFePO4 Battery.
| Project | Specification | Project | Specification |
|---|---|---|---|
| Model | LFP48-300-FSD | Discharge Over-Temperature Protection | 50°C |
| Battery Capacity | 15.36kWh | Discharge Over-Temperature Protection Recovery | 45°C |
| Battery Internal Resistance | ≤10mΩ | Low Temperature Protection | -15°C |
| Single Battery Capacity | 300Ah | Low Temperature Protection Recovery | -10°C |
| Nominal Operating Voltage | 51.2V | Charging Overcurrent | 215A |
| Maximum Output Current | 210A | Discharge Overcurrent Protection | 215A |
| Max. Charging Current | 210A | Short Circuit Protection | Charge Removal, Load Removal |
| Max. Discharging Current | 210A | Overpressure Protection | 58.4V |
| Peak Charging Current | 215A / 2s | Overcharge Protection Recovery | 54.0V |
| Peak Discharging Current | 215A / 2s | Overdischarge Protection | 43.2V |
| Parallel Capability | Up to 15 units | Overdischarge Protection Recovery (within 30 seconds) | 48V (tunable) |
| Communication Protocols | RS232, RS485, CAN | Charging Over-Temperature Protection | 50°C |
| Cycle Life (25°C) | ≥8000 Cycle, 70% SOH | Charge over-temperature protection recovery | 45°C (tunable) |
| Cycle Life (45°C) | ≥3000 Cycle, 70% SOH | Charging Low Temperature Protection | 0°C (tunable) |
| Recommend Charging Temperature | 0°C to 50°C | Charge Cryoprotection Recovery | 5°C |
| Recommend Discharging Temperature | -15°C to 50°C | Amount Of Electricity Shipped | 40% to 60% |
| Sizes (LxWxH) | 453x260x875mm | Equalization | Passive equilibrium |
| Weights | 110kg | Power Off Self-Consumption | ≤300uA |
8. User Tips
While no specific user reviews or Q&A were provided, here are some general tips for maximizing the performance and lifespan of your LiFePO4 battery system:
- Optimal Temperature: Operate the battery within the recommended charging (0°C to 50°C) and discharging (-15°C to 50°C) temperature ranges for best performance and longevity.
- Regular Monitoring: Periodically check the battery's state of charge, voltage, and temperature via the touch screen to catch potential issues early.
- Proper Sizing: Ensure your inverter and charging sources are appropriately sized for the battery's capacity and current limits.
- Firmware: Keep the battery management system (BMS) firmware updated to benefit from the latest optimizations and bug fixes.
9. Warranty and Support
For warranty information, technical support, or service requests, please refer to the contact details provided in the original product packaging or on the DATOUBOSS official website. Keep your purchase receipt as proof of purchase.