LCTC LC908 PID Temperature Controller Instruction Manual

Model: LC908 | Brand: LCTC

1. Introduction

The LCTC LC908 PID Temperature Controller is a versatile and high-precision device designed for industrial temperature control applications. It features a segment LCD display with high brightness backlight and a wide viewing angle for clear readability. This controller supports various thermocouple (TC) and resistance temperature detector (RTD) inputs and offers multiple output types including Relay, SSR, 4-20mA, and 0-10V. Equipped with RS485 communication, it allows for integration into larger control systems. The LC908 provides accurate temperature measurement and control with a 0.2% F.S. accuracy and a fast sampling time of 0.5 seconds.

LCTC LC908 PID Temperature Controller front view
Figure 1: LCTC LC908 PID Temperature Controller Front View

2. Setup and Installation

2.1 Physical Installation

The LC908 temperature controller is designed for panel mounting. The standard panel size is 96x96mm. Ensure adequate space for ventilation around the unit to prevent overheating.

LCTC LC908 PID Temperature Controller dimensions
Figure 2: LC908 Controller Dimensions (96x96mm panel size shown)

2.2 Wiring Diagram

Proper wiring is crucial for safe and correct operation. Refer to the general connection diagrams below and always consult the stickers on the side of your specific controller for detailed connection instructions in your field application.

General wiring diagram for LCTC LC908 PID Temperature Controller
Figure 3: General Wiring Diagram (Example for 48x48mm, 72x72mm, and 96x96mm models)
Detailed wiring diagram for LCTC LC908 PID Temperature Controller
Figure 4: Detailed Wiring Diagram (Illustrates output types and RS485 connections)

Key Wiring Points:

  • Power Supply: Connect to terminals 11 and 12 (AC 85-265V).
  • Input (TC/RTD): Connect your thermocouple or RTD sensor to the designated input terminals (e.g., 20, 21, 22, 23 for RTD; 16, 17 for TC). Ensure correct polarity for thermocouples.
  • Output: Connect your control device (heater, cooler, etc.) to the appropriate output terminals based on your model (Relay, SSR, 4-20mA, 0-10V).
  • RS485 Communication: Connect A+ and B- to the corresponding terminals for RS485 communication.
  • Alarms: If equipped, connect alarm outputs to external alarm indicators or systems.

2.3 Power Connection

The controller operates on an AC power supply ranging from 85V to 265V at 50-60Hz. Ensure the power source matches these specifications before connecting. Always turn off the main power supply before making any electrical connections to prevent electric shock or damage to the device.

3. Operating Instructions

3.1 Basic Operation

The front panel of the LC908 features a segment LCD display and several buttons for operation:

  • SET: Used to enter parameter setting mode and confirm selections.
  • A/M: Toggles between Automatic and Manual control modes.
  • F1, F2, F3 (Arrow Buttons): Used to navigate menus, adjust parameter values, and select options.

Upon powering on, the controller will display the Process Value (PV) and Set Value (SV). The PV indicates the current measured temperature, while the SV is your desired target temperature.

3.2 Input Type Configuration

The LC908 supports universal input types including K, J, E, T, S type thermocouples and PT100, Cu100, Cu50 RTDs. The input type can be selected and configured within the controller's menu settings. Refer to the detailed parameter list in the full manual for specific menu navigation.

3.3 Output Types

The controller offers various output options:

  • Relay Output: For switching higher power loads.
  • SSR Output: For solid-state relay control, offering faster switching and longer lifespan.
  • 4-20mA Output: Analog current output for proportional control.
  • 0-10V Output: Analog voltage output for proportional control.

The specific output type of your controller is determined at the time of order. Ensure your connected equipment is compatible with the controller's output type.

3.4 Alarm Configuration

The LC908 can be configured with up to two alarm outputs. These alarms can be set to trigger based on deviations from the set value or absolute temperature limits. Alarm parameters are configured through the menu system.

3.5 RS485 Communication

The controller includes an RS485 communication interface, allowing it to be integrated into a Modbus-RTU network for remote monitoring and control via a PLC or other master device. Ensure correct wiring and address settings for proper communication.

Video 1: Demonstration of PID control functionality with the LC908 controller.

4. Maintenance

4.1 General Care

  • Keep the controller clean and free from dust and debris. Use a soft, dry cloth for cleaning.
  • Avoid exposing the unit to direct sunlight, excessive heat, or extreme cold.
  • Ensure all wiring connections remain secure. Periodically check for loose connections.

4.2 Environmental Conditions

The LC908 is designed to operate in environments with temperatures between 0-50°C and humidity below 85% (non-condensing). Operating outside these conditions may affect performance and lifespan.

5. Troubleshooting

If you encounter issues with your LCTC LC908 PID Temperature Controller, consider the following common troubleshooting steps:

  • No Power: Check the power supply connections (85-265VAC) and ensure the power source is active.
  • Incorrect Temperature Reading: Verify the sensor wiring (TC/RTD) for correct polarity and secure connections. Ensure the input type is correctly configured in the controller's menu to match your sensor.
  • No Control Output: Check the output wiring to your heating/cooling element. Confirm the control mode (Automatic/Manual) is set appropriately and that the set value (SV) is correctly configured.
  • Communication Issues (RS485): Verify RS485 wiring (A+, B-), ensure correct baud rate and device address settings, and check for conflicts with other devices on the bus.
  • Controller Not Responding: Try power cycling the unit. If the issue persists, consult the full product manual for advanced diagnostics or contact technical support.

6. Specifications

FeatureSpecification
Brand NameLCTC
ModelLC908
OriginMainland China
CertificationCE
Power Supply85-265VAC, 50-60Hz
Input TypesTC (K, J, E, T, S), RTD (PT100, Cu100, Cu50) - configurable
Output TypesRelay / SSR / 4-20mA / 0-10V (model dependent)
Panel Size96x96mm
Accuracy0.2% F.S.
Sampling Time0.5 Sec
CommunicationRS485 (Modbus-RTU)
AlarmsMax 2 alarms (optional)
Transmission OutputPV: 4-20mA, PV: 0-10VDC (optional)
Operating Environment0-50°C, Humidity <85% (non-condensing)
Battery IncludedYes
High-concerned chemicalNone

7. User Tips

  • Initial Calibration: For critical applications, consider performing an initial calibration of your sensor and controller to ensure maximum accuracy.
  • Parameter Understanding: Familiarize yourself with all configurable parameters in the menu. Understanding each setting's function will allow for optimal performance and customization for your specific process.
  • Safety First: Always disconnect power before making or changing any wiring connections.

8. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. Keep your purchase receipt and product model number (LC908) handy for faster assistance.

© 2024 LCTC. All rights reserved.