ANENG AOS03

ANENG AOS03 3-in-1 Oscilloscope Multimeter User Manual

Model: AOS03

1. Introduction

The ANENG AOS03 is a versatile 3-in-1 handheld device that integrates the functions of an oscilloscope, a multimeter, and a signal generator. Designed with a dual injection molding process, it features a compact size, convenient portability, and flexible operation. The device is equipped with a 3.5-inch IPS full-view color display, providing clear readings in various lighting conditions. With its superior performance and powerful functionality, the AOS03 is suitable for a wide range of electrical measurement and testing scenarios.

ANENG AOS03 3-in-1 Oscilloscope Multimeter Signal Generator
Figure 1.1: ANENG AOS03 3-in-1 Oscilloscope Multimeter with its core functions highlighted.
ANENG AOS03 Function 3 in 1 display
Figure 1.2: The AOS03 displaying its three primary functions: oscilloscope, multimeter, and signal generator output.

2. Package Contents

Before using the device, please verify that all items are present in the package:

ANENG AOS03 Accessories List
Figure 2.1: Complete accessories list for the ANENG AOS03.
  1. 3-in-1 Oscilloscope Multimeter (Main Unit)
  2. User Manual (x2)
  3. Storage Bag
  4. Packaging Box
  5. Extra Tip Pen
  6. Oscilloscope Pen
  7. Positioning Sleeve (x2)
  8. Tag Ring (x8)
  9. USB Data Cable
  10. Probe Compensation Screwdriver
  11. Alligator Clip Ground Lead

3. Device Layout and Controls

Familiarize yourself with the various parts and controls of your ANENG AOS03 device:

ANENG AOS03 Labeled Diagram with Dimensions
Figure 3.1: Detailed diagram of the ANENG AOS03 with labeled components and dimensions.
  1. Dual channel input
  2. 3.5-Inch VA reverse color screen
  3. USB charging port/data cable connection
  4. Square wave input/ground terminal
  5. Corresponds to the function menu selection button at the top of the screen (F1-F4)
  6. Long press the switch/multimeter function to place an order and press as the relative value
  7. Automatic waveform measurement/manual range switching
  8. Keep current data/Long press to save measurement data
  9. Switching oscilloscope/multimeter
  10. Set value adjustment (Up/Down)
  11. Set the value to the left/previous page
  12. Set the value to the right/next page
  13. 10A current jack
  14. mA current jack
  15. Black watch pen negative jack (COM)
  16. Red watch pen negative jack (VΩHz-f)
  17. Back support frame
  18. Anti-drop silicone layer

4. Setup and Initial Use

4.1 Charging the Device

The AOS03 is equipped with a built-in 3400mAh 3.7V 18650 lithium battery, which can be recharged using the provided Type-C data cable. Connect the Type-C cable to the USB charging port (3) on the device and to a suitable USB power source.

ANENG AOS03 Lithium Battery Direct Charging
Figure 4.1: Charging the AOS03 via its Type-C USB port.

4.2 Power On/Off

Press the power button (6) to turn the device on or off. The device supports automatic shutdown after a period of inactivity to conserve battery life. This setting can be configured in the menu.

4.3 Language Selection

The device supports both Chinese and English languages. You can switch the language through the device settings menu.

5. Operating Instructions

5.1 Multimeter Function

The multimeter function allows for precise measurement of various electrical parameters. To switch to multimeter mode, press the dedicated oscilloscope/multimeter switch button (9).

ANENG AOS03 AC/DC Voltage Measurement
Figure 5.1: Examples of AC and DC voltage measurements using the multimeter function.
  • AC Voltage (V): Connect the test leads to the VΩHz-f and COM jacks. Select the AC voltage gear and measure across the circuit.
  • DC Voltage (V): Connect the test leads to the VΩHz-f and COM jacks. Select the DC voltage gear and measure across the circuit, observing polarity.
ANENG AOS03 AC/DC Current, Diode, Resistance Measurement
Figure 5.2: Examples of AC/DC current, diode, and resistance measurements.
  • AC Current (A): Connect the test leads to the 10A or mA jack and COM. Select the appropriate AC current gear and measure in series with the circuit.
  • DC Current (A): Connect the test leads to the 10A or mA jack and COM. Select the appropriate DC current gear and measure in series with the circuit.
  • Diode Test: Enter the diode gear, touch the positive and negative electrodes of the diode with the test leads.
  • Resistance (Ω): Enter the resistance gear, measure the resistance value on both sides of the component.
ANENG AOS03 Capacitance and Buzzer Measurement
Figure 5.3: Examples of capacitance and buzzer continuity measurements.
  • Capacitance (F): Enter the capacitor gear and contact both ends of the capacitor. For safety reasons, it is necessary to short-circuit the capacitor before measurement.
  • Buzzer (Continuity): Enter the buzzer gear, detect on and off, and issue a beep, indicating that the fuse line is unobstructed.

5.2 Oscilloscope Function

The oscilloscope function allows for real-time waveform visualization and analysis. To switch to oscilloscope mode, press the dedicated oscilloscope/multimeter switch button (9).

5.2.1 Dual Channel Waveform Detection

The AOS03 supports dual-channel input (CH1 and CH2), enabling simultaneous display and comparison of two waveforms. This feature enhances problem diagnosis and signal detection accuracy.

ANENG AOS03 Dual Channel Input Ports
Figure 5.4: Dual channel input ports for oscilloscope function.

Set and connect to the dual-channel input port, select automatic or manual measurement, and press the SAVE button (8) for 2 seconds to save the waveform.

ANENG AOS03 Single Channel vs Dual Channel Comparison
Figure 5.5: Comparison illustrating the advantage of dual-channel measurement over single-channel.

5.2.2 XY Display Mode

To enter XY display mode, navigate to the fifth page of the extended function menu. Press F1 to select X-Y. This mode displays the frequency relationship between CH1 and CH2, producing Lissajous figures of various shapes.

ANENG AOS03 XY Display Mode Examples
Figure 5.6: Examples of Lissajous figures in XY display mode.

5.2.3 Computer View Waveform

The AOS03 allows you to view saved waveforms on a computer. Enter the menu on the third page, press F3 to enter the data saving mode. Connect the device to your computer using the USB data cable. The device will appear as a USB disk. Open the 'Pic' folder on the disk to view the saved waveform images.

ANENG AOS03 Computer View Waveform
Figure 5.7: Connecting the AOS03 to a computer to view saved waveforms.

5.3 Signal Generator Function

The built-in signal generator can output various waveforms for testing and calibration purposes.

5.3.1 Waveform Output

To output a signal waveform, enter the menu on the sixth page. Press F1 to enter the extended application, select 'signal output', and press the MENU key to confirm and start generating the waveform.

ANENG AOS03 Signal Waveform Output
Figure 5.8: The AOS03 configured for signal waveform output.

5.3.2 Available Waveforms

The signal generator supports the output of 7 different waveforms:

  • Sine wave
  • Square wave
  • Triangular wave
  • Half wave
  • Full wave
  • Sawtooth wave
ANENG AOS03 7 Signal Waveforms
Figure 5.9: Visual representation of the 7 signal waveforms generated by the AOS03.

6. Maintenance

6.1 Battery Care

The device uses a 3400mAh 3.7V 18650 lithium battery. To prolong battery life:

  • Charge the device regularly, especially when the low battery indicator is shown.
  • Avoid fully discharging the battery frequently.
  • Store the device in a cool, dry place if not used for extended periods.

6.2 Fuse Protection

The AOS03 features double fuse protection (10A 250V / 600mA 250V) for enhanced safety during current measurements. If the device stops functioning during current measurement, check the fuses. Fuse replacement should only be performed by qualified personnel.

ANENG AOS03 Lithium Battery and Fuse Protection
Figure 6.1: Internal view highlighting the lithium battery and double fuse protection.

6.3 Cleaning

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents, as they may damage the casing or screen.

7. Troubleshooting

7.1 Current Measurement Precaution

IMPORTANT: When measuring current, the multimeter must always be connected in series with the circuit. Incorrect connection (e.g., in parallel) can damage the device and the circuit.

ANENG AOS03 Current Measurement Diagram
Figure 7.1: Diagram illustrating the correct method for current measurement in series.

When measuring electric current, pay close attention to the connection method. Do not mix current and voltage measurement modes. Use the multimeter's current file, choose an appropriate range. If the current value is unknown, start with a larger range. If the multimeter displays "1", it indicates an over-range condition. Insert the red pen into the mA hole, the black pen into the COM hole, then disconnect the circuit and connect the pens in series to measure.

7.2 General Malfunctions

If the product is not operating properly, please provide a detailed video of the issue to ANENG customer service. Their experts can quickly diagnose the problem and provide a solution. This brand product is technical and requires a certain degree of electrical knowledge. If you encounter operational problems or do not understand how to use the product, please contact ANENG customer service for assistance.

7.3 Product Has Been Artificially Damaged

This device is primarily used to detect electrical and other measurement products. It requires careful use and adherence to operating procedures to prevent damage. If the device is used improperly and the use method is not equal, resulting in damage, it will be judged as man-made damage, which is not within the scope of after-sales service. However, you can still contact ANENG customer service to receive a certain amount of coupons to deduct the newly purchased ANENG products.

8. Specifications

8.1 General Technical Specifications for Multimeter

Parameter Value
Display (IPS) 25000 counts
Range Automatic/Manual
Material ABS+TPE
Sampling Rate 3 times per second
True RMS
Data Hold
Screen Backlight
Low Battery Indicator
Auto Power Off
Battery Included Yes
IS Battery Demountable Yes
Record Length 128kbyte
Digital Channels 2
Display Resolution 800*600 Pixels
Display Size 3.0 - 4.9 Inches (3.5-inch)
Origin Mainland China
DIY Supplies Electrical
ANENG AOS03 Multimeter Technical Indicators Table
Figure 8.1: Detailed multimeter technical indicators.

8.2 Oscilloscope Technical Indicators

Characteristic Explain Characteristic Explain
Bandwidth 50MHz Sensitivity 20mV/div-10V/div
Sampling Method Real-time sampling Offset Range 4 grids (positive and negative)
Sampling Rate 200M/280MSa/s Analog Bandwidth 50MHz
Channel 2 Dual channel Low-frequency More than 10Hz
Input coupling DC, AC Rise time Less than 10ns
Input impedance 1MΩ,@16pf DC gain accuracy ±3%
Attenuation X1,X10 Auto measurement Period/Frequency/Peak/Maximum/Minimum/RMS/Duty Cycle/Number of Pulses
Maximum input voltage X1range<150V,X10range<300V(DC+AC peak) Trigger Modes Auto, normal, single
Rate Range 1.5Sa/s-280MSa/s Trigger Edges Rising edge, falling edge
Interpolation (sinx)x Operating mode Normal mode 200MSa/s, High-speed mode 280MSa/s
Sweep range 10ns/div-20s/div Display mode YT / XY / Roll
Time Base 20ppm Afterglow mode Minimum, 500ms, 1S, 10S, Infinite
Record length Up to 128kbyte Signal generator output Sine wave/square wave/sawtooth wave/half wave/full wave
ANENG AOS03 Oscilloscope Technical Indicators Table
Figure 8.2: Detailed oscilloscope technical indicators.

8.3 Environmental Specifications

Parameter Value
Operating Temperature 0~40℃
Operating Humidity <75%
Storage Temperature -20~60℃
Storage Humidity <80%
Battery Type 18650 battery*1

9. User Tips

  • Always ensure the device is fully charged before critical measurements to avoid interruptions.
  • For precise oscilloscope readings, use the probe compensation screwdriver to calibrate your probes if necessary.
  • When saving waveforms to a computer, ensure the USB connection is stable to prevent data corruption.
  • Take advantage of the dual-channel feature for comparing signals, which can greatly assist in circuit analysis and troubleshooting.
  • Regularly check the test leads for any signs of wear or damage to ensure accurate and safe operation.

10. Warranty and Support

ANENG is committed to providing excellent after-sales service. If you have any questions or issues regarding your AOS03 device, please refer to the following guidelines:

ANENG After-Sales Support Information
Figure 10.1: Overview of ANENG's after-sales support process.

10.1 Contact for After-Sales Questions

If you have any questions during the use of the product, please contact ANENG customer service. Our customer service team will provide you with satisfactory solutions in a timely manner.

10.2 About Quality Issues

In case of quality problems other than "man-made damage" during the use of this product, replacement services or refunds can be provided. For specific product damage, please contact ANENG customer service to confirm and discuss solutions.

  • Replacement method: a) Replacement of spare parts, b) Replacement of the whole machine.
  • Refund method: a) Partial refund according to damaged parts, b) Full refund if the whole machine is damaged.

10.3 Replacement or Refund Request

To initiate a replacement or refund request:

  1. Contact customer service and provide a product quality problem video for damage determination.
  2. Negotiate a solution.
  3. Destroy (smash) products with quality problems to avoid secondary damage.
  4. Execute the solution.

ANENG AOS03 Dual Channel Oscilloscope Multimeter: Intelligent 3-in-1 Digital Test Tool

ANENG AOS03 Dual Channel Oscilloscope Multimeter: Intelligent 3-in-1 Digital Test Tool

0:31 • 1280×720 • visual_overview

Related Documents - AOS03

Preview ANENG AOS03 Oscilloscope Multimeter Signal Generator User Manual
Comprehensive user manual for the ANENG AOS03, a 2-channel oscilloscope, multimeter, and signal generator. Covers features, operation, safety, and technical specifications.
Preview ANENG SZ308 Digital Multimeter Operator's Instruction Manual
Comprehensive operator's instruction manual for the ANENG SZ308 Digital Multimeter, covering safety information, specifications, measurement functions, operating instructions, and maintenance.
Preview ANENG AOS02 Digital Oscilloscope Multimeter User Manual
This user manual provides comprehensive instructions and specifications for the ANENG AOS02 Digital Oscilloscope Multimeter, covering its features, operation, measurement functions, maintenance, and technical details.
Preview ANENG 616 Digital Multimeter: Operating Instructions and Specifications
Explore the ANENG 616 Digital Mini Multimeter with this comprehensive operating manual. It details safety precautions, button functions, measurement procedures for voltage, resistance, current, capacitance, frequency, and temperature, along with detailed electrical and environmental specifications.
Preview ANENG V04A Automatic Digital Multimeter User Manual
Comprehensive user manual for the ANENG V04A automatic digital multimeter, detailing its features, technical specifications, safe operation procedures, and maintenance guidelines.
Preview ANENG PN130 Digital Multimeter User Manual: Features, Specifications, and Operation Guide
Detailed user manual for the ANENG PN130 digital multimeter. Learn about its overview, general characteristics, comprehensive specifications for AC/DC voltage, current, resistance, capacitance, frequency, and operation instructions for accurate electrical measurements.