BSIDE U5

BSIDE U5 U-Shaped Clamp Meter Instruction Manual

Model: U5

1. Introduction

The BSIDE U5 U-Shaped Clamp Meter is a professional-grade electrical testing instrument designed for accurate and safe measurement of various electrical parameters. Featuring a unique U-shaped clamp design, True RMS capabilities, auto-ranging functionality, and a high-definition TFT screen, it is suitable for both professional electricians and DIY enthusiasts. This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your device.

BSIDE U5 Clamp Meter complete package
Figure 1: BSIDE U5 Clamp Meter complete package including the device, test leads, USB charging cable, and carrying case.

2. Safety Information

Please read and understand all safety warnings and operating instructions before using this instrument. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Always adhere to local and national safety codes.
  • Do not use the meter if it appears damaged or if the insulation on the test leads is compromised.
  • Ensure the meter is in the correct function and range before making measurements.
  • Avoid working alone when performing high-voltage measurements.
  • Keep fingers behind the finger guards on the test probes during use.
  • Do not apply more than the rated voltage, as marked on the meter, between the terminals or between any terminal and ground.
  • Use caution when working with voltages above 30V AC RMS, 42V peak, or 60V DC. These voltages pose a shock hazard.
  • Do not operate the meter in explosive gas, vapor, or dust environments.
  • Remove the test leads from the circuit before changing functions.

3. Product Overview

The BSIDE U5 Clamp Meter features a compact design with an intuitive interface. Below is a detailed description of its components:

Detailed diagram of the BSIDE U5 Clamp Meter's components and controls
Figure 2: Detailed diagram of the BSIDE U5 Clamp Meter's components and controls, front and back views.
  1. Current sensing area
  2. Non-contact voltage sensing area
  3. Flashlight
  4. Display screen
  5. USB charging port
  6. Non-contact voltage sensing (V-Alert)/flashlight switch
  7. AC/DC current switching button
  8. Automatic mode button
  9. Power button
  10. Hold key / Switch between Live and Neutral keys
  11. Reset DC base number / Reset data
  12. Left cut function key
  13. Right cut function key
  14. Input port

4. Initial Setup and Charging

4.1. Battery Charging

The BSIDE U5 is equipped with a built-in 3.7V 1200mAh lithium battery, which is rechargeable via a Type-C USB interface. To charge the device:

  1. Locate the USB charging port (5) on the device.
  2. Connect the provided Type-C USB cable to the meter and a suitable USB power source (e.g., computer, USB wall adapter).
  3. The charging indicator on the screen will show the charging status.

To access the battery compartment for maintenance or replacement (if necessary), the back cover can be unscrewed counterclockwise by 90 degrees. The body can then be turned over, tapped, and removed.

Instructions for charging the BSIDE U5 Clamp Meter via its Type-C USB port and removing the battery cover
Figure 3: Instructions for charging the BSIDE U5 Clamp Meter via its Type-C USB port and battery cover removal method.

5. Operating Modes and Measurements

The BSIDE U5 Clamp Meter offers a variety of measurement functions with intelligent features for ease of use and safety.

5.1. General Operation

The meter features a dual display on one screen and intelligent anti-burning protection. Measurements can be initiated immediately upon startup, as the gear position is automatically recognized. Voltage and frequency can be tested simultaneously.

BSIDE U5 Clamp Meter demonstrating dual display and intelligent anti-burning measurement
Figure 4: BSIDE U5 Clamp Meter demonstrating dual display and intelligent anti-burning measurement with test leads connected to a power outlet.

5.2. Measurement Functions

The BSIDE U5 is a fully functional multimeter capable of measuring:

  • Current (AC/DC)
  • Voltage (AC/DC)
  • Resistance
  • Capacitance
  • On-off continuity
  • Diode
  • Frequency
  • Duty Cycle
  • Neutral and Live Wire Identification (LIVE)
  • Non-Contact Voltage (NCV)
Overview of the BSIDE U5 Clamp Meter's fully functional capabilities
Figure 5: Overview of the BSIDE U5 Clamp Meter's fully functional capabilities.

5.3. Current Measurement (Clamp Jaw)

The 16mm large jaw design allows for easy and safe current detection of cables of various diameters without breaking the circuit.

Close-up view of the 16mm large jaw design
Figure 6: Close-up view of the 16mm large jaw design of the BSIDE U5 Clamp Meter, showing its ability to clamp around multiple electrical wires.

5.4. Non-Contact Voltage (NCV) Induction

The NCV function provides safe electrical measurement by detecting induced voltage without physical contact. It supports LIVE neutral and live wire identification, making power verification more convenient.

  • High Sensitivity (12-1KV AC): The buzzer emits a high-frequency alarm sound, and the analog bar shows a full grid.
  • Low Sensitivity (90-1KV AC): The buzzer emits a high-frequency alarm sound, and the analog bar shows two bars.
BSIDE U5 Clamp Meter demonstrating NCV induction with high sensitivity
Figure 7: NCV voltage induction with high sensitivity.
BSIDE U5 Clamp Meter demonstrating NCV induction with low sensitivity
Figure 8: NCV voltage induction with low sensitivity.

5.5. Display Features

The LCD high-definition digital display provides intuitive and clear readings, even in dim light, ensuring maximum visibility during operation.

BSIDE U5 Clamp Meter displaying 6000 digital display
Figure 9: BSIDE U5 Clamp Meter displaying "6000 digital display" for accurate True RMS measurements.

5.6. Measurement Demonstrations

Examples of various measurements:

Demonstration of DC voltage and AC voltage measurements
Figure 10: Demonstration of DC voltage and AC voltage measurements.
Demonstration of Resistance and On-off measurements
Figure 11: Demonstration of Resistance and On-off measurements.
Demonstration of Diode and Capacitance measurements
Figure 12: Demonstration of Diode and Capacitance measurements.

6. Specifications

Detailed technical specifications for the BSIDE U5 Clamp Meter:

Detailed product specification table for the BSIDE U5 Clamp Meter
Figure 13: Detailed product specification table for the BSIDE U5 Clamp Meter.
FunctionRangeResolutionAccuracy
1. DC Voltage
Direct current voltage (mV)60.00mV0.01mV±(1.0% reading +3 characters)
600.0mV0.1mV±(0.8% reading +3 characters)
DC voltage (V)6.000V0.001V±(0.8% reading +3 characters)
60.00V0.01V±(0.8% reading +3 characters)
600.0V0.1V±(0.8% reading +3 characters)
610V1V±(1.0% reading +3 characters)
2. AC Voltage
Alternating voltage (mV)60.00mV0.01mV±(1.2% reading +3 characters)
600.0mV0.1mV±(1.2% reading +3 characters)
Alternating voltage (V)6.000V0.001V±(1.2% reading +3 characters)
60.00V0.01V±(1.2% reading +3 characters)
600.0V0.1V±(1.2% reading +3 characters)
610V1V±(1.2% reading +5 characters)
3. Direct Current
1.0~600.0A0.1A±(2.5% reading +5 characters)
4. Alternating Current (>20A)
1~600.0A (40-999Hz)0.1A±(2.5% reading +5 characters)
5. Resistance
0.1Ω~599.9Ω0.1Ω±(1.2% reading +3 characters)
0.600KΩ~5.999KΩ0.001KΩ±(1.2% reading +3 characters)
0.600MΩ~5.999MΩ0.001MΩ±(2.0% reading +10 characters)
6.00MΩ~60.00MΩ0.01MΩ±(2.0% reading +10 characters)
6. Capacitor
0.010uF~599.9uF0.1uF±(3.5% reading +10 characters)
0.600mF~60.0mF0.01mF±(4.5% reading +10 characters)
7. Frequency (900mVrms to 20Vrms)
1.000Hz~99.99Hz0.01Hz±(2.0% reading +10 characters)
1.000KHz~99.99KHz0.01KHz±(2.5% reading +10 characters)
1.000MHz~9.999MHz0.001MHz±(3.0% reading +15 characters)
8. Duty Cycle
10.0%~95.0%0.1%±3.0%

General Specifications:

  • Weight: 170g
  • Dimensions: 222.4mm x 43.6mm x 30mm (approx. 8.7 x 1.7 x 1.2 inches)
  • Operating Temperature: 20-40°C
  • Display Type: Digital Only (6000 counts)
  • DIY Supplies: Electrical
  • Clamp Jaw Opening: 16mm
  • Battery: 3.7V 1200mAh Lithium (Included)
Diagram illustrating the size and weight of the BSIDE U5 Clamp Meter
Figure 14: Diagram illustrating the size and weight of the BSIDE U5 Clamp Meter.

7. Maintenance

7.1. Cleaning

Wipe the meter with a dry, soft cloth. Do not use abrasives or solvents.

7.2. Battery Care

The device uses a rechargeable lithium battery. To prolong battery life, charge it regularly and avoid fully discharging it for extended periods. If the meter is not used for a long time, it is recommended to charge it periodically.

7.3. Automatic Shutdown

The instrument features an automatic shutdown function. If there is no signal input for approximately 10 minutes, the meter will automatically power off to conserve battery life.

8. Troubleshooting

This section provides solutions to common issues you might encounter with your BSIDE U5 Clamp Meter.

  • Diode Measurement: Diodes with a voltage less than 3V are automatically recognized by the meter.
  • Continuity (On-off) Test: When the measured resistance is less than 50Ω, the buzzer will sound, indicating continuity.
  • LIVE Wire Identification: When the LIVE wire is identified, the simulation bar on the display will be full, and the buzzer will sound. If testing a neutral wire, there will be no response.
  • No Display/Power: Ensure the battery is charged. If the issue persists, check the USB charging connection.
  • Inaccurate Readings: Ensure the test leads are properly connected and the correct function/range is selected. Avoid strong electromagnetic interference.

9. User Tips

  • For current measurements, ensure the conductor is placed centrally within the clamp jaw for the most accurate reading.
  • Utilize the NCV function for quick and safe detection of live wires before performing any contact measurements.
  • The auto-ranging feature simplifies operation, but always double-check the displayed units and magnitude for safety.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the contact information provided by your retailer or the manufacturer's official website. Keep your purchase receipt as proof of purchase for warranty claims.


BSIDE U5 Open-Type Current Multimeter: AC/DC Voltage & Current Clamp Meter

BSIDE U5 Open-Type Current Multimeter: AC/DC Voltage & Current Clamp Meter

0:50 • 720×1280 • demonstration

Related Documents - U5

PreviewBSIDE S10/S11 Smart Digital Multimeter User Manual
Comprehensive guide for the BSIDE S10/S11 Smart Digital Multimeter, covering safety warnings, product structure, button descriptions, technical specifications, operating instructions, and maintenance. Learn how to measure DC/AC voltage, resistance, capacitance, continuity, frequency, duty cycle, and perform NCV and LIVE wire detection.
PreviewBSIDE A10 Digital Multimeter User Manual and Specifications
Comprehensive user manual and technical specifications for the BSIDE A10 digital multimeter, covering operation, safety, features, and warranty information.
PreviewBSIDE A1 Digital Multimeter User Manual and Specifications
Comprehensive user manual for the BSIDE A1 digital multimeter, covering technical specifications, safety instructions, operation, and warranty information. Learn how to use your BSIDE A1 for accurate electrical measurements.
PreviewBSIDE A5X Voltage Detector Multimeter User Manual
Comprehensive user manual for the BSIDE A5X Voltage Detector Multimeter, detailing its features, specifications, operation instructions, and maintenance. Includes safety information and technical specifications.
PreviewBSIDE S20 Digital Multimeter User Manual and Specifications
Comprehensive user manual for the BSIDE S20 digital multimeter, covering technical specifications, operation, safety instructions, and warranty information.
PreviewBSIDE S10/S11 Digital Multimeter User Manual and Specifications
Comprehensive user manual and technical specifications for the BSIDE S10 and BSIDE S11 digital multimeters, covering operation, safety, features, and warranty. Includes detailed instructions and product information.