OWON HSA2000 Series

Contents

OWON HSA2000 Series Handheld 3-in-1 Spectrum Analyzer User Manual

Model: HSA2000 Series

Brand: OWON

1. Introduction

The OWON HSA2000 Series is a versatile handheld 3-in-1 device combining a Spectrum Analyzer, a Digital Oscilloscope, and a 4.5-Digit Multimeter. Designed for portability and comprehensive electronic testing, it offers a wide range of functionalities for various applications.

Key Features:

  • All-in-One: Spectrum Analyzer + Oscilloscope + Multimeter
  • Spectrum Analyzer: Max. 9kHz to 3GHz frequency range, 100Hz frequency resolution.
  • Oscilloscope: 70MHz-200MHz bandwidth, 250MSa/s sampling rate, 8K memory depth, up to 10,000wfrms/s waveform refresh rate, supports auto measurements.
  • Multimeter: 4 1/2 digits multimeter, supports standard measurements of voltage, current, resistance, capacitance, diode, and continuity testing.
  • Standard USB Type-C interface for PC communication.

2. Setup Guide

2.1 Unpacking and Initial Inspection

Carefully unpack all components from the packaging. Verify that all items listed below are present and undamaged. If any items are missing or damaged, please contact customer support.

OWON HSA2000 Series with included accessories: probes, power adapter, USB cable, and carrying case.
Figure 2.1: OWON HSA2000 Series and its accessories.

2.2 Powering the Device

  1. The device can be powered via the included power adapter or its internal battery.
  2. To charge the device, connect the USB Type-C cable to the device and the power adapter, then plug the adapter into a power outlet. The charging indicator will illuminate.
  3. Press and hold the power button to turn the device ON or OFF.

2.3 Connecting Probes and Leads

Depending on the function you intend to use (Oscilloscope, Multimeter, or Spectrum Analyzer), connect the appropriate probes or leads to the device's input ports.

  • Oscilloscope: Connect oscilloscope probes to the BNC connectors.
  • Multimeter: Connect multimeter test leads to the designated input jacks (VΩmA, COM, 10A).
  • Spectrum Analyzer: Connect the RF antenna or probe to the RF input connector.
Front view of the OWON HSA2000 Series handheld device showing screen, buttons, and input ports.
Figure 2.2: Front panel with input ports and controls.

3. Operating Instructions

The HSA2000 Series features a user-friendly interface with dedicated buttons and a clear LCD display for easy navigation between its three primary functions.

3.1 Mode Selection

Use the mode selection buttons (typically labeled "Scope", "Spectrum", "Multimeter") to switch between the different instrument modes.

3.2 Digital Oscilloscope Operation

  1. Select the "Scope" mode.
  2. Connect the oscilloscope probes to the circuit under test.
  3. Adjust the Vertical Scale (V/div) and Time Base (s/div) settings using the dedicated knobs or menu options to display the waveform clearly.
  4. Use the trigger settings (Edge, Auto, Normal, Single) to stabilize the waveform.
  5. Utilize automatic measurement functions (Period, Frequency, PK-PK, etc.) for quick analysis.
OWON HSA2000 Series display showing an oscilloscope waveform.
Figure 3.1: Oscilloscope mode display.

3.3 Spectrum Analyzer Operation

  1. Select the "Spectrum" mode.
  2. Connect the RF input to the signal source.
  3. Set the Center Frequency, Span, and Reference Level according to your measurement requirements.
  4. Adjust the Resolution Bandwidth (RBW) and Video Bandwidth (VBW) for optimal signal visualization.
  5. Observe the frequency spectrum on the display to identify signal components and their power levels.
OWON HSA2000 Series display showing a spectrum analysis.
Figure 3.2: Spectrum Analyzer mode display.

3.4 Multimeter Operation

  1. Select the "Multimeter" mode.
  2. Connect the test leads to the appropriate input jacks and to the component or circuit you wish to measure.
  3. Select the desired measurement function (Voltage, Current, Resistance, Capacitance, Diode, Continuity) using the function buttons.
  4. Read the measurement value on the digital display.
OWON HSA2000 Series display showing multimeter readings.
Figure 3.3: Multimeter mode display.

3.5 PC Communication

Connect the device to a PC using the USB Type-C cable. Install the necessary drivers and software (available from the manufacturer's website) to enable data transfer, remote control, and waveform analysis on your computer.

4. Maintenance and Care

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Battery Care: For prolonged storage, ensure the battery is charged to approximately 50%. Recharge periodically if stored for long periods.
  • Probe Care: Inspect probes and leads regularly for damage. Replace worn or damaged accessories to ensure accurate measurements and safety.

5. Troubleshooting

ProblemPossible CauseSolution
Device does not power on.Low battery or power adapter issue.Ensure the device is fully charged or connected to a working power adapter. Check power button operation.
No signal displayed on Oscilloscope/Spectrum Analyzer.Incorrect probe connection, wrong settings, or no input signal.Verify probes are correctly connected. Adjust vertical scale, time base, and trigger settings. Confirm signal source is active.
Multimeter readings are inaccurate.Damaged test leads, incorrect function selected, or out of calibration.Check test leads for continuity and damage. Ensure the correct measurement function is selected. If issues persist, consider calibration.
PC communication failure.Incorrect USB cable, missing drivers, or software issues.Use the provided USB Type-C cable. Install the latest drivers and software from OWON's official website. Restart both device and PC.

6. Technical Specifications

6.1 Digital Oscilloscope Specifications

ModelHSA2105HSA2307HSA2310HSA2320
Bandwidth50MHz70MHz100MHz200MHz
Max Sample Rate250MSa/s500MSa/s1GSa/s
ChannelDual
Acquisition ModelSample, Peak
Record Length8K
Waveform Refresh Rate10000wfrms/s
Probe Attenuation1X, 10X, 100X, 1000X, 10000X
Sample Rate Range5ns/div - 1000s/div, Step by 1-2-5
Vertical Resolution10mV/div - 10V/div
Trigger TypeEdge
Trigger ModelAuto, Normal, Single
Cursor Measurement△V, △T
Automatic MeasurementPeriod, Frequency, Mean, PK-PK, Max, Min, RMS, Rise Time, Fall Time, +Width, -Width

6.2 Spectrum Analyzer Specifications

ParameterHSA2000 Series (1.5GHz)HSA2000 Series (3GHz)
Frequency Range9kHz to 1.5GHz9kHz to 3GHz
Frequency Resolution100Hz
Frequency sweep rangezero span, 300Hz to the maximum frequency of the instrument
Continuous power+20 dBm (100mW)
SSB Phase Noise (20℃-30℃, fc=1GHz)< -60dBc/Hz (type) @10kHz, offset
< -62dBc/Hz (type) @100kHz, offset
Resolution Bandwidth (-3dB)200 Hz to 850 kHz, steps by 200Hz-1-3-10-30-100-300-600-850kHz
DANL (input attenuation@0 dB, RBW = VBW = 100Hz, 20℃ to 30℃, input impedance = 50Ω)<-120dBm (10MHz to 1.5GHz)<-120dBm (10MHz to 2GHz)
-<-115dBm (2GHz to 3GHz)

6.3 Multimeter Specifications

ParameterValueParameterValue
Display4 1/2 digits (max 20000 count)Testing ModesVoltage, Current, Resistance, Capacitance, Diode, Continuity
Input Resistance10MΩDiode0-2V
DC Voltage20.000mV - 1000.0VAC Voltage20.000mV - 750.00V
DC Current20.000mA - 10.000AAC Current20.000mA - 10.000A
Resistance200.00Ω - 100.00MΩCapacitance2.000nF - 2.00mF

6.4 General Specifications

ParameterValue
Display3.5 inch LCD
Communication InterfaceUSB TYPE-C
PowerPower adapter or Battery
Dimension (W x H x D)96 × 198 × 38 mm
Device Weight0.6kg

7. User Tips

  • Battery Optimization: To maximize battery life, reduce screen brightness when not in critical use.
  • Software Updates: Regularly check the OWON official website for firmware updates to ensure optimal performance and access to new features.
  • Probe Calibration: For precise measurements, especially with the oscilloscope, perform probe compensation/calibration as needed.
  • Environmental Conditions: Avoid using the device in environments with excessive dust, moisture, or extreme temperatures to prevent damage and ensure longevity.

8. Warranty and Support

For detailed warranty information, technical support, and further operational guidance, please refer to the official user manual PDF and the manufacturer's website.

Official User Manual (PDF): A comprehensive user manual is available for download. Please refer to the following link for the PDF document: OWON HSA2000 Series User Manual PDF

Manufacturer Support: For any technical inquiries, service requests, or warranty claims, please contact OWON customer support through their official website or authorized service centers.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.