This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Sumry 4KW Hybrid Inverter. Please read this manual thoroughly before installation and use, and keep it for future reference.

The Sumry 4KW Hybrid Inverter is an off-grid pure sine wave solar inverter designed for home use. It features a 140A MPPT solar charger, supports a maximum PV input of 5600W, and operates at 24V. It offers a 6.25-inch LCD display for easy monitoring and configuration.

Sumry 4KW Hybrid Inverter connected to batteries and solar panels, showing 140A PV Max and 110A AC Max, compatible with 24V GEL, FLD, LI, USE batteries.
Figure 1: Sumry 4KW Hybrid Inverter with key specifications and battery compatibility.
Sumry 4KW Hybrid Inverter in a natural setting, with images of household appliances like a fridge, air conditioner, washing machine, microwave oven, and an RV, indicating diverse applications.
Figure 2: The Sumry Hybrid Inverter can power various household appliances and is suitable for diverse environments.

2. Safety Information

Always follow basic safety precautions to reduce the risk of fire, electric shock, and injury to persons.

  • Ensure proper grounding of the inverter.
  • Do not disassemble the inverter. Refer servicing to qualified personnel.
  • Keep the inverter away from flammable materials and moisture.
  • Ensure adequate ventilation around the inverter to prevent overheating.
  • Always disconnect all power sources (PV, utility, battery) before performing any maintenance or wiring.

3. Installation

3.1 Unboxing and Initial Inspection

Upon receiving your inverter, carefully unpack it and inspect for any shipping damage. Ensure all components are present as per the packing list.

Video 1: Unboxing and initial wiring demonstration of the Sumry Hybrid Inverter.

3.2 Circuit Breaker Specifications

For the Sumry HGX 4KW inverter, specific circuit breakers are required for safety and optimal performance:

  • Battery to Inverter: 2P200A circuit breaker.
  • Photovoltaic (PV) Input to Inverter: 2P20A circuit breaker.
  • Utility Input to Inverter: 2P63A circuit breaker.
  • Inverter Output: 2P40A circuit breaker.
Diagram showing recommended circuit breaker specifications for a Sumry 4KW Hybrid Inverter: 2P200A for battery, 2P20A for PV, 2P63A for utility, and 2P40A for output.
Figure 3: Recommended circuit breaker specifications for the inverter connections.

3.3 Wiring Steps

  1. Battery Connection: Install a 2P200A circuit breaker between the battery and the inverter. Ensure the circuit breaker is open. Connect the 24V battery to the inverter's battery terminals (positive to positive, negative to negative). Close the circuit breaker and measure the voltage on the inverter's battery side to confirm it's normal.
  2. PV Input Connection: Install a 2P20A circuit breaker between the PV input and the inverter. Ensure the circuit breaker is open. Connect the solar panels to the PV input terminals. Once the battery voltage is confirmed normal, close the PV input circuit breaker. The inverter display should light up and begin charging.
  3. AC Input and Output Connection: Install a 2P63A circuit breaker between the AC input (utility grid) and the inverter. Install a 2P40A circuit breaker between the inverter's output and your home appliances. Turn on both AC input and output circuit breakers. Connect the inverter to the mains. After 2 minutes, turn off the mains input circuit breaker, then turn off the inverter output circuit breaker. This completes the installation procedure.
Wiring diagram for the Sumry Hybrid Inverter, showing connections for solar modules, photovoltaic box, generator, utility grid, external battery packs, and home appliances, with a circuit protector.
Figure 4: Comprehensive wiring diagram for the hybrid inverter system.

3.4 Solar Panel Connection Guidelines

The Sumry HGX series inverter has a maximum PV charging power of 5600W and a PV charging voltage range of 55-350Vdc. When connecting solar panels, consider the voltage and power of individual panels to ensure they fall within the inverter's acceptable range.

Diagram illustrating series and parallel wiring methods for solar photovoltaic panels. Series connection increases voltage (e.g., 6 panels at 41.92V each = 251.52V). Parallel connection increases current (e.g., 2 strings of 3 panels in parallel = 20.7A). PV cable dimensions: 6-8A/mm².
Figure 5: Solar photovoltaic panel wiring methods (series and parallel).

4. Operation

4.1 Display and Controls

The inverter features a 6.25-inch LCD display and touchable buttons for user interaction. The display shows input/output voltage, battery status, load, and charging status.

4.2 Working Modes

The inverter offers versatile working modes to optimize power management:

  • Charging Modes:
    • Only Solar: Prioritizes solar power for charging.
    • Solar First: Solar power is the primary charging source, supplemented by utility if needed.
    • Mains & Solar: Both utility and solar power are used for charging.
  • Output Modes:
    • SBU (Solar-Battery-Utility): Prioritizes solar, then battery, then utility for powering loads.
    • SUB (Solar-Utility-Battery): Prioritizes solar, then utility, then battery for powering loads.
Diagram showing three safe charging modes (Solar First, Solar and Utility, Only Solar) and two output modes (SUB, SBU) for the Hybrid Solar Inverter, suitable for different needs and scenarios.
Figure 6: Input (charging) and Output modes of the hybrid solar inverter.

4.3 Pure Sine Wave Output

The inverter provides a pure sine wave output, ensuring high compatibility with over 98% of electrical appliances, making it efficient and stable for sensitive electronics.

Comparison between Modified Sine Wave (lower stability) and Pure Sine Wave (high compatibility) output, showing a computer setup powered by a pure sine wave inverter.
Figure 7: Pure Sine Wave output ensures high compatibility with appliances.

4.4 Battery Compatibility

The inverter is compatible with various 24V battery types, including Lithium, Gel, LiFePO4, Lead-acid, and AGM batteries. It also features built-in lithium battery automatic activation.

Diagram showing the Sumry Hybrid Inverter compatible with multiple battery types: FLD (Flooded), GEL, LI (Lithium-ion phosphate, Lithium-ion), SLD (AGM/Sealed), and USER (User custom Battery).
Figure 8: The inverter supports a wide range of battery types.

4.5 Monitoring and Communication

The inverter supports communication via RS232/RS485. An optional WiFi monitoring function is available, allowing you to monitor and control the system via a smart app. Note that only one communication method (WiFi module or battery BMS) can be used at a time. If using battery BMS, ensure it supports PACE or PYLONTECH protocols.

Image showing a smartphone app displaying inverter status and an optional WiFi module connected to the inverter, indicating remote monitoring capabilities.
Figure 9: Monitor and control your inverter via a smart app with the optional WiFi module.

5. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter.

  • Cleaning: Keep the inverter's ventilation openings clear of dust and debris. Use a dry cloth to clean the exterior.
  • Connections: Periodically check all electrical connections for tightness and corrosion. Loose connections can cause overheating and damage.
  • Battery Health: Monitor battery voltage and health regularly, especially if using lead-acid batteries.
  • Environment: Ensure the inverter is installed in a dry, well-ventilated area, away from direct sunlight and extreme temperatures.

The inverter includes intelligent fans to enhance battery performance and reduce heat, contributing to system longevity.

6. Troubleshooting

The inverter is equipped with various protection features. If an issue occurs, the LCD display may show an error code or fault indicator.

  • Overload Protection: If the load exceeds the inverter's capacity, it will shut down. Reduce the load and restart the inverter.
  • Over-temperature Protection: If the inverter overheats, it will shut down. Ensure proper ventilation and clear any obstructions from the fans.
  • Short Circuit Protection: In case of a short circuit, the inverter will protect itself by shutting down. Identify and resolve the short circuit before restarting.
  • High/Low Voltage Protection: The inverter will protect itself from abnormal input voltages. Check your battery and PV input voltages.
  • Cold Restart Function: The inverter has a cold restart function, allowing it to restart even in low-temperature conditions.

If the problem persists after checking these common issues, contact qualified service personnel.

Icons representing intelligent protection systems: Overload Protection, Overheating Protection, High Low Voltage protection, Battery Protection, Short Circuit Protection, Overcurrent Protection, Anti Reverse protection, Power Failure Protection.
Figure 10: The inverter features comprehensive 360° protection systems.

7. Specifications

The following table details the technical specifications of the Sumry HGX 4KW Hybrid Inverter:

CategoryParameterValue
ModelModel NumberHGX 4KW
Rated Power4000W
Size40*25*8.9cm
InputVoltage100/110/120VAC
Selectable Voltage Range90-140VAC
Frequency Range50Hz/60Hz (Autosensing)
OutputAC Voltage Regulation120VAC ±5%
Surge Power2* rated power for 5 seconds
Efficiency (Peak) PV to INV97%
Wave FormPure Sine Wave
Battery & AC ChargerBattery Voltage24VDC
Bulk Charging VoltageFlooded Battery: 29.2VDC, AGM/GEL Battery: 28.2VDC
Floating Charge Voltage27.6VDC
Overcharge Protection32VDC
Maximum Charge Current110A
Solar ChargerPV Input (DC)55-350VDC
Nominal DC Voltage/Maximum DC Voltage280VDC/350VDC
Start-up Voltage/Initial Feeding Voltage55VDC
MPPT Voltage Range55VDC-280VDC
Grid Output (AC)Nominal Output Voltage120Vac
Output Voltage Range95V-135V
Nominal Output Current33A
EfficiencyMaximum Conversion Efficiency (DC/AC)98%
MPPT Efficiency99.90%
PhysicalCommunication InterfaceCOMM port (Standard) LCD remote/WiFi (Optional)
Installation MethodAssembly

8. User Tips

  • Optimize Solar Panel Placement: Ensure your solar panels are positioned for maximum sun exposure throughout the day to achieve the highest MPPT efficiency.
  • Battery Management: Regularly check your battery's state of charge and avoid deep discharges to prolong battery life.
  • Ventilation is Key: Always ensure the inverter has ample space around it for airflow. Overheating can significantly reduce its lifespan and efficiency.
  • Monitor Display: Pay attention to the LCD display for any fault indicators or unusual readings, which can help in early detection of potential issues.
  • WiFi Monitoring: If you have the optional WiFi module, utilize the smart app for convenient remote monitoring and control of your system.

9. Warranty and Support

For warranty information and technical support, please refer to the official SUMRY website or contact your authorized dealer. Keep your purchase receipt as proof of purchase for any warranty claims.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.