1. Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Sumry 4KW Hybrid Inverter. Please read this manual thoroughly before installation and use, and keep it for future reference.
The Sumry 4KW Hybrid Inverter is an off-grid pure sine wave solar inverter designed for home use. It features a 140A MPPT solar charger, supports a maximum PV input of 5600W, and operates at 24V. It offers a 6.25-inch LCD display for easy monitoring and configuration.


2. Safety Information
Always follow basic safety precautions to reduce the risk of fire, electric shock, and injury to persons.
- Ensure proper grounding of the inverter.
- Do not disassemble the inverter. Refer servicing to qualified personnel.
- Keep the inverter away from flammable materials and moisture.
- Ensure adequate ventilation around the inverter to prevent overheating.
- Always disconnect all power sources (PV, utility, battery) before performing any maintenance or wiring.
3. Installation
3.1 Unboxing and Initial Inspection
Upon receiving your inverter, carefully unpack it and inspect for any shipping damage. Ensure all components are present as per the packing list.
3.2 Circuit Breaker Specifications
For the Sumry HGX 4KW inverter, specific circuit breakers are required for safety and optimal performance:
- Battery to Inverter: 2P200A circuit breaker.
- Photovoltaic (PV) Input to Inverter: 2P20A circuit breaker.
- Utility Input to Inverter: 2P63A circuit breaker.
- Inverter Output: 2P40A circuit breaker.

3.3 Wiring Steps
- Battery Connection: Install a 2P200A circuit breaker between the battery and the inverter. Ensure the circuit breaker is open. Connect the 24V battery to the inverter's battery terminals (positive to positive, negative to negative). Close the circuit breaker and measure the voltage on the inverter's battery side to confirm it's normal.
- PV Input Connection: Install a 2P20A circuit breaker between the PV input and the inverter. Ensure the circuit breaker is open. Connect the solar panels to the PV input terminals. Once the battery voltage is confirmed normal, close the PV input circuit breaker. The inverter display should light up and begin charging.
- AC Input and Output Connection: Install a 2P63A circuit breaker between the AC input (utility grid) and the inverter. Install a 2P40A circuit breaker between the inverter's output and your home appliances. Turn on both AC input and output circuit breakers. Connect the inverter to the mains. After 2 minutes, turn off the mains input circuit breaker, then turn off the inverter output circuit breaker. This completes the installation procedure.

3.4 Solar Panel Connection Guidelines
The Sumry HGX series inverter has a maximum PV charging power of 5600W and a PV charging voltage range of 55-350Vdc. When connecting solar panels, consider the voltage and power of individual panels to ensure they fall within the inverter's acceptable range.

4. Operation
4.1 Display and Controls
The inverter features a 6.25-inch LCD display and touchable buttons for user interaction. The display shows input/output voltage, battery status, load, and charging status.
4.2 Working Modes
The inverter offers versatile working modes to optimize power management:
- Charging Modes:
- Only Solar: Prioritizes solar power for charging.
- Solar First: Solar power is the primary charging source, supplemented by utility if needed.
- Mains & Solar: Both utility and solar power are used for charging.
- Output Modes:
- SBU (Solar-Battery-Utility): Prioritizes solar, then battery, then utility for powering loads.
- SUB (Solar-Utility-Battery): Prioritizes solar, then utility, then battery for powering loads.

4.3 Pure Sine Wave Output
The inverter provides a pure sine wave output, ensuring high compatibility with over 98% of electrical appliances, making it efficient and stable for sensitive electronics.

4.4 Battery Compatibility
The inverter is compatible with various 24V battery types, including Lithium, Gel, LiFePO4, Lead-acid, and AGM batteries. It also features built-in lithium battery automatic activation.

4.5 Monitoring and Communication
The inverter supports communication via RS232/RS485. An optional WiFi monitoring function is available, allowing you to monitor and control the system via a smart app. Note that only one communication method (WiFi module or battery BMS) can be used at a time. If using battery BMS, ensure it supports PACE or PYLONTECH protocols.

5. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter.
- Cleaning: Keep the inverter's ventilation openings clear of dust and debris. Use a dry cloth to clean the exterior.
- Connections: Periodically check all electrical connections for tightness and corrosion. Loose connections can cause overheating and damage.
- Battery Health: Monitor battery voltage and health regularly, especially if using lead-acid batteries.
- Environment: Ensure the inverter is installed in a dry, well-ventilated area, away from direct sunlight and extreme temperatures.
The inverter includes intelligent fans to enhance battery performance and reduce heat, contributing to system longevity.
6. Troubleshooting
The inverter is equipped with various protection features. If an issue occurs, the LCD display may show an error code or fault indicator.
- Overload Protection: If the load exceeds the inverter's capacity, it will shut down. Reduce the load and restart the inverter.
- Over-temperature Protection: If the inverter overheats, it will shut down. Ensure proper ventilation and clear any obstructions from the fans.
- Short Circuit Protection: In case of a short circuit, the inverter will protect itself by shutting down. Identify and resolve the short circuit before restarting.
- High/Low Voltage Protection: The inverter will protect itself from abnormal input voltages. Check your battery and PV input voltages.
- Cold Restart Function: The inverter has a cold restart function, allowing it to restart even in low-temperature conditions.
If the problem persists after checking these common issues, contact qualified service personnel.

7. Specifications
The following table details the technical specifications of the Sumry HGX 4KW Hybrid Inverter:
| Category | Parameter | Value |
|---|---|---|
| Model | Model Number | HGX 4KW |
| Rated Power | 4000W | |
| Size | 40*25*8.9cm | |
| Input | Voltage | 100/110/120VAC |
| Selectable Voltage Range | 90-140VAC | |
| Frequency Range | 50Hz/60Hz (Autosensing) | |
| Output | AC Voltage Regulation | 120VAC ±5% |
| Surge Power | 2* rated power for 5 seconds | |
| Efficiency (Peak) PV to INV | 97% | |
| Wave Form | Pure Sine Wave | |
| Battery & AC Charger | Battery Voltage | 24VDC |
| Bulk Charging Voltage | Flooded Battery: 29.2VDC, AGM/GEL Battery: 28.2VDC | |
| Floating Charge Voltage | 27.6VDC | |
| Overcharge Protection | 32VDC | |
| Maximum Charge Current | 110A | |
| Solar Charger | PV Input (DC) | 55-350VDC |
| Nominal DC Voltage/Maximum DC Voltage | 280VDC/350VDC | |
| Start-up Voltage/Initial Feeding Voltage | 55VDC | |
| MPPT Voltage Range | 55VDC-280VDC | |
| Grid Output (AC) | Nominal Output Voltage | 120Vac |
| Output Voltage Range | 95V-135V | |
| Nominal Output Current | 33A | |
| Efficiency | Maximum Conversion Efficiency (DC/AC) | 98% |
| MPPT Efficiency | 99.90% | |
| Physical | Communication Interface | COMM port (Standard) LCD remote/WiFi (Optional) |
| Installation Method | Assembly |
8. User Tips
- Optimize Solar Panel Placement: Ensure your solar panels are positioned for maximum sun exposure throughout the day to achieve the highest MPPT efficiency.
- Battery Management: Regularly check your battery's state of charge and avoid deep discharges to prolong battery life.
- Ventilation is Key: Always ensure the inverter has ample space around it for airflow. Overheating can significantly reduce its lifespan and efficiency.
- Monitor Display: Pay attention to the LCD display for any fault indicators or unusual readings, which can help in early detection of potential issues.
- WiFi Monitoring: If you have the optional WiFi module, utilize the smart app for convenient remote monitoring and control of your system.
9. Warranty and Support
For warranty information and technical support, please refer to the official SUMRY website or contact your authorized dealer. Keep your purchase receipt as proof of purchase for any warranty claims.