1. Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Sumry 4KW 120V Off Grid Solar Inverter. Please read this manual thoroughly before installation and use, and keep it for future reference.
The Sumry HGX series inverter is a hybrid off-grid solar inverter designed to provide uninterruptible power support for various household and office loads. It integrates the functions of an inverter, solar charger, and battery charger, featuring a 6.25-inch LCD display with touchable buttons for user-friendly configuration.
2. Key Features
- Off-grid solar inverter with 4000W power output and 120VAC.
- No battery function available (can run loads directly from PV array without battery).
- SBU mode: Utility power, battery, and PV power complement each other.
- Pure sine wave output for high compatibility with various appliances.
- Unique glass top cover design with a 6.25-inch LCD display and touchable buttons.
- Built-in 140A MPPT solar charger (Max PV 5600W).
- High PV input voltage range from 55V-350Vdc.
- Smart battery charger design for optimized battery performance.
- Configurable AC/Battery input priority via LCD setting.
- Auto restart while PV is recovering.
- Comprehensive protection: Overload, over-temperature, and output short circuit protection.
- Cold restart function.
- Built-in lithium battery automatic activation.
- Communication with RS232/RS485.
- WiFi monitoring function (optional).
- Anti-dust kit for harsh environments (optional).
- Restore default settings with one click.
3. Safety Information
WARNING: Electrical equipment should only be installed, operated, serviced, and maintained by qualified personnel. Improper installation or use may cause serious injury, death, or equipment damage.
- Ensure all wiring is performed by a qualified electrician and complies with local and national electrical codes.
- Always disconnect all power sources (PV, battery, AC input) before performing any maintenance or wiring.
- Do not attempt to open or repair the inverter yourself. Refer to qualified service personnel.
- Ensure proper ventilation around the inverter to prevent overheating.
- Keep children away from the inverter.
- Use appropriate circuit breakers as specified in the installation section.
4. Specifications
The following table details the technical specifications for the Sumry HGX (110V) 4KW model:
| Attribute | Value |
|---|---|
| Model Number | HGX 4KW |
| Size | 40*25*8.9cm |
| Frame Material | Metal |
| Installation Method | Assembly |
| Origin | Mainland China |
| Feature | Hybrid inverter |
| Feature 2 | solar inverters |
| Feature 3 | hybrid solar inverter |
| Feature 4 | Pure sine wave inverter |
| Feature 5 | mppt solar charge controller |
| Support Battery type | lithium battery, LiFePo4, acid-lead, etc. |
| AC output voltage | 110-120VAC -50Hz/60Hz |
| Wave form | Pure Sine Wave |
| Battery voltage | 24VDC |
| BMS communication | YES |
5. Installation
Proper installation is crucial for the safe and efficient operation of your inverter. Please follow these steps carefully.
5.1 Connection Ports Overview
5.2 Installation Steps
-
Battery Connection: Install a circuit breaker between the battery and the inverter. After successful installation, connect the 24V battery. Close the circuit breaker and measure the voltage on the battery side of the inverter to ensure it is normal.
-
PV Input Connection: Install a circuit breaker between the PV input and the inverter. Turn on this circuit breaker after successful installation. Ensure the battery voltage is normal. Connect the solar energy to the inverter, then close the circuit breaker between the PV input and the inverter. The inverter display will automatically light up and start charging. Press the button on the bottom right corner of the inverter to start the machine. Verify that there is 110V or 120V voltage output from the inverter.
-
AC Input and Output Connection: Install a circuit breaker between the AC input and the inverter. Also, install a circuit breaker between the output of the inverter and your home appliances. After successful installation, turn on the circuit breakers for both AC input and output. Connect the machine to the mains. After 2 minutes, turn off the mains input circuit breaker, and then turn off the circuit breaker of the inverter's output. This completes the installation procedure.
5.3 Circuit Breaker Specifications
For the Sumry HGX 4000W inverter, the following circuit breaker specifications are recommended:
- Between Battery and Inverter: 2P200A circuit breaker.
- Between Photovoltaic Input and Inverter: 2P20A circuit breaker.
- Between Utility Input and Inverter: 2P63A circuit breaker.
- On the Inverter Output: 2P40A circuit breaker.
5.4 System Wiring Diagram
Before installing and using the inverter, it is recommended to install 4 circuit breakers in the following positions:
- Between the battery pack and the inverter battery input.
- Between the solar panel and the photovoltaic input of the inverter.
- Between the power input of the grid and the inverter.
- Between inverter output and load.
The circuit breaker effectively prevents misconnection or reverse connection of the mains input and the inverter output. In case of a short circuit, load short circuit, or overload in the output, the circuit breaker can directly cut off the circuit to protect the inverter.
5.5 Solar Photovoltaic Panel Wiring Method
The maximum PV charging power for the SUMRY HGX series is 5600W, with a PV charging voltage range of 55-350V. When connecting solar panels, consider both series and parallel configurations to meet voltage and current requirements without exceeding the inverter's maximum input limits.
In Series: Increases the voltage of the system. The total voltage must be less than the hybrid inverter's maximum input voltage (Voc/inverter). Example: 6 panels (41.92V/10.35A each) in series result in 251.52V and 10.35A.
In Parallel: Increases the current of the system. The total current should not exceed the maximum PV input current of the hybrid inverter. Example: 3 sets of 2 panels (41.92V/10.35A each) in parallel result in 125.76V and 20.7A.
PV cable dimensions: 6-8A/mm².
5.6 Overall System Diagram
6. Operation
6.1 Pure Sine Wave Output
The Sumry inverter produces a pure sine wave output, ensuring high compatibility with over 98% of electrical appliances. This provides stable and safe power, similar to grid electricity, unlike modified sine wave inverters which can cause issues with sensitive electronics.
6.2 Versatile Working Modes
The inverter offers flexible power management with configurable input and output priorities:
- Charging Modes:
- Only Solar
- Solar First
- Mains & Solar
- Output Modes:
- SBU (Solar-Battery-Utility)
- SUB (Solar-Utility-Battery)
6.3 Battery Compatibility
The Sumry inverter is compatible with a wide range of 24V batteries, including:
- Flooded (FLD)
- Gel
- Lithium-ion phosphate (LiFePO4)
- Lithium-ion
- AGM/Sealed (SLD)
- User-customizable battery types
6.4 Monitoring and Communication
The inverter supports various communication methods for monitoring and control:
- RS232/RS485: Standard communication ports are available.
- WiFi Monitoring (Optional): An optional WiFi module can be connected to the COMM port for remote monitoring and control via a smartphone app. Note that only one communication method (WiFi or battery BMS) can be used at a time.
- Battery BMS Communication: If using battery BMS for communication, ensure the battery supports PACE or PYLONTECH communication protocols.
7. Protection Features
The Sumry inverter charger incorporates intelligent protection systems to ensure 360° safety and system longevity:
- Overload Protection: Prevents damage from excessive load.
- Overheating Protection: Shuts down the unit if internal temperatures become too high.
- High/Low Voltage Protection: Safeguards against input voltage fluctuations.
- Battery Protection: Protects the battery from overcharge and deep discharge.
- Short Circuit Protection: Automatically disconnects in case of a short circuit.
- Overcurrent Protection: Prevents damage from excessive current draw.
- Anti-Reverse Protection: Protects against incorrect polarity connections.
- Power Failure Protection: Ensures stable operation during power interruptions.
8. Maintenance
Regular maintenance helps ensure the longevity and optimal performance of your inverter:
- Cleaning: Periodically clean the exterior of the inverter with a dry cloth. Ensure ventilation openings are free from dust and debris.
- Connection Checks: Regularly inspect all electrical connections (battery, PV, AC input/output) to ensure they are tight and free from corrosion.
- Environment: Ensure the inverter is installed in a cool, dry, and well-ventilated area, away from direct sunlight, moisture, and flammable materials.
- Battery Health: If using batteries, monitor their health and charge levels according to the battery manufacturer's recommendations.
9. Troubleshooting
If you encounter issues with your Sumry inverter, consider the following basic troubleshooting steps:
- No Power Output: Check all circuit breakers (battery, PV, AC input/output) to ensure they are in the ON position. Verify battery voltage and PV input voltage are within the specified ranges.
- Inverter Not Charging: Ensure solar panels are connected correctly and receiving sufficient sunlight. Check PV input voltage. Verify battery connections.
- Error Codes: Refer to the inverter's LCD display for any error codes. Consult the full product manual (if available) for specific error code interpretations.
- Overload Warning: Reduce the connected load. The inverter will typically attempt to restart automatically after an overload event.
- Over-temperature Warning: Ensure adequate ventilation around the inverter. Clear any obstructions from cooling vents.
For persistent issues or complex problems, contact qualified technical support.
10. User Tips
- Optimal PV Sizing: When connecting solar panels, carefully calculate the total voltage and current for both series and parallel configurations to stay within the inverter's maximum input limits (5600W max PV, 55-350Vdc range). Using a PV array that is too large or too small can reduce efficiency or damage the unit.
- Battery Management: Utilize the smart battery charger design and configurable AC/Battery input priority settings via the LCD to optimize battery performance and lifespan, especially for different battery chemistries like LiFePO4 or lead-acid.
- Remote Monitoring: If opting for the WiFi module, ensure it is correctly installed and configured with the app to monitor system performance and settings remotely, which can help in proactive maintenance and troubleshooting.
- Environmental Considerations: While the inverter has an optional anti-dust kit, regularly check the installation environment for excessive dust or moisture, which can impact performance and longevity.
11. Warranty and Support
The Sumry 4KW 120V Off Grid Solar Inverter typically comes with a 1-year warranty. For warranty claims, technical support, or service inquiries, please contact your original point of purchase or the manufacturer's authorized service center. Ensure you have your product model number and purchase details available.