1. Introduction
The JIKONG Smart Active Balance Battery Management System (BMS) is a sophisticated management solution designed for large capacity series lithium battery packs. It integrates essential functions such as precise voltage and current acquisition, active current balancing, and comprehensive protection mechanisms including overcharge, over-discharge, overcurrent, and over-temperature. Additionally, it features coulomb metering and Bluetooth communication for enhanced monitoring and control.
This BMS is highly versatile, supporting a wide range of battery chemistries including LiFePO4, Ternary Lithium, Lithium Titanate, and Sodium batteries.
At its core, the system utilizes energy transfer active balancing technology with independent intellectual property rights. This technology ensures optimal battery consistency, significantly extends battery life, and delays aging by efficiently transferring energy from higher voltage cells to lower voltage cells with minimal energy loss. It achieves a maximum continuous balance current of 0.6A.
A dedicated mobile application (APP) is available for both Android and iOS operating systems. This APP allows users to connect to the BMS via Bluetooth to monitor real-time battery status, modify protection parameters, and control charge/discharge switches, providing a user-friendly interface for managing the battery system.
With its compact size, ease of operation, and comprehensive functionality, the JIKONG Smart Active Balance BMS is widely applicable in various scenarios, including small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage systems, base station backup power supplies, and solar power stations.


2. Specifications
The JIKONG Smart Active Balance BMS is available in two primary models: JK-BD6A24S4PD (40A) and JK-BD6A24S6PD (60A). Detailed specifications are provided below.
2.1. Model Variants and Features
The BMS offers various functions and configurations:
- Active Equalizing Current: 0.6A (Standard for both models)
- Bluetooth Function: Standard
- UART Serial Communication: Optional
- NTC Quantity: 1 built-in, 1 external, with an option for 2 external configurations
- One-wire Communication: Optional
- LED Battery Level Display: Optional
- Protection Functions (Standard): Charging overvoltage, charging overcurrent, discharge undervoltage, discharge overcurrent, and short circuit protection.


2.2. Battery Adaptation Guide
The BMS supports various battery types and string configurations:
- Ternary Lithium Battery: 7-24S (for 40A models), 7-20S (for 60A models)
- Lithium Iron Battery (LiFePO4): 8-24S (for 40A models), 8-20S (for 60A models)
- Lithium Titanate Battery (LTO): 14-24S (for 40A models), 14-20S (for 60A models)
2.3. General Parameters
| Parameter | Value (40A Model) | Value (60A Model) | Unit |
|---|---|---|---|
| Supply Voltage | 20-100 | 20-100 | V |
| Operating Power Consumption | <800 | <800 | mW |
| Operating Temperature | -30-70 | -30-70 | °C |
| Max Number of Collection Strings | 24 | 24 | Strings |
| Max Balancing Current | 0.6 | 0.6 | A |
| Max Charging Current | 40 | 60 | A |
| Max Discharge Current | 40 | 60 | A |
| Max Instantaneous Current | 80 | 120 | A |
| Max Internal Loop Resistance | 1.6 | 1.1 | mΩ |
| Protective Plate Size | 116.8*94.8*14.6 | 116.8*94.8*14.6 | mm |
| Finished Weight | 325 | 327 | g |
Note: The data tolerance range is ±2mm for dimensions.
2.4. Default Parameters
The following table outlines the default parameters for various battery chemistries. These values can be adjusted via the mobile APP to suit specific battery requirements.
| Parameter | Li-Ion Default | LiFePO4 Default | LTO Default | Unit |
|---|---|---|---|---|
| Balancing Initial Voltage | 3 | 3 | 2 | V |
| Maximum Balancing Current | 0.6 | 0.6 | 0.6 | A |
| Unit Overcharge Voltage | 4.2 | 3.6 | 2.7 | V |
| Single Overcharge Protection Recovery | 4.18 | 3.55 | 2.65 | V |
| Monomer Undervoltage Protection | 2.82 | 2.6 | 1.8 | V |
| Single Undervoltage Protection Recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic Shutdown Voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% Voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% Voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger Balancing Differential Pressure | 0.01 | 0.01 | 0.01 | V |
| Charging Overcurrent Protection Delay | 30 | 30 | 30 | S |
| Charge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Discharge Overcurrent Protection Delay | 300 | 300 | 300 | S |
| Discharge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Short-circuit Protection Delay | 5 | 5 | 5 | µS |
| Charging Overtemperature Protection | 70 | 70 | 70 | °C |
| Charge Overtemperature Restore Temperature | 60 | 60 | 60 | °C |
| Discharge Overtemperature Protection | 70 | 70 | 70 | °C |
| Discharge Overtemperature Recovery | 60 | 60 | 60 | °C |
| Charging Low Temperature Protection | -20 | -20 | -20 | °C |
| Charge Low Temperature Restore Temperature | -10 | -10 | -10 | °C |
| MOS Overtemperature Protection | 100 | 100 | 100 | °C |
| MOS Overtemperature Recovery | 80 | 80 | 80 | °C |
| Device Address | 0 | 0 | 0 | / |
2.5. Physical Dimensions
The JK-BD6A24S-4PD series protection board measures 116.8mm x 94.8mm x 14.6mm. For specific model dimensions, refer to the figures below:


3. Package Contents
Please verify that all items are present in the package:
- BMS x 1
- Sampling line x 1 (70cm long)
- NTC (Temperature Sensor) x 1 (40cm long)
- Switch x 1 (50cm long)

4. Installation and Wiring
The JK-BD6A24S-4PD series protection board is suitable for 7-24 series lithium battery packs. The specific wiring method depends on the number of cells in your battery pack. Always ensure proper safety precautions when working with battery systems.
4.1. General Installation Steps
- Connect all balance cables to the corresponding ports on the BMS.
- Insert the main power cables (B- line and P- line) into the designated terminals on the BMS.
- Connect the B- line and the P- line to the battery pack's negative and positive terminals, respectively.
Important Safety Note:
- Before powering on the protection board, meticulously double-check that all balance cables are correctly connected to their respective cell taps and that the main power connections (P- and B-) are accurate.
- Verify that the protection board is securely fixed to the battery pack to prevent movement or damage.
- Incorrect connections can lead to abnormal operation, severe damage to the device, or pose safety risks.
4.2. Wiring Diagrams
Refer to the following diagrams for typical wiring configurations based on the number of battery strings:


4.3. Interface Definition
The BMS features various interfaces for communication, sensing, and control. Understanding these connections is crucial for proper installation and operation.

The protection board comes standard with UART serial communication. Optional one-wire communication is also available. Users can configure the device address and communication protocol according to their specific requirements and application scenarios.
Connector P1 (HY2.0-15P) - Balance and Acquisition Interface:
- Pin 1: B- (Total negative battery)
- Pin 2-23: B1-B23 (Positive terminals of individual battery cells, B1 for cell 1, B2 for cell 2, etc.)
- Pin 24: B+ (Total battery positive)
Connector P3 (HY2.0-2P) - Temperature Interface:
- Pin 1: TA (Temperature sensor pin A)
- Pin 2: TB (Temperature sensor pin B)
Optional P3 (HY2.0-4P) - External Temperature Interface (2 sets):
- Pin 1: T1A (First temperature sensor pin A)
- Pin 2: T1B (First temperature sensor pin B)
- Pin 3: T2A (Second temperature sensor pin A)
- Pin 4: T2B (Second temperature sensor pin B)
Connector P4 (1.25T-6PWT) - One-wire Interface:
- Pin 1: GNDT (One-wire negative pole)
- Pin 2: TX (One-Wire signal)
- Pin 3-6: Test interface
Connector P5 (FPC06-Q0.5-9AH2.0) - Light Panel Interface:
- Pin 1: K+ (Activate the positive signal)
- Pin 2: K- (Activation signal negative electrode)
- Pin 3: LED- (Light panel signal negative electrode)
- Pin 4-9: LEDIR, LED1G, LED2, LED3, LED4, LED5 (Light panel signal positive electrode)
Bluetooth Connection Indicator (D1):
- Steady on: Bluetooth connected to the protection board.
- Blinking: Connection disconnected.
P- Terminal: Connects to external load or negative terminal of charger.
B- Terminal: Connects to the negative battery terminal.
5. Operation
5.1. Device Activation
The JIKONG BMS does not feature a physical power-on switch. It is designed for activation via charging. After the battery assembly is fully completed and all connections are verified, connect the charger to the battery pack. The charger voltage must be at least 2V higher than the battery voltage for the BMS to activate and begin operation.
Alternatively, if you have opted for the optional light panel, you can activate the BMS by simply inserting its cable into the light panel interface and pressing the activation button on the panel.
5.2. Mobile APP Usage
The JIKONG BMS offers intelligent interaction and easy operation through its dedicated mobile application, available for Android and iOS devices.
- APP Installation: To download the mobile APP, scan the QR code provided below. Please note that Android Version 7 or higher is required for compatibility.

Figure 11: Mobile APP Link QR Code. Scan this code with your smartphone to download the JIKONG BMS application. - Parameter Setting: The APP allows you to freely adjust multiple protection values, including overcharge, over-discharge, overcurrent, and temperature limits. Before making any changes, it is crucial to carefully review the internal parameters of the protection board to ensure safe and appropriate settings for your battery pack.
- Monitoring: The APP provides a comprehensive multi-screen display for data connection, offering a clear overview of critical battery information at a glance. You can monitor parameters such as individual cell voltages, total current, temperature, State of Charge (SOC), active alarms, and cycle count.

Figure 12: Multi-screen Display and Data Connection. The mobile phone Bluetooth APP "JIKONG SMART BMS" provides a clear overview of battery information including Voltage, Current, Temperature, SOC, Alarms, and Cycles. The APP supports iOS/Android/HarmonyOS and multiple languages. Users can also choose between mobile APP, PC software, or a dedicated JIKONG home storage display.
5.3. LED Battery Level Display (Optional)
If your BMS is equipped with the optional LED power level display, the following table indicates the approximate battery charge level based on the illuminated LEDs:
| SOC | LED1 | LED2 | LED3 | LED4 | LED5 |
|---|---|---|---|---|---|
| 0%-9% | ● | ○ | ○ | ○ | ○ |
| 10%-19% | ● | ● | ○ | ○ | ○ |
| 20%-39% | ● | ● | ● | ○ | ○ |
| 40%-59% | ● | ● | ● | ● | ○ |
| 60%-79% | ● | ● | ● | ● | ● |
| 80%-100% | ● | ● | ● | ● | ● |
Legend: ● = Green (always on), ○ = Off
6. Protection Features
The JIKONG BMS is equipped with comprehensive protection functions to ensure the safety and longevity of your battery pack. Most parameters are user-configurable via the mobile APP, allowing for tailored protection settings.
- Charge Overvoltage Protection & Recovery: The BMS will automatically cease charging if the voltage of any individual cell exceeds the user-defined overvoltage protection limit. Charging will resume once all cell voltages drop below the set recovery voltage, preventing overcharging and potential cell damage.
- Discharge Undervoltage Protection & Recovery: Should the voltage of any cell fall below the configured undervoltage protection limit during discharge, the BMS will cut off the discharge path to protect the cells from deep discharge. Discharge will resume when all cell voltages rise above the recovery voltage. An additional automatic shutdown voltage can be configured for critical low-voltage scenarios.
- Charge Overcurrent Protection & Recovery: If the charging current surpasses the set continuous charging current for a specified delay period, the BMS will halt charging. Charging will automatically resume after the configured overcurrent release time.
- Discharge Overcurrent Protection & Recovery: If the discharge current exceeds the set continuous discharge current for a specified delay, the BMS will cut off the discharge. Discharge will resume after the overcurrent release time. Note that the maximum continuous discharge current cannot exceed 40A for the JK-BD6A24S4PD model or 60A for the JK-BD6A24S6PD model.
- Overtemperature Protection & Recovery: The BMS continuously monitors the temperature of the battery pack. If temperatures exceed the user-defined overtemperature limits for charging or discharging, the BMS will stop the respective operation. Operation will resume once temperatures fall back within the safe recovery ranges.
- Low Temperature Protection & Recovery: The BMS will prevent charging if temperatures drop below the set low temperature protection limit. Charging will resume once temperatures rise above the configured low temperature recovery threshold.
- Short Circuit Protection & Recovery: The BMS provides robust short circuit protection. While the trigger current is fixed, users can configure the short circuit protection delay and recovery time via the APP. This feature is crucial for preventing damage from instantaneous high currents that can occur during initial connection or load startup.
- Emergency Switch: In critical situations, such as persistent over-temperature, over-discharge, over-charge, or cell string issues, activating the emergency switch via the APP will force the BMS to maintain charge/discharge functionality for a 30-minute period. This provides a temporary operational window to safely manage your battery system or reach a safe location.
- Intelligent Sleep: This feature allows the BMS to enter a low-power standby mode if the charge/discharge current remains below 1A for 26 consecutive hours. This reduces the BMS's self-consumption from the battery. The BMS can be reactivated by pressing a button (if equipped with a light panel) or by connecting a charger.
7. Maintenance
To ensure optimal performance, reliability, and longevity of your JIKONG Smart Active Balance BMS, adhere to the following maintenance guidelines:
- Regular Monitoring: Periodically check the battery parameters and BMS status using the mobile APP. Consistent monitoring helps in the early detection of any anomalies or potential issues, allowing for timely intervention.
- Connection Integrity: Regularly inspect all wiring connections, particularly the balance cables and main power connections, to ensure they remain secure and free from corrosion. Loose or corroded connections can lead to inaccurate readings, reduced performance, or system malfunctions.
- Environmental Conditions: Always operate the BMS within its specified operating temperature range (-30°C to 70°C). Extreme temperatures can stress the electronic components and affect the BMS's performance and lifespan.
- Firmware Updates: Check the official JIKONG website or APP for any available firmware updates for the BMS and the mobile application. Keeping your software up-to-date ensures you have the latest features, performance enhancements, and bug fixes.
- Physical Inspection: Occasionally perform a visual inspection of the BMS unit for any signs of physical damage, discoloration due to overheating, or unusual odors. The aluminum alloy shell is designed for durability and efficient heat dissipation, but external factors can still cause wear.
- Cleaning: Keep the BMS unit clean and free from dust, dirt, and moisture. Use a soft, dry cloth for cleaning. Avoid using harsh chemicals or abrasive materials.
8. Troubleshooting
If you encounter issues with your JIKONG Smart Active Balance BMS, refer to the following common troubleshooting steps. For persistent problems, consult the detailed documentation or contact technical support.
- BMS Not Activating:
- Ensure all balance cables and main power connections (P- and B-) are correctly and securely wired according to the installation diagrams.
- Verify that the charger voltage is at least 2V higher than the battery voltage for proper charging activation.
- If using an optional light panel, confirm it is connected and the activation button is pressed.
- Protection Triggered (e.g., Overvoltage, Undervoltage, Overcurrent, Overtemperature):
- Check the specific alarm or protection status displayed on the mobile APP.
- Review the parameter settings in the APP to ensure they are appropriate for your battery type and application. Incorrect settings can lead to premature protection triggers.
- Allow the battery to recover to within safe operating parameters (e.g., temperature to drop, voltage to normalize).
- For short circuit protection, if it triggers frequently during load startup, consider increasing the short circuit protection delay in the APP, as some loads have high instantaneous current draw.
- Bluetooth Connection Issues:
- Ensure the BMS is powered on and operational.
- Verify that Bluetooth is enabled on your mobile device and that you are within range.
- Check the D1 indicator on the BMS: if it's blinking, the connection is disconnected; if steady, it's connected. Try reconnecting through the APP.
- Ensure your mobile APP is updated to the latest version.
- Inaccurate Readings:
- Inspect all balance cable connections for looseness, damage, or corrosion, which can lead to inaccurate cell voltage readings.
- Ensure the NTC temperature sensors are properly installed and making good thermal contact with the battery cells.
- If necessary, perform voltage and current calibration via the APP, following the instructions in the parameter setting guide.
If the problem persists after following these steps, please consult the detailed "Instructions for Setting Protection Board Parameters" document or contact JIKONG technical support for further assistance.
9. User Tips
Leveraging the full potential of your JIKONG Smart Active Balance BMS can enhance battery performance and longevity. Here are some user tips:
- Initial Setup Vigilance: Always double-check all wiring connections, especially the balance leads and main power connections, before the very first power-up. This critical step prevents potential damage and ensures correct operation from the start.
- Parameter Customization: Take full advantage of the mobile APP's parameter setting capabilities. Fine-tune the BMS settings to precisely match your specific battery chemistry (Li-Ion, LiFePO4, LTO) and the demands of your application. This optimization can significantly improve efficiency and protection.
- Proactive Balancing: While the BMS provides active balancing, for optimal battery longevity and performance, strive to maintain a balanced state by avoiding consistent deep discharges or overcharges of individual cells. The 0.6A active balancing current is effective but may require time for severely unbalanced packs.
- Consistent Monitoring: Make it a habit to regularly use the mobile APP to monitor individual cell voltages, temperatures, and overall battery health. This proactive approach allows you to identify potential issues early, before they escalate into critical problems.
- Emergency Function Familiarity: Familiarize yourself with the emergency switch function. In a critical situation, knowing how to activate it can provide a temporary operational window to safely manage your battery system or reach a safe location.
Note: Specific user tips would typically be derived from common feedback and questions if available from user reviews or Q&A data.
10. Warranty and Support
For warranty information, technical support, or service inquiries regarding your JIKONG Smart Active Balance BMS, please contact JIKONG Factory Store directly. Refer to your purchase documentation for specific warranty terms and conditions applicable to your product.
You can also refer to the official JIKONG website (WWW.JK-BMS.COM) for additional resources, updated documentation, and frequently asked questions.
A comprehensive user manual in PDF format is available for download, which contains detailed information on product specifications, installation, operation, and troubleshooting: