1. Introduction
The KKMOON WEL3005 Electronic Load Module is a multifunctional device designed for various electrical testing applications, including power aging tests and battery discharge. It features a clear color display, adjustable constant current, and robust protection mechanisms to ensure safe and accurate operation.

2. Features
- Clear color display for easy reading of parameters.
- Multiple protection functions: Undervoltage Protection (1.5-30V), Over Power Protection (1-30W), Overheat Protection (fan starts at >45°C, protection at 75°C).
- High power and high accuracy with continuously adjustable current (0A-5A).
- Input anti-reverse protection.
- Suitable for decoration and construction, hydropower engineering, power aging tests, and battery discharge.
3. Specifications
| Parameter | Value |
|---|---|
| Model | WEL3005 |
| Module Supply Voltage | 6V-30V |
| Measuring Voltage | 0-30V |
| Discharge Current | 0A-5A (Continuously Adjustable) |
| Discharge Power | Up to 30W (Do not exceed) |
| Working Temperature | -10°C to +75°C |
| Voltage Resolution | 0.01V |
| Current Resolution | 0.001A |
| Voltage Accuracy | 1% ± 1 digit |
| Current Accuracy | 1% ± 1 digit |
| Undervoltage Protection | Yes (1.5-30V adjustable) |
| Over Power Protection | Yes (1-30W adjustable) |
| Overheat Protection | Yes (Fan starts >45°C, protection at 75°C) |
| Input Anti-Reverse | Yes |
| Fan | 4010 Double Roller Fan, Speed 8000 RPM |
| Module Size | Approx. 79 x 43 x 70mm / 3.1 x 1.7 x 2.8in |
| Hole Opening Size | Approx. 76 x 39mm / 3 x 1.5in |
4. Setup and Wiring
Before operating the module, ensure proper wiring and installation.
- Mounting: The module is designed for panel mounting. Create a hole with dimensions approximately 76 x 39mm (3 x 1.5in) for installation.
- Power Supply: Connect a power supply within the 6V-30V range to the module's supply terminals.
- Load Connection:
- For measuring voltage, connect the small screen printing B+ and B- terminals.
- For measuring current, connect the large screen printing B+ and B- terminals.
- Cooling: Ensure adequate space around the module, especially for the cooling fan, to prevent overheating.


5. Operating Instructions
The module features a color display and several controls for operation.

- Power On/Off: The rotary knob also functions as an on/off key. Rotate it to adjust data and press it to confirm selections.
- Navigation:
- P1/P2 Buttons: Use P1 and P2 buttons to switch between different interfaces or presets.
- SET Button: Press the SET button to enter the setting menu.
- Adjusting Parameters:
- In the setting menu, use the rotary knob to navigate through options and adjust values (e.g., discharge current, undervoltage protection, overpower protection).
- Press the rotary knob to confirm your selection.
- Lock Function: Press the "LOCK" button to prevent accidental changes to settings during operation.
- Display Information: The color screen provides real-time readings for:
- Voltage (U)
- Current (I)
- Power (P)
- Ampere-hours (Ah)
- Watt-hours (Wh)
- Internal Resistance (R)
- Temperature (T)

6. Maintenance
- Cleaning: Keep the module clean and free from dust. Use a soft, dry cloth for cleaning.
- Cooling Fan: The integrated 4010 double roller fan (8000 RPM) activates when the temperature exceeds 45°C to maintain optimal operating conditions. Ensure the fan is not obstructed.
- Storage: Store the module in a dry, cool environment when not in use.
7. Troubleshooting
The WEL3005 module includes several built-in protections to prevent damage.
- Undervoltage Protection: If the input voltage drops below the set undervoltage protection limit (adjustable from 1.5-30V), the module will cease discharge to protect the power source.
- Over Power Protection: If the discharge power exceeds the set limit (adjustable from 1-30W), the module will stop operation. Ensure the total discharge power does not exceed 30W.
- Overheat Protection: If the internal temperature reaches 75°C, the module will automatically shut down to prevent damage. Ensure proper ventilation and cooling.
- Input Anti-Reverse: The module is protected against reverse polarity connection of the input power supply.
- No Display/No Function: Check the module supply voltage (6V-30V) and all wiring connections.
Important: Do not exceed the maximum discharge power of 30W to prevent damage to the module.
8. User Tips
- When mounting the module, ensure you leave plenty of space for cooling, especially around the fan, to maintain efficient operation and prevent overheating.
- This compact electronic load module is particularly well-suited for battery testing applications due to its adjustable constant current and clear display.
- Despite its small size, the module is effective and provides accurate readings for its intended use.
9. Warranty and Support
For any technical assistance, warranty claims, or support inquiries, please contact the seller or manufacturer directly. Keep your purchase records for reference.