1. Introduction
The OWON HDS200 Series is a versatile 3-in-1 handheld device combining a digital oscilloscope, a digital multimeter, and a waveform generator (available on 'S' models). Designed for both professional and outdoor use, it features a high-resolution color LCD, long battery life, and PC software connectivity. This manual provides essential information for the safe and effective operation of your device.

Figure 1: OWON HDS200 Series Handheld Oscilloscope
2. Key Features
- 3-in-1 Functionality: Oscilloscope, Multimeter, and Waveform Generator (Waveform Generator only with 'S' models).
- Display: 3.5-inch high-resolution, high-contrast color LCD.
- Battery Life: Can work continuously for approximately 6 hours on a 18650 lithium battery.
- Power Management: USB Type-C interface supports charging via adapter or power bank.
- Connectivity: Supports PC software connection for data analysis and control.
- Self-Calibration: Built-in self-calibration function for accuracy.
- SCPI Support: Facilitates secondary development and automation.
- Compact Design: Small size (198mm x 96mm x 38mm) and lightweight (approx. 0.6 kg without battery) for portability.
- Hangable Bracket: Integrated bracket for convenient placement, saving working space.

Figure 2: Overview of Oscilloscope, Multimeter, and Waveform Generator functions
3. Package Contents
Verify that all items are present and in good condition upon unpacking:
- OWON HDS200 Series Device
- Power Cord
- Oscilloscope Probe(s)
- Quick Guide
- USB Type-C Cable
- Multimeter Test Leads
- Probe Adjustment Tool
- Soft Bag
- BNC Plug to Alligator Clips Cable (for waveform generator output)

Figure 3: Included accessories
4. Setup
4.1 Powering On and Charging
The device is powered by a 18650 lithium battery. Before first use, ensure the battery is charged. Connect the device to a power source using the provided USB Type-C cable. The USB Type-C interface supports charging via an adapter or a power bank. The device can operate continuously for approximately 6 hours on a full charge.

Figure 4: Power management and USB Type-C interface
4.2 Initial Connections
Identify the input and output ports on your device:
- Oscilloscope Input: BNC connectors for oscilloscope probes.
- Multimeter Input Connectors: Standard banana plug inputs for multimeter test leads (VΩ+C, COM, mA, A).
- Waveform Generator Output: BNC connector for waveform generator output (on 'S' models).
Ensure all connections are secure before operation. The plastic shell design of the BNC connector enhances safety during testing.

Figure 5: Device dimensions and port locations
4.3 PC Software Connection
The USB Type-C interface also supports connection to PC software. This allows for viewing, analyzing, and sharing waveform data. Connect the device to your computer using the USB Type-C cable. The computer should recognize the oscilloscope as a USB flash drive, allowing access to CSV waveform files.
4.4 Self-Calibration
The device includes a self-calibration function to maintain accuracy. Refer to the on-screen menu or quick guide for instructions on initiating self-calibration.
5. Operating Instructions
5.1 General Operation
The HDS200 Series features a 3.5-inch color LCD for clear display of waveform data and measurements. Navigate through modes and settings using the control buttons on the front panel.
5.2 Oscilloscope Mode
The oscilloscope function allows for detailed waveform analysis. Key features include:
- Acquisition Modes: Sample, Peak Detect. Peak detect is useful for reducing jamming blur and improving clarity.
- Waveform Refresh Rate: Up to 10,000 wfrms/s for capturing infrequent events.
- Record Length: 8K for detailed waveform capture.
- Input Coupling: DC, AC, Ground options.
- Probe Attenuation: Settings from 1X to 10000X.
- Triggering: Edge trigger type with Auto, Normal, and Single trigger models. Trigger level range is ±4 divisions from the screen center.
- Measurements: Automatic measurements for Period, Frequency, Mean, PK-PK, Max, Min, Amplitude. Cursor measurement function for ΔV, ΔT, and ΔT&ΔV between cursors.
- Save Function: Save up to 4 settings, 4 reference waveforms, and 4 CSV waveform files.

Figure 6: Oscilloscope performance features
5.3 Multimeter Mode
The digital multimeter provides precise measurements with 20,000 counts and True RMS. Testing modes include:
- Voltage (DC and AC)
- Current (DC and AC)
- Resistance (Ω)
- Capacitance (F)
- Diode Test (0-2V)
- Continuity Test
Maximum input voltage is AC 750V and DC 1000V. Maximum input current is 10A for both DC and AC.
5.4 Waveform Generator Mode (HDS242S, HDS272S, HDS2102S, HDS2202S only)
For 'S' models, the built-in waveform generator offers various output types:
- Frequency Output: Sine (0.1Hz-25MHz), Square (0.1Hz-5MHz), Ramp (0.1Hz-1MHz), Pulse (0.1Hz-5MHz), Arbitrary Waveform (0.1Hz-5MHz).
- Sample Rate: 125MSa/s.
- Amplitude: 20mVpp-5Vpp (high impedance), 10mVpp-2.5Vpp (50Ω).
- Waveform Length: 8K.
- Vertical Resolution: 14 bits.
- Load Impedance: 50Ω.

Figure 7: Waveform Generator functions
6. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
- Battery Care: For optimal battery life, avoid extreme temperatures and store the device with a partial charge if not used for extended periods.
- Storage: Store the device in a cool, dry place, away from direct sunlight and corrosive environments.
- Probe Care: Handle probes carefully. Damaged probes can affect measurement accuracy and user safety.
7. Troubleshooting
If you encounter issues with your OWON HDS200 Series device, consider the following basic troubleshooting steps:
- No Power: Ensure the battery is charged or the device is connected to a power source via the USB Type-C cable.
- No Signal/Incorrect Reading (Oscilloscope/Multimeter): Check all cable connections, ensure probes are correctly attached and not damaged. Verify input coupling and probe attenuation settings.
- Display Issues: Restart the device. If the issue persists, contact support.
- PC Connection Problems: Ensure the USB Type-C cable is properly connected and the PC software is correctly installed.
For more complex issues, please refer to the official OWON support resources or contact your seller.
8. Specifications
8.1 Oscilloscope Specifications
| Parameter | HDS242 | HDS272 | HDS2102 | HDS2202 | HDS242S | HDS272S | HDS2102S | HDS2202S |
|---|---|---|---|---|---|---|---|---|
| Bandwidth | 40MHz | 70MHz | 100MHz | 200MHz | 40MHz | 70MHz | 100MHz | 200MHz |
| Channel | 2 | 2+1 (Signal Generator) | ||||||
| Sample Rate | 250MSa/s | 500MSa/s | 1GSa/s | 250MSa/s | 500MSa/s | 1GSa/s | ||
| Acquisition Model | Sample, Peak Detect | |||||||
| Record Length | 8K | |||||||
| Display | 3.5 inch LCD | |||||||
| Waveform Refresh Rate | 10000 wfrms/s | |||||||
| Input Coupling | DC, AC, Ground | |||||||
| Input Impedance | 1 MΩ±2%, in parallel with 16 pF±10 pF | |||||||
| Probe Attenuation | 1X, 10X, 100X, 1000X, 10000X | |||||||
| Max. Input Voltage | 400V (DC+AC, PK - PK) | |||||||
| Bandwidth Limit (typical) | 20MHz / Full bandwidth | |||||||
| Sampling Rate Range | 5ns/div~500s/div, step by 1 – 2 - 5 | 2ns/div~1000s/div, step by 1 – 2 - 5 | 5ns/div~500s/div, step by 1 – 2 - 5 | 2ns/div~1000s/div, step by 1 – 2 - 5 | ||||
| Sensitivity Resolution | 10mV/div~10V/div | |||||||
| Low Frequency (-3db) | ≥10 Hz (at input, AC coupling) | |||||||
| Rise Time (at input, Typical) | ≤8ns | ≤5ns | ≤3.5ns | ≤1.75ns | ≤8ns | ≤5ns | ≤3.5ns | ≤1.75ns |
| Trigger Type | Edge | |||||||
| Trigger Model | Auto, Normal, Single | |||||||
| Trigger Level Range | ±4 div from the screen center | |||||||
| Automatic Measurement | Period, Frequency, Mean, PK-PK, Max, Min, Amplitude | |||||||
| Cursor Measurement | ΔV, ΔT, ΔT&ΔV between cursors, Auto Cursor | |||||||
| Communication Interface | USB Type-C | |||||||
8.2 Digital Multimeter Specifications
| Parameter | Value |
|---|---|
| Full Scale Reading | 4 Digits (max 20000 count) |
| Testing Modes | Voltage, Current, Resistance, Capacitance, Diode, Continuity |
| Maximum Input Voltage | AC 750V, DC 1000V |
| Maximum Input Current | DC: 10A, AC: 10A |
| Diodes Test | 0-2V |
| Frequency Response (Hz) | (40 - 1000) Hz |
Multimeter Measurement Range and Accuracy
| Measurement Type | Measurement Range | Accuracy |
|---|---|---|
| DC Voltage | 200.00mV | ±(0.3%+10 dig) |
| 2.0000V/20.000V/200.00V | ±(0.3%+5 dig) | |
| 1000.0V | ||
| AC Voltage | 200.00mV/2.0000V/20.000V/200.00V | ±(0.8%+10dig) |
| 750.00V | ±(1%+10dig) | |
| DC Current | 200.00mA | ±(0.8%+10dig) |
| 10.000A | ±(2.5%+10dig) | |
| AC Current | 200.00mA | ±(1%+10dig) |
| 10.000A | ±(2.8%+10dig) | |
| Resistance (Ω) | 200.00Ω/2.0000kΩ/20.000kΩ/200.00kΩ/2.0000MΩ | ±(0.8%+10dig) |
| 20.000MΩ | ±(1%+3dig) | |
| 100.00MΩ | ±(5%+10dig) | |
| Capacitance (F) | 20.000nF/200.00nF/2.0000μF/20.000μF/200.00μF/2.0000mF | ±(3.0%+10dig) |
8.3 Signal Generator Specifications (HDS242S, HDS272S, HDS2102S, HDS2202S only)
| Parameter | Type | Value |
|---|---|---|
| Frequency Output | Sine | 0.1Hz~25MHz |
| Square | 0.1Hz~5MHz | |
| Ramp | 0.1Hz~1MHz | |
| Pulse | 0.1Hz~5MHz | |
| Arbitrary Waveform | 0.1Hz~5MHz | |
| Sample Rate | 125MSa/s | |
| Channel | 1 | |
| Amplitude | 20mVpp-5Vpp (high impedance), 10mVpp-2.5Vpp (50Ω) | |
| Waveform Length | 8K | |
| Vertical Resolution | 14 bits | |
| Load Impedance | 50Ω | |
8.4 Physical Specifications
- Dimensions: 198mm (Height) x 96mm (Width) x 38mm (Depth)
- Weight: Approximately 0.6 kg (main device, without battery)
9. Warranty and Support
For warranty information, please refer to the documentation provided at the time of purchase or contact your authorized OWON dealer. For technical support, troubleshooting assistance, or service inquiries, please reach out to the seller or OWON customer service through their official channels. Keep your purchase receipt or order details handy for any warranty claims.
10. User Tips
- Maximize Portability: Utilize the hangable bracket to position the device conveniently in various work environments, saving bench space.
- Efficient Charging: Take advantage of the USB Type-C charging and power bank compatibility for extended outdoor use.
- Data Management: Regularly connect to PC software via USB Type-C to save and analyze your waveform data, especially for critical measurements.
- Leverage 3-in-1: For 'S' models, remember to switch between oscilloscope, multimeter, and waveform generator modes to fully utilize the device's comprehensive capabilities for different testing scenarios.
- Current Measurement: If your model supports it, use the added current measurement function with a current probe for more convenient and accurate readings.

Figure 8: Device with hangable bracket