1. Introduction
This manual provides comprehensive instructions for the assembly, installation, operation, and troubleshooting of your Sumry Off Grid Hybrid Solar Inverter. Please read this manual carefully before proceeding with installation or operation, and keep it for future reference.
1.1 Product Features
- Pure sine wave inverter for clean and stable power output.
- Programmable supply priority for PV, battery, or grid.
- High PV input voltage range (55-450VDC).
- Built-in Max 110A (3.8KW & 6.2KW) MPPT solar charger.
- Compatible with various battery types, including Lithium-ion, Gel, LifePO4, Lead-acid, and AGM.
- Supports BMS communication with Lithium batteries.
- Smart battery charge design for optimized battery life.
- Comprehensive protections: Overload, high temperature, inverter output short circuit.
- Cold start function.
- Intelligent fan speed adjustment for efficient heat dissipation.
- Optional built-in anti-dust kit for harsh environments.
- WiFi & GPRS available for iOS and Android monitoring (optional).
1.2 Basic System Architecture
The inverter/charger combines the functions of an inverter, solar charger, and battery charger to provide uninterrupted power. It can operate with solar power, battery, and utility grid inputs to supply power to connected loads.

2. Safety Instructions
⚠ WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION: To reduce the risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION: Only qualified personnel can install this device with a battery.
- Never charge a frozen battery.
- For optimum operation, follow required specifications to select appropriate cable sizes.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts, which could cause an explosion.
- Strictly follow installation procedures when disconnecting AC or DC terminals.
- GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Comply with local requirements and regulations.
- Never cause AC output and DC input short circuits. Do not connect to the mains when DC input short circuits.
- WARNING: Only qualified service persons are able to service this device. If errors still persist after following troubleshooting, send this inverter/charger back to a local dealer or service center.
3. Setup and Installation
3.1 Unpacking and Inspection
Before installation, carefully inspect the unit. Ensure no damage occurred during transit. The package should contain the inverter unit and this user manual.
3.2 Mounting the Unit
Select a mounting location that is a solid surface and not made of flammable materials. Install the inverter at eye level for easy LCD display reading. Ensure adequate air circulation with at least 20 cm clearance on the sides and 50 cm above and below for heat dissipation. The optimal ambient temperature for operation is between 0°C and 55°C. Mount the unit vertically using M4 or M5 screws.

3.3 Connection Steps
Before connecting any wires, remove the bottom cover by unscrewing the two retaining screws.
- Battery Connection:
Install a circuit breaker between the battery and the inverter. After successful installation, open the breaker. Connect the battery, ensuring correct polarity (positive to positive, negative to negative). Close the circuit breaker. Measure the voltage on the battery side of the inverter to confirm proper connection.
Recommended battery cable sizes:
Model Wire Size Cable (mm²) Torque value (max) 2.2KVA 12V 1 x 4AWG 22 2 Nm 3.2KVA 24V 1 x 6AWG 14 2 Nm ⚠ WARNING: Installation must be performed with care due to high battery voltage in series.
⚠ CAUTION: Before closing the DC breaker/disconnector, ensure positive (+) is connected to positive (+) and negative (-) to negative (-).
- PV Input Connection:
Install a DC circuit breaker between the PV input and the inverter. Turn on the circuit breaker after successful installation. Ensure battery voltage is normal. Connect the solar panels to the inverter. Close the circuit breaker between the PV input and the inverter. The inverter display should light up and begin charging automatically.
Recommended PV cable sizes:
Model Wire Size Torque value (max) 2.2KVA 12V 1 x 16AWG 1.2 Nm 3.2KVA 24V 1 x 6AWG 1.2 Nm PV Module Selection Considerations:
- Open circuit voltage (Voc) of PV modules must not exceed the maximum PV array open circuit voltage of the inverter (450VDC).
- PV Array MPPT Voltage Range: 90VDC~430VDC.

Solar photovoltaic panel wiring methods for series and parallel connections. Ensure the entire system uses the same type of panel. PV cable dimensions: 6-8A/mm². - AC Input/Output Connection:
Install a separate AC breaker between the inverter and the AC input power source. This ensures the inverter can be securely disconnected during maintenance and is protected from overcurrent. The recommended AC breaker is 20A for 2.2KVA models and 32A for 3.2KVA models.
Install a circuit breaker between the output of the machine and the inverter. Turn on the AC input and output circuit breakers. Connect the machine to the mains. Turn off the mains input circuit breaker, then turn off the inverter output circuit breaker after 2 minutes. This is the complete procedure for installing the machine.
Recommended AC wire sizes:
Model Gauge Torque Value 2.2KVA 12V 14 AWG 0.5~0.6Nm 3.2KVA 24V 12 AWG 1.2 Nm ⚠ WARNING: All wiring must be performed by qualified personnel. Do not mis-connect input and output connectors.

Wiring diagram illustrating connections for AC input, AC output, battery, and PV input, including recommended circuit breaker placements. Circuit Breaker Specifications:
Inverter Power Battery Breaker PV Input Breaker Utility Input Breaker Output Breaker 3KW 2P100A 2P10A 2P32A 2P15A 3.8KW 2P150A 2P20A 2P40A 2P20A 6.2KW 2P150A 2P20A 2P63A 2P30A 
Detailed circuit breaker specifications for different inverter power models.
3.4 Final Assembly
After all wirings are connected and verified, replace the bottom cover and secure it with the four screws.
4. Operation
4.1 Power ON/OFF
Once the unit is properly installed and batteries are connected, press the On/Off switch (located on the bottom of the case) to turn on the unit.
4.2 Operation and Display Panel
The front panel of the inverter features an LCD display, three indicators, and four function keys for operation and monitoring.

LED Indicators
| LED Indicator | Messages |
|---|---|
| AC / INV (Green Solid On) | Output is powered by utility in Line mode. |
| AC / INV (Green Flashing) | Output is powered by battery or PV in battery mode. |
| CHG (Green Solid On) | Battery is fully charged. |
| CHG (Green Flashing) | Battery is charging. |
| FAULT (Red Solid On) | Fault occurs in the inverter. |
| FAULT (Red Flashing) | Warning condition occurs in the inverter. |
Function Keys
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
4.3 LCD Display Icons
The LCD displays various information about the inverter's status. Key icons include:
- AC Icon: Indicates AC input.
- PV Icon: Indicates PV input.
- INPUTBATT: Displays input voltage, frequency, PV voltage, charger current, charger power, and battery voltage.
- OUTPUTBATTLOAD: Displays output voltage, frequency, load percentage, load in VA, load in Watt, and discharging current.
- CHARGING: Indicates battery level (0-24%, 25-49%, 50-74%, 75-100%) and charging status.
- OVERLOAD: Indicates an overload condition.
- Mains Connection Icon: Unit connects to the mains.
- PV Panel Connection Icon: Unit connects to the PV panel.
- BYPASS: Load is supplied by utility power.
- Utility Charger Icon: Utility charger circuit is working.
- DC/AC Inverter Icon: DC/AC inverter circuit is working.
- Mute Icon: Unit alarm is disabled.
4.4 Operating Modes
The inverter offers versatile working modes to customize power input and output priorities:
- Line Mode: The unit provides output power from the mains and charges the battery.
- Battery Mode: The unit provides output power from the battery and PV power.
- Charging Modes:
- Only Solar: Battery is charged only by solar power.
- Solar First: Solar energy charges the battery first; utility charges if solar is unavailable.
- Mains & Solar: Both mains and solar charge the battery simultaneously.
- Output Modes:
- Solar First: Solar energy powers loads first. If solar is insufficient, utility supplies power.
- SBU First (Solar-Battery-Utility): Solar energy powers loads first, then battery, then utility if both are insufficient or battery voltage is low.
- Standby/Power Saving Mode: In this mode, the inverter output will be off if the connected load is very low or not detected, saving power. The unit can still charge batteries.

4.5 Battery Equalization
Battery equalization is a function designed to reverse the buildup of negative chemical effects like stratification and sulfation, which can reduce battery capacity. It is recommended to equalize batteries periodically.
To apply equalization:
- Enable battery equalization in LCD setting program 33.
- Ensure program 5 is set to "User-Defined" or "Flooded" mode.
- Set equalization parameters in programs 34 to 37 according to your battery requirements.
- Equalization can be activated immediately via program 39.
5. Maintenance
5.1 Anti-Dust Kit Clearance and Maintenance (Optional)
The inverter comes with an anti-dust kit installed from the factory. This kit helps prevent dust ingress and improves product reliability. The inverter automatically detects the kit and adjusts internal thermal sensors.
- Remove the screws securing the dustproof case.
- Carefully remove the dustproof case and take out the air filter foam.
- Clean the air filter foam and dustproof case.
- After cleaning, re-assemble the dust-kit back onto the inverter.
NOTE: The anti-dust kit should be cleaned from dust every one month.
6. Troubleshooting
Refer to the table below for common problems, their possible causes, and recommended solutions.
| Problem | LCD/LED/Buzzer Indication | Explanation / Possible Cause | What to Do |
|---|---|---|---|
| Unit shuts down automatically during startup process. | LCD/LEDs and buzzer active for 3 seconds, then off. | Battery voltage is too low (<1.91V/cell). | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | No indication. | 1. Battery voltage is too low (<1.4V/cell). 2. Internal fuse tripped. | 1. Contact repair center for replacing fuse. 2. Re-charge battery. 3. Replace battery. |
| Mains exist but unit works in battery mode. | Input voltage displayed on LCD, green LED flashing. | Input protector is tripped. | Check if AC breaker is tripped and AC wiring is connected well. |
| Green LED is flashing. | Insufficient quality of AC Power (shore or Generator). | 1. Check if AC wires are too thin and/or too long. 2. Check if generator (if applied) is working well or if input voltage range setting is correct (UPS/Appliance). | |
| Unit turned on, internal relay switches on and off repeatedly. | LCD display and LEDs are flashing. | Battery is disconnected. | Check if battery wires are connected well. |
| Buzzer beeps continuously and red LED is on. | Fault code 07 | Overload error. The inverter is overloaded 110% and time is up. | Reduce the connected load by switching off some equipment. |
| Fault code 05 | Output short circuited. | Check if wiring is connected well and remove abnormal load. | |
| Fault code 02 | Temperature of internal converter component is over 120°C. / Internal temperature of inverter component is over 100°C. | Check whether the airflow of the unit is blocked or whether the ambient temperature is too high. | |
| Fault code 03 | Battery is over-charged. / The battery voltage is too high. | Return to repair center. / Check if spec and quantity of batteries are meet requirements. | |
| Fault code 01 | Fan fault. | Replace the fan. | |
| Fault code 06/58 | Output abnormal (Inverter voltage below 190VAC or higher than 260VAC). | 1. Reduce the connected load. 2. Return to repair center. | |
| Fault code 08/09/53/57 | Internal components failed. | Return to repair center. | |
| Fault code 51 | Over current or surge. | Restart the unit. If the error happens again, please return to repair center. | |
| Fault code 52 | Bus voltage is too low. | Restart the unit. If the error happens again, please return to repair center. | |
| Fault code 55 | Output voltage is unbalanced. | Restart the unit. If the error happens again, please return to repair center. |
Warning Indicators
| Warning Code | Warning Event | Audible Alarm |
|---|---|---|
| 01 | Fan is locked when inverter is on. | Beep three times every second. |
| 03 | Battery is over-charged. | Beep once every second. |
| 04 | Low battery. | Beep once every second. |
| 07 | Overload. | Beep once every 0.5 second. |
| 10 | Output power derating. | Beep twice every 3 seconds. |
7. Specifications
The Sumry SP series hybrid solar inverter is available in various power ratings. Below are detailed specifications for different models.

7.1 Product Data Sheet

7.2 Line Mode Specifications
| Parameter | 2.2KVA-12V | 3.2KVA-24V |
|---|---|---|
| Input voltage waveform | Sinusoidal (utility or generator) | |
| Nominal Input voltage | 230VAC | |
| LOW Loss voltage | 170VAC±7V (UPS); 90VAC±7V (Appliances) | 170VAC±7V (UPS); 90VAC±7V (Appliances) |
| LOW LOSS Return voltage | 180VAC±7V (UPS); 100VAC±7V (Appliances) | 180VAC±7V (UPS); 100VAC±7V (Appliance) |
| High Loss voltage | 280VAC±7V | |
| High LOSS Return voltage | 270VAC±7V | |
| Max AC Input voltage | 300VAC | |
| Nominal Input Frequency | 50HZ / 60HZ (Auto detection) | |
| LOW LOSS Frequency | 40±1HZ | |
| LOW LOSS Return Frequency | 42±1HZ | |
| High LOSS Frequency | 65±1HZ | |
| High LOSS Return Frequency | 63±1HZ | |
| Output Short Circuit Protection | Circuit Breaker | |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) | |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) | |
7.3 Inverter Mode Specifications
| Parameter | 2.2KVA-12V | 3.2KVA-24V |
|---|---|---|
| Rated output power | 2200VA/1800W | 3200VA/3000W |
| Output voltage waveform | Pure sine wave | |
| Output voltage Regulation | 230VAC±5% | |
| Output Frequency | 50Hz | |
| Peak Efficiency | 94% | |
| Overload protection | 5s@ ≥150% load; 10s@ 110% - 150% load | |
| Surge capacity | 2* rated power for 5 seconds | |
| Nominal DC Input voltage | 12VDC | 24VDC |
| Cold start voltage | 11.5VDC | 23.0VDC |
| Low DC warning voltage (@load < 50%) | 11.0VDC | 22.0VDC |
| Low DC warning voltage (@load ≥ 50%) | 10.5VDC | 21.0VDC |
| Low DC warning Return voltage (@load < 50%) | 11.5VDC | 22.5VDC |
| Low DC warning Return voltage (@load ≥ 50%) | 11.0VDC | 22.0VDC |
| Low DC Cut-off voltage (@load < 50%) | 10.2VDC | 20.5VDC |
| Low DC Cut-off voltage (@load ≥ 50%) | 9.6VDC | 20.0VDC |
| High DC Recovery voltage | 14.5VDC | 29VDC |
| High DC cut-off voltage | 15.5VDC | 31VDC |
| No Load power consumption | <25W | <35W |
7.4 Charge Mode Specifications
| Parameter | 2.2KVA-12V | 3.2KVA-24V |
|---|---|---|
| Charging Algorithm | 3-step | |
| AC Charging current (Max) | 60Amp (@VRP=230VAC) | 60Amp (@VRP=230VAC) |
| Bulk charging voltage (Flooded Battery) | 14.6V | 29.2V |
| Bulk charging voltage (AGM / Gel Battery) | 14.1V | 28.2V |
| Floating charging voltage | 13.5VDC | 27VDC |
| Max. PV Array power | 2000W | 3000W |
| Nominal PV voltage | 240VDC | |
| PV Array MPPT voltage Range | 90~430VDC | |
| Max. PV Array open circuit voltage | 450VDC | |
| Max charging current (AC Charger plus solar charger) | 80Amp | |
7.5 General Specifications
| Parameter | 2.2KVA-12V | 3.2KVA-24V |
|---|---|---|
| Safety certification | CE | |
| Operating Temperature Range | -10°C to 50°C | |
| Storage Temperature | -15°C to 60°C | |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
| Dimension (D*W*H), mm | 348*282*105mm | |
| Net weight, kg | 5.0 | 5.5 |
8. User Tips
- Battery Compatibility: Ensure your battery type is correctly selected in the inverter settings for optimal charging and discharge performance. The inverter supports various battery chemistries, so proper configuration is crucial.
- Monitoring: Utilize the optional WiFi module and mobile app to monitor your system's performance remotely. This allows for real-time tracking of power generation, consumption, and battery status.
- Load Management: Be mindful of your total connected load to avoid overloading the inverter. Refer to the specifications for maximum load capacities and consider staggering the startup of high-power appliances.
- Ventilation: Always ensure the inverter has adequate ventilation as specified in the installation section. Proper airflow is essential for heat dissipation and prolonging the lifespan of the unit.
- Grounding: Always ensure the inverter is properly grounded to prevent electrical hazards and ensure safe operation.
9. Warranty and Support
The product comes with a 1-year warranty. For any technical support, troubleshooting assistance beyond this manual, or warranty claims, please contact your local dealer or the Sumry service center. Refer to the official user manual PDF for detailed warranty terms and conditions: User manual (PDF).
10. Product Overview Video
Watch this video for a visual guide on the Sumry Hybrid Solar Inverter, including unboxing, connections, and demonstration of its features.