Hantek Hantek 6074BC/6104BC/6204BC/6254BC

Contents

Hantek PC USB Oscilloscope Series User Manual

Models: 6074BC, 6104BC, 6204BC, 6254BC

1. Introduction

The Hantek PC USB Oscilloscope series (models 6074BC, 6104BC, 6204BC, 6254BC) offers a powerful and portable solution for waveform analysis. Designed to connect to your personal computer via a USB 2.0 interface, these devices transform your PC into a versatile 4-channel digital oscilloscope. With real-time sampling rates up to 1GSa/s and bandwidths ranging from 70MHz to 250MHz, they provide performance comparable to traditional benchtop oscilloscopes in a compact, easy-to-carry form factor. The anodized aluminum casing ensures durability and heat resistance, making it suitable for various applications from laboratory work to field diagnostics.

2. Key Features

  • 4 Independent Analog Channels: Simultaneous measurement and analysis of multiple signals.
  • High Performance: Up to 1GSa/s real-time sampling rate and 250MHz bandwidth (model dependent).
  • Wide Input Sensitivity: 2mV-10V/DIV for capturing a broad range of signal amplitudes.
  • USB 2.0 Interface: Plug-and-play connectivity with your PC for easy setup and portability.
  • Advanced Trigger Functions: Supports Edge, Pulse, Video, and Alternative trigger modes for precise signal capture.
  • Waveform Analysis: Includes Pass/Fail test, dynamic cursor tracking, waveform record and replay, and FFT spectrum analyzer.
  • Comprehensive Measurement: Over 20 automatic measurement functions (e.g., Vpp, Vmax, Frequency, Duty Cycle).
  • Data Export: Waveform data can be exported to EXCEL, BMP, and JPG formats.
  • Software Compatibility: Supports Windows 7, Windows 8, and Windows 10 operating systems.
  • Durable Design: Anodized aluminum casing provides excellent heat and abrasive resistance.
  • Expandable: One computer can connect with multiple oscilloscopes to expand channel count.
  • Development Support: Provides secondary development library DLL and examples for Labview, VB, VC, QT.

3. Package Contents

Verify that all items listed below are included in your package:

  • 1 x Hantek PC USB Oscilloscope Unit
  • 2 x Oscilloscope Probes
  • 2 x BNC - Clip Cables
  • 1 x USB Cable
  • 1 x Software CD
Hantek PC USB Oscilloscope and included accessories
Image 1: Hantek PC USB Oscilloscope with probes, BNC-clip cables, and USB cable.

4. Specifications

ParameterValue
ModelHantek6074BC/Hantek6104BC/Hantek6204BC/Hantek6254BC
Bandwidth70MHz/100MHz/200MHz/250MHz
Channel4 CH
Real-time Sampling Rate1GSa/s
Memory Depth64K
Time Base Precision±50ppm
Time Base Range2ns/div-1000s/div (1-2-4 sequences)
Input Impedance1MΩ 25pF
Input Sensitivity2mV/div~10V/div
Vertical Resolution8Bit
Vertical Displacement Range2mV ~ 10V/div @ x1 probe; 20mV ~ 100V/div @ x10 probe; 200mV ~ 1000V/div @ x100 probe; 2V ~ 10000V/div @ x1000 probe
DC Gain Accuracy±3%
Bandwidth Limit20MHz
Trigger ModeEdge, Pulse, Video, Alternative
Trigger SourceCH1, CH2, CH3, CH4
Waveform Signal Process+,-,x,÷,FFT, Invert
Cursors MeasurementCross, Trace, Horizontal, Vertical
Auto MeasurementVpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg, Vrms, Vcrms, Preshoot, Overshoot, Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle
Volume175mm x 105mm x 25mm
Weight0.9KG
Accessory2 passive probes, 2 gator clip lines

5. Setup Guide

5.1. Hardware Connection

  1. Connect to PC: Use the provided USB cable to connect the Hantek oscilloscope to an available USB 2.0 port on your computer.
  2. Connect Probes: Attach the oscilloscope probes to the BNC input connectors (CH1, CH2, CH3, CH4) on the side of the Hantek unit. Ensure a secure connection.
  3. Connect BNC-Clip Cables: For specific measurements requiring direct connection or grounding, use the BNC-clip cables. Connect the BNC end to an available channel and the clip end to your test point or ground.
Hantek Oscilloscope USBXI and BNC interfaces
Image 2: Rear and front view of the Hantek oscilloscope showing the USBXI Interface, USB Interface, and CH1-CH4 Trigger Sources (BNC inputs).

5.2. Software Installation

  1. Insert Software CD: Place the included software CD into your computer's CD/DVD drive.
  2. Run Installer: Navigate to the CD drive and run the setup executable (e.g., setup.exe). Follow the on-screen instructions to install the Hantek oscilloscope software.
  3. Download (Optional): If you do not have a CD drive or prefer the latest version, download the software from the official Hantek website.
  4. System Requirements: Ensure your PC runs Windows 7, Windows 8, or Windows 10 for optimal compatibility.

6. Operating Instructions

6.1. Basic Operation

  1. Launch Software: After installation, launch the Hantek oscilloscope application from your desktop or Start Menu.
  2. Select Channels: In the software interface, enable or disable the desired channels (CH1-CH4) for your measurement.
  3. Adjust Scales: Use the vertical (Volts/Div) and horizontal (Time/Div) controls to adjust the waveform display to your requirements.
  4. Configure Trigger: Set the trigger mode (Edge, Pulse, Video, Alternative), trigger source (CH1-CH4), and trigger level to stabilize the waveform.
  5. Perform Measurements: Utilize the automatic measurement functions to quickly obtain parameters like Vpp, Frequency, Duty Cycle, etc.
  6. Waveform Processing: Apply functions like FFT for frequency domain analysis, or mathematical operations (+,-,x,÷) between channels.

6.2. Automotive Diagnostics Example (Ignition Test)

The Hantek oscilloscope can be used for various automotive diagnostics, such as testing ignition systems. The following steps demonstrate a typical setup for an ignition test:

  1. Prepare Engine: Ensure the vehicle engine is accessible and safe to work on.
  2. Connect Oscilloscope: Connect the Hantek unit to your laptop via USB.
  3. Connect Probe to Ignition Coil: Carefully attach an oscilloscope probe to the ignition coil of a spark plug. This typically involves removing the spark plug boot and inserting the probe.
  4. Ground Connection: Connect the ground clip of the probe or a BNC-clip cable to a suitable ground point on the engine chassis.
  5. Start Engine: Start the vehicle engine.
  6. Observe Waveform: On your laptop, observe the ignition waveform displayed by the Hantek software. Analyze the waveform for any anomalies that might indicate ignition system issues.
Video 1: Demonstration of Hantek oscilloscope connected to a car engine for ignition system diagnostics, showing probe connection and waveform display on a laptop.

7. Maintenance

  • Cleaning: Keep the oscilloscope unit and probes clean and free from dust and debris. Use a soft, dry cloth for cleaning. For stubborn dirt, a slightly damp cloth with mild detergent can be used, ensuring no liquid enters the device.
  • Storage: Store the oscilloscope in a cool, dry place away from direct sunlight, extreme temperatures, and high humidity. Use the original packaging or a protective case to prevent physical damage.
  • Probe Care: Handle probes and cables with care. Avoid bending cables sharply or applying excessive force to connectors. Inspect probes regularly for any signs of wear or damage.
  • Software Updates: Periodically check the Hantek official website for software updates to ensure you have the latest features and bug fixes.

8. Troubleshooting

  • No Waveform Display:
    • Check if the USB cable is securely connected to both the oscilloscope and the PC.
    • Verify that the Hantek software is correctly installed and running.
    • Ensure probes are properly connected to the BNC inputs and the signal source.
    • Confirm that the selected channel in the software is enabled.
  • No Trigger/Unstable Waveform:
    • Adjust the trigger level in the software. The trigger level should be within the amplitude range of your signal.
    • Check the trigger mode (e.g., Edge, Pulse) and ensure it matches your signal characteristics.
    • Verify the trigger source is set to the correct channel.
  • Noisy or Distorted Waveform:
    • Ensure proper grounding of the oscilloscope and the circuit under test.
    • Perform probe compensation if necessary (refer to probe manual).
    • Minimize external electromagnetic interference by keeping the setup away from strong electrical fields.
  • Software Not Recognizing Device:
    • Reinstall the device drivers from the provided CD or Hantek website.
    • Try connecting to a different USB port on your PC.
    • Restart your computer.

9. User Tips

  • Probe Compensation: For accurate measurements, especially at higher frequencies, ensure your probes are properly compensated. This usually involves connecting the probe to a calibration signal (often available on the oscilloscope itself or a dedicated calibrator) and adjusting the probe's compensation trimmer until a perfect square wave is displayed.
  • Grounding is Key: Always ensure a solid ground connection between the oscilloscope, the probe, and the circuit under test. Poor grounding can lead to noisy measurements and inaccurate readings.
  • Utilize Software Features: Explore all the features offered by the Hantek software, such as FFT for frequency analysis, waveform math, and automatic measurements. These tools can significantly enhance your diagnostic capabilities.
  • Start with Auto-Set: If you're unsure about initial settings, use the 'Auto-Set' function (if available in the software) to get a quick, stable display of your signal. You can then fine-tune the settings manually.

10. Warranty and Support

For detailed warranty information and technical support, please refer to the official Hantek website or contact their customer service directly. Keep your purchase receipt as proof of purchase for any warranty claims.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.