1. Introduction
This manual provides instructions for the safe and effective use of your Mitutoyo Digital Thickness Gauge. These high-precision instruments are designed for accurately measuring the thickness of various materials, including small components, paper, and felt. The gauges feature a robust design with an integrated bezel and dial to prevent ingress of water or oil, ensuring durability and consistent performance.
Mitutoyo offers a range of models within the 7-547 series, each tailored for specific measurement needs. Please refer to the specifications section for details on individual models.

2. Safety Information
Please read and understand all safety instructions before operating the thickness gauge. Failure to follow these instructions may result in injury or damage to the instrument.
- Always handle the gauge with care to avoid dropping or impacting the precision components.
- Do not attempt to disassemble or modify the instrument, as this may void the warranty and affect accuracy.
- Keep the gauge away from strong magnetic fields, excessive heat, and direct sunlight.
- Ensure the measuring surfaces are clean before use to maintain accuracy.
- When not in use, store the gauge in its protective case.
3. Product Components
A typical Mitutoyo Digital Thickness Gauge consists of the following main components:
- Digital Display: Shows measurement readings.
- Measuring Probe/Spindle: The movable part that contacts the workpiece.
- Anvil: The stationary part against which the workpiece is pressed.
- Frame: The main body of the gauge.
- Operating Buttons: (MODE, SET, DATA, ON/OFF, ZERO/SET, PRESET/ABS) for controlling functions and settings.
- Lifting Lever: Used to raise the measuring probe.


4. Specifications
The Mitutoyo Digital Thickness Gauges are available in several models with varying specifications. Below is a summary of common features and detailed tables for specific models.
General Specifications:
- Brand Name: Mitutoyo
- Display Type: Digital
- DIY Supplies: Metalworking
- Origin: Japan (Jp)
- High-concerned chemical: None
- Certification: None
Model-Specific Performance Parameters (Digital Display Type):

This table provides an overview of various digital thickness gauge models, their measurement capabilities, and key characteristics.
| Measurement Range (mm) | Item Number | Resolution | Accuracy | Measuring Force | Remarks |
|---|---|---|---|---|---|
| 0 - 12mm | 547-401 | 0.001mm | ±3µm | Below 3.5N | High-precision type, carbide mandrel/anvil |
| 0 - 10mm | 547-301 | 0.01mm | ±20µm | Below 1.5N | Standard type, ceramic mandrel/measuring anvil |
| 0 - 10mm | 547-321 | 0.01mm | ±20µm | Below 1.5N | Deep reach type, ceramic mandrel/anvil |
| 0 - 10mm | 547-313 | 0.01mm | ±20µm | Below 1.5N | Lens thickness measurement |
| 0 - 10mm | 547-315 | 0.01mm | ±20µm | Below 1.5N | Groove depth wall thickness |
| 0 - 10mm | 547-360 | 0.01mm | ±20µm | Below 1.5N | Pipe fitting thickness measurement |
*Note: Imperial metric types (e.g., 547-400S, 547-300S) are also available with corresponding resolutions and accuracies.
Detailed Specifications for 'A' Models:

This table provides more granular details for specific 'A' series models, including measuring head and anvil types, parallelism, and mass.
| Item Number | Resolution/Graduation Value (mm) | Measuring Range (mm) | Measuring Depth (mm) | Measuring Head and Anvil | Parallelism between Probe and Anvil (µm) | Indication Error (µm) | Force Measurement (N) | Mass (g) |
|---|---|---|---|---|---|---|---|---|
| 547-401A | 0.0005 (0.001/0.01 switchable) | 0 - 12 | 21 | Ø6.3 plane (carbide) | Below 3 | ±3 | Below 3.5 | 280 |
| 547-301A | 0.01 | 0 - 10 | 30 | Ø10 plane | Below 10 | ±20 | Below 1.5 | 255 |
| 547-321A | 0.01 | 0 - 10 | 120 | Ø10 plane | Below 10 | ±20 | Below 1.5 | 425 |
Note: After replacing the probe, the indicator also needs to be adjusted. For custom orders, please contact Sanfeng company.
7-547 Series Thickness Gauge for Narrow Slots:

| Item Number | Resolution/Graduation Value (mm) | Measuring Range (mm) | Measuring Head and Anvil Dimensions (width x thickness) | Parallelism between Probe and Anvil (µm) | Indication Error (µm) | Force Measurement (N) | Mass (g) |
|---|---|---|---|---|---|---|---|
| 547-315A | 0.01 | 0 - 10 | 6.5 x 1 | Below 10 | ±20 | Below 1.5 | 270 |
| 7315A | 0.01 | 0 - 10 | 6.5 x 1 | 5 | ±15 | 1.4 or less | 220 |
Note 1: Only guaranteed in the width direction. Note 2: After replacing the probe, the indicator also needs to be adjusted. For custom orders, please contact Sanfeng company.
Pipe Fitting Thickness Measurement Gauges:

| Item Number | Resolution/Graduation Value (mm) | Measuring Range (mm) | Minimum Inner Diameter of Pipe Fitting (mm) | Indication Error (µm) | Force Measurement (N) | Mass (g) |
|---|---|---|---|---|---|---|
| 547-360A | 0.01 | 0 - 10 | Ø3.5 | ±20 | Below 1.5 | 250 |
| 7360A | 0.01 | 0 - 10 | Ø3.5 | ±15 | 1.4 or less | 220 |
Note: After replacing the probe, the indicator also needs to be adjusted. For custom orders, please contact Sanfeng company.
Lens Thickness Measurement Gauges:

| Item Number | Resolution/Graduation Value (mm) | Measuring Range (mm) | Measuring Depth (mm) | Stroke Range (mm) | Indication Error (µm) | Force Measurement (N) | Mass (g) |
|---|---|---|---|---|---|---|---|
| 547-313A | 0.01 | 0 - 10 | 30 | 12 | ±20 | Below 1.5 | 220 |
| 7313A | 0.01 | 0 - 10 | 30 | 12 | ±15 | 1.4 or less | 220 |
When measuring the thickness of a flat surface, it is necessary to replace the anvil with a spherical probe (e.g., SP4 ball probe, standard accessory).
5. Initial Setup
Before first use, ensure the gauge is clean and free from any debris. Follow these steps for initial setup:
- Unpacking: Carefully remove the thickness gauge from its packaging.
- Battery Installation: If not already installed, insert the appropriate battery into the battery compartment. Refer to the battery replacement section for details.
- Cleaning Measuring Surfaces: Gently wipe the measuring probe and anvil with a clean, lint-free cloth.
- Power On: Press the "ON/OFF" button to turn on the gauge.
- Zero Setting: With the measuring probe and anvil closed (no workpiece between them), press the "ZERO/SET" button to set the display to zero. This establishes the reference point for accurate measurements.
- Unit Selection (if applicable): If your model supports switchable units (e.g., metric/imperial), use the "MODE" button to select your desired unit (mm or inches).
6. Operation
Once the gauge is set up and zeroed, you can begin taking measurements:
- Prepare Workpiece: Ensure the surface of the workpiece to be measured is clean and free of dust or oil.
- Lift Probe: Gently press the lifting lever to raise the measuring probe.
- Position Workpiece: Carefully place the workpiece between the measuring probe and the anvil.
- Release Probe: Slowly release the lifting lever, allowing the probe to gently contact the workpiece. Avoid dropping the probe onto the workpiece, as this can affect accuracy and potentially damage the instrument or workpiece.
- Read Measurement: Read the thickness value displayed on the digital screen.
- Data Output (if applicable): If your model has a "DATA" button, you may be able to output measurement data to an external device (refer to specific model documentation for data output protocols).
- Absolute/Incremental Measurement: Use the "PRESET/ABS" button to switch between absolute measurement (from zero point) and incremental measurement (relative to a set point).
The gauge is designed for quick measurements with a single press, making it ideal for small components, paper, felt, and similar materials.
7. Maintenance
Proper maintenance ensures the longevity and accuracy of your Mitutoyo Digital Thickness Gauge.
Cleaning:
- Regularly clean the measuring surfaces (probe and anvil) with a soft, lint-free cloth.
- For models with ceramic probes and anvils (e.g., 547-301, 547-321, 547-400S, 547-400A), rust is generally not a concern. However, for models like 547-401a, which may not feature ceramic components, extra care should be taken to prevent rust.
- The integrated bezel and dial design helps prevent water or oil from seeping into the gauge, but avoid immersing the instrument in liquids.
Storage:
- Store the gauge in its original protective case when not in use.
- Keep the instrument in a dry environment, away from direct sunlight, extreme temperatures, and high humidity.
Battery Replacement:
When the display becomes dim or shows a low battery indicator, replace the battery. Refer to your specific model's diagram for battery compartment location. Typically, this involves:
- Turn off the gauge.
- Open the battery compartment cover.
- Remove the old battery.
- Insert a new battery of the correct type (e.g., SR44 or equivalent), ensuring correct polarity.
- Close the battery compartment cover securely.
- Perform a zero-setting procedure after battery replacement.
8. Troubleshooting
Here are some common issues and their potential solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Display does not turn on | Dead or incorrectly installed battery | Replace battery; check polarity. |
| Inaccurate readings |
|
|
| Display shows error message | Internal malfunction or sensor issue | Turn off and on again. If error persists, contact customer support. |
9. Warranty and Support
Mitutoyo products are manufactured to high standards and are backed by a manufacturer's warranty. For specific warranty terms, service, or technical support, please refer to the official Mitutoyo website or contact your authorized dealer. Keep your purchase receipt as proof of purchase.