The LIONSHEE LS-800Mi is an 800W micro inverter designed for converting direct current (DC) from solar photovoltaic (PV) modules into alternating current (AC) for grid-tied applications. Featuring two independent Maximum Power Point Trackers (MPPTs), Wi-Fi smart monitoring, and an IP67 waterproof rating, this micro inverter offers high efficiency, reliability, and ease of installation for residential, small industrial, and commercial solar power systems.

LIONSHEE LS-800Mi 800W Micro Inverter with various country codes and features

Image: The LIONSHEE LS-800Mi micro inverter, highlighting its 800W capacity and multi-region compatibility.

2. Technical Specifications

Category Parameter Value
General Brand LIONESHEE
Type Solar Inverter
Model LS-800Mi
Electrical Specifications Recommended PV Module Power 280W – 550W
Start-up Voltage 20V
MPPT Voltage Range 25V–55V
Max. Input Voltage 60V
Max. Input Current 13.5A × 2
Max. DC Short-Circuit Current 16.5A × 2
Number of MPPTs 2
Rated Output Power 800W
Nominal Output Voltage 230V
Extended Output Voltage Range 184V–253V
Nominal Output Current 3.47A
Max. Output Current 4A
Nominal Frequency / Range 50Hz / 45–55Hz
Power Factor >0.99 (default)
Total Harmonic Distortion (THD) <3%
Max. Units Per Branch 5
Peak Efficiency 96.0%
CEC Efficiency 95.5%
Static MPPT Efficiency 99.5%
Environmental & Mechanical Night-Time Power Consumption <50mW
Ambient Temperature Range -40℃ ~ +65℃
Enclosure Rating IP67
Cooling Natural Convection (No Fans)
Isolation Type High-Frequency Transformer
Communication Wi-Fi
Energy Management Solarmon Online Platform
Dimensions & Weight Product Weight 2.9 kg
Package Weight 3.5 kg
Product Size (L x W x H) 26 x 22.5 x 3.2 cm
Package Size (L x W x H) 36 x 28 x 12 cm
Technical Specifications table for LS-800Mi

Image: Detailed technical specifications of the LIONSHEE LS-800Mi Micro Inverter.

3. Package Contents

The standard package includes:

  • 1 x LIONSHEE LS-800Mi Micro Inverter
  • 1 x 5m AC Output Cable (EU Standard)
  • 1 x User Manual

4. Setup and Installation

The LS-800Mi micro inverter is designed for safe and easy plug-and-play installation. It supports a maximum DC voltage of 60V.

4.1. Mounting the Micro Inverter

The micro inverter can be installed in various locations, including balcony railings, roofs, garages, or freestanding in a garden. Ensure the mounting location allows for natural convection cooling and is protected from direct sunlight if possible, although the unit is IP67 rated.

Various installation locations for the micro inverter

Image: Examples of micro inverter installation locations: balcony, roof, garage, and garden.

4.2. Wiring Diagram

Connect your photovoltaic modules to the DC input connectors of the micro inverter. Each MPPT can handle one or more modules within the specified voltage and current ranges. The micro inverter then connects to your residential grid via the provided AC output cable and an EU standard socket.

Installation diagram showing two solar panels connected to the micro inverter and then to an EU socket

Image: Wiring diagram for connecting two solar panels (300-550W each) to the micro inverter and then to an EU socket using the 5m AC output cable.

Diagram showing the micro inverter with built-in MPPT connected to solar panels and feeding power into a house grid

Image: System diagram illustrating the flow of power from solar panels through the micro inverter to the household grid, with app monitoring.

4.3. Connecting Multiple Micro Inverters

For larger installations, multiple micro inverters can be connected in parallel. Ensure that the total number of units per branch does not exceed 5.

Microinverter installation example with two panels

Image: Example of a single micro inverter installation with two solar panels.

Microinverter installation example with multiple panels in series

Image: Example of connecting multiple micro inverters for a larger solar array.

Note: This package does not include solar panels. Only the 800W inverter is provided.

5. Operating Instructions

5.1. Powering On

Once the solar panels and AC output cable are securely connected, the micro inverter will automatically begin operation when sufficient sunlight is available. The indicator light on the inverter will show its status.

Clear overview diagram of the micro inverter components

Image: Overview of micro inverter components including PV connectors, AC output, mounting holes, indicator light, aluminum shell, waterproof design, and signal antenna.

5.2. Smart Monitoring with Solarmon App

The LIONSHEE LS-800Mi features built-in Wi-Fi for smart monitoring via the Solarmon online platform. This allows for real-time data monitoring, fault detection, and dynamic power adjustment.

  1. Download the Solarmon App from your smartphone's app store.
  2. Connect your micro inverter to your home Wi-Fi network following the app's instructions. The inverter can also connect directly via Bluetooth for initial setup.
  3. Once connected, you can track your power generation and consumption with intuitive visualizations.
Micro inverter with a smartphone displaying the Solarmon APP monitoring interface

Image: A smartphone displaying the Solarmon app interface for monitoring the micro inverter's performance.

Mobile APP Intelligent Monitoring via Wi-Fi or Bluetooth

Image: Mobile app intelligent monitoring, showing connection via Wi-Fi or Bluetooth.

Solarmon App interface showing daily production, consumption, etc.

Image: Screenshot of the Solarmon app interface, providing detailed energy production and consumption data.

6. Maintenance

The LIONSHEE LS-800Mi micro inverter is designed for minimal maintenance due to its durable construction and IP67 rating.

  • Regular Inspection: Periodically check the inverter and all cable connections for any signs of damage, corrosion, or loose connections.
  • Cleaning: If the inverter's surface becomes dirty, gently wipe it with a damp cloth. Do not use harsh chemicals or abrasive materials. Ensure the cooling fins are free from debris to maintain optimal heat dissipation.
  • Software Updates: Keep the Solarmon app updated to the latest version to ensure optimal performance and access to new features.
Micro inverter submerged in water, illustrating its IP67 waterproof rating

Image: The micro inverter demonstrating its IP67 waterproof capability, ensuring durability in various weather conditions.

Microinverter with 'WATERPROOF AND SUNSCREEN' features

Image: The micro inverter highlighting its waterproof, energy-saving, and sun protection features.

7. Troubleshooting

  • No Power Output (0V AC):
    • Symptom: Inverter indicator light alternates red and green, but no 220V AC output is detected.
    • Possible Causes: Incorrect grid connection, inverter not properly synchronized with the grid, internal fault, or incorrect programming.
    • Solution:
      1. Verify all AC and DC connections are secure and correctly wired according to the installation diagram.
      2. Ensure the grid voltage and frequency are within the inverter's operating range (230V, 50Hz).
      3. Check the Solarmon app for any error codes or diagnostic messages.
      4. If the issue persists, consult the full user manual for advanced troubleshooting or contact technical support.
  • Low Power Production:
    • Possible Causes: Shading on solar panels, dirty panels, suboptimal panel angle, or issues with individual MPPTs.
    • Solution:
      1. Clean solar panels regularly.
      2. Ensure panels are not shaded by trees or other obstructions.
      3. Check panel orientation and tilt for optimal sunlight exposure.
      4. Monitor individual panel performance via the Solarmon app to identify underperforming modules.
  • Wi-Fi Connection Issues:
    • Possible Causes: Weak Wi-Fi signal, incorrect password, or router issues.
    • Solution:
      1. Ensure the inverter is within range of your Wi-Fi router.
      2. Double-check the Wi-Fi password entered in the Solarmon app.
      3. Restart your Wi-Fi router and try connecting again.

8. User Tips

  • Initial Power Check: After installation, perform a quick power source test to ensure basic functionality before full grid connection.
  • Wi-Fi Setup: Users have reported smooth Wi-Fi connection to the Solarmon app, allowing for live monitoring of power output.
  • Verify Output: Always confirm 220V output after installation. If indicator lights show activity but there's no output, re-check connections and app diagnostics.

9. Warranty and Support

The LIONSHEE LS-800Mi Micro Inverter comes with a 10-year standard product warranty, ensuring long-term reliability and peace of mind. The product is designed for a lifespan of 25 years.

Customer service representatives and 10-year warranty badge

Image: Illustration of excellent customer service and a 10-year warranty.

9.1. Technical Support

For technical assistance, troubleshooting, or warranty claims, please contact LIONSHEE customer service. They offer 100% technical support and fast, reliable service.

How can I get help? section with icons for Local warehouse, Delivery, and Service

Image: Information on how to get help, including local warehouse support, delivery services, and 24-hour service.

9.2. Certifications

The LIONSHEE LS-800Mi Micro Inverter is VDE and CE certified, ensuring conformity with European safety and quality standards. It also features overvoltage protection for enhanced safety.

Micro inverter with '100% SAFETY' certification (VDE, CE) and overvoltage protection