1. Product Overview
The JIKONG SMART JKBMS JK-B2A24S30P is an intelligent battery protection board designed for large-capacity series lithium battery packs. It integrates advanced features to ensure optimal performance and longevity of your battery system.
Key functionalities include:
- Voltage Acquisition: Precise monitoring of individual cell voltages.
- High Current Active Balancing: Energy transfer between cells to maintain voltage consistency, extending battery life.
- Comprehensive Protection: Safeguards against overcharge, overdischarge, overcurrent, overtemperature, low temperature, and short circuits.
- Coulomb Meter: Accurate tracking of battery capacity.
- Communication Interfaces: Bluetooth for mobile APP control, GPS for location tracking (optional), RS485/CAN for system integration.
- Heating Function: Optional feature to warm batteries in low-temperature environments.
- Display Support: Interface for external display screens to view battery information.
This BMS is suitable for LiFePO4, Ternary Lithium (Li-ion), and Lithium Titanate (LTO) battery types, supporting configurations from 8S to 24S with a continuous charge/discharge current of up to 300A.
2. Specifications
2.1. General Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 10-36 | V |
| Operating Power Consumption | <900 | mW |
| Operating Temperature | -30 to 70 | °C |
| Maximum Number of Collection Strings | 8-24 | Strings |
| Maximum Balancing Current | 2 | A |
| Maximum Charging Current | 300 | A |
| Maximum Discharge Current | 300 | A |
| Maximum Instantaneous Current | 600 | A |
| Maximum Internal Loop Resistance | 0.3 | mΩ |
| Protective Plate Size | 174.77*127.26*17.6 | mm |
| Finished Weight | 421 | g |
2.2. Default Parameters (Example for LiFePO4)
The following table provides default parameter settings for LiFePO4 batteries. These can be adjusted via the APP.
| Parameter | LiFePO4 Default | Unit |
|---|---|---|
| Balancing Initial Voltage | 3 | V |
| Maximum Balancing Current | 2 | A |
| Unit Overcharge Voltage | 3.6 | V |
| Single Overcharge Protection Recovery | 3.55 | V |
| Monomer Undervoltage Protection | 2.6 | V |
| Single Undervoltage Protection Recovery | 2.65 | V |
| Automatic Shutdown Voltage | 2.5 | V |
| SOC-0% Voltage | 2.6 | V |
| SOC-100% Voltage | 3.5 | V |
| Trigger Balancing Differential Pressure | 0.01 | V |
| Charging Overcurrent Protection Delay | 30 | S |
| Charging Overcurrent Protection Release Time | 60 | S |
| Discharge Overcurrent Protection Delay | 300 | S |
| Discharge Overcurrent Protection Release Time | 60 | S |
| Short-circuit Protection Delay | 1500 | uS |
| Short-circuit Protection Release Time | 60 | S |
| Charging Overtemperature Protection Temperature | 70 | °C |
| Charging Overtemperature Restore Temperature | 60 | °C |
| Discharge Overtemperature Protection Temperature | 70 | °C |
| Discharge Overtemperature Recovery Temperature | 60 | °C |
| Charging Low Temperature Protection Temperature | -20 | °C |
| Charging Low Temperature Restore Temperature | -10 | °C |
| MOS Overtemperature Protection Temperature | 100 | °C |
| MOS Overtemperature Recovery Temperature | 80 | °C |
| Discharge Precharge Time | 0 (default 5) | S |
3. Package Contents
Please verify that all items are present and in good condition upon unpacking.
- BMS x 1
- Sampling Line x 1 (70cm long)
- NTC (Temperature Sensor) x 1 (40cm long)
- Switch x 1 (50cm long)
4. Installation and Wiring
4.1. Unpacking and Precautions
- Handle the packaging box and the protection board gently. Do not invert.
- Before unpacking, inspect the package for any impact marks or damage.
4.2. Interface Definition
The JKBMS features various interfaces for comprehensive battery management. Refer to the diagrams and tables below for detailed pinout information.
P1: Balance and Acquisition Interface (XH-10AW-2.54)
| Pin No. | Name | Definition |
|---|---|---|
| 1 | B- | Total negative battery |
| 2 | B1 | The first battery positive |
| ... | ... | ... (up to B8 for 8S, B24 for 24S) |
| 10 (or 24+1) | B+ | Protection board power supply, connected to the battery total positive |
P2: Heating Interface (A1254WF-7A)
| Pin No. | Name | Definition |
|---|---|---|
| 1-4 | HT- | Heater element negative electrode |
| 6 | CD+ | Charge indication input positive terminal |
| 7 | CD- | Charge indication input negative terminal |
P3: Display Interface (A1254WF-6A)
| Pin No. | Name | Definition |
|---|---|---|
| 1 | VCC | Display power output |
| 2 | A | Display RS485 signal positive |
| 3 | B | Display RS485 signal negative |
P4: Communication Interface (A1254WF-4A)
| Pin No. | Name | Definition |
|---|---|---|
| 1 | 485 B | RS485 signal negative terminal |
| 2 | 485 A | RS485 signal positive terminal |
| 3 | CAN H | CAN signal positive terminal |
| 4 | CAN L | CAN signal negative terminal |
P5: GPS Interface (1.25T-4PWT)
| Pin No. | Name | Definition |
|---|---|---|
| 1 | VGPS | Power output, voltage close to B+ |
| 2 | TX | UART TX, 3.3V |
| 3 | RX | UART RX, 3.3V |
| 4 | GND | Power/signal ground |
P6: Temperature Interface 1 (HY2.0-4P)
| Pin No. | Name | Definition |
|---|---|---|
| 1 | T1A | First temperature sensor pin A |
| 2 | T1B | First temperature sensor pin B |
| 3 | T2A | Second temperature sensor pin A |
| 4 | T2B | Second temperature sensor pin B |
P7: Temperature Interface 2 (HY2.0-4P, 4 external optional configuration)
| Pin No. | Name | Definition |
|---|---|---|
| 1 | T3A | Third temperature sensor pin A |
| 2 | T3B | Third temperature sensor pin B |
| 3 | T4A | Fourth temperature sensor pin A |
| 4 | T4B | Fourth temperature sensor pin B |
P8: Parallel Interface (A1254WF-3A)
| Pin No. | Name | Definition |
|---|---|---|
| 1 | GND | Signal ground |
| 2 | P-EN | Parallel module enable signal, output low level to turn on parallel module |
| 3 | P-status | Parallel module status signal |
P9: Buzzer Interface (A1254WF-2A)
| Pin No. | Name | Definition |
|---|---|---|
| 1 | VCC | Buzzer power supply positive |
| 2 | GND | Buzzer power negative |
Other Connections
- D1 (Bluetooth connection indicator): When Bluetooth is connected, the indicator is steady on. When disconnected, it blinks.
- P-: Connect to external load or negative terminal of charger.
- B-: Connect to the negative battery terminal.
4.3. Wiring Diagrams
The JKBMS JK-B2A24S30P is suitable for 3-8 series and 8-24 series lithium battery packs. The specific wiring method depends on the number of cells in your battery pack.
General Wiring Steps:
- Connect all the balance cables (P1 connector) to the battery cells, ensuring correct polarity for each cell.
- Insert the balance cable into the BMS.
- Connect the B- line (from the battery's total negative) and the P- line (from the load/charger negative) to the BMS.
- Connect the B+ line (from the battery's total positive) to the BMS power input.
5. Operation
5.1. APP Installation and Activation
The JIKONG BMS is controlled and monitored via a mobile application available for Android and iOS. Android Version 7 or higher is required.
- APP Installation: Scan the QR code below to download the official JIKONG BMS APP.
- Device Activation:
- Before powering on the BMS, ensure all balance cables (P1 connector) are properly connected and that P- and B- connections are correct.
- Verify the BMS is securely fixed to the battery pack. Incorrect connections can lead to abnormal operation or damage.
- The BMS does not have a physical power-on switch. It is designed for charging activation: connect a charger (with voltage 2V higher than battery voltage) to the battery pack after assembly to power on the BMS.
- Alternatively, if an optional display screen and button are connected, insert the cable into the display interface and press the button to activate.
- Parameter Setting: Once activated, use the APP to set various parameters according to your battery type and specific needs. Refer to the 'Default Parameters' section for initial values.
5.2. Key Functions
- Active Equalization (Lossless Balancing): The BMS employs energy transfer active balancing, moving energy from higher voltage cells to lower voltage cells. This process is continuous during charging, discharging, or idle states until voltage differences are minimized. The default balancing current is 2A.
- GPS & Display Interface: The BMS includes a reserved GPS port for optional location tracking and a display interface for connecting external screens to view battery data.
- Heating Function (Optional): For low-temperature environments, the BMS supports an optional heating function using a resistance heater or heating film to maintain battery activity. The designed heating current is 4A.
- Alarm Function: The BMS provides an alarm function to alert users to potential safety risks such as overtemperature, overcharge, or overdischarge.
- Battery Parallel Function (Optional): Supports parallel connection of battery packs, requiring a parallel module and activation of the charging current limiting function in the APP.
- Intelligent Sleep: To reduce self-consumption, the BMS can enter an intelligent sleep mode when in standby (charging/discharging current less than 1A for 26 consecutive hours). It can be reactivated via button or charger.
- Communication Function: Supports optional CAN/RS485 communication. Users can select the communication type and set the address/protocol via the APP.
5.3. Protection Features
The JKBMS provides robust protection mechanisms to ensure the safety and longevity of your battery pack:
- Overcharge Protection: Automatically stops charging if any cell voltage exceeds the set overcharge protection voltage. Charging resumes when all cell voltages drop below the recovery voltage.
- Discharge Undervoltage Protection: Stops discharge if any cell voltage falls below the set undervoltage protection voltage. Discharge resumes when all cell voltages rise above the recovery voltage. The BMS will automatically shut down if any cell voltage drops below the automatic shutdown voltage.
- Charge Overcurrent Protection: Stops charging if the charging current exceeds the set limit for a specified delay. Charging resumes after the overcurrent release time.
- Discharge Overcurrent Protection: Stops discharge if the discharge current exceeds the set limit for a specified delay. Discharge resumes after the overcurrent release time. (Maximum continuous discharge current should not exceed 300A).
- Overtemperature Protection: Stops charging/discharging if the battery temperature exceeds the set overtemperature protection value. Operation resumes when the temperature drops below the recovery value.
- Low Temperature Protection: Stops charging if the battery temperature falls below the set low temperature protection value. Charging resumes when the temperature rises above the recovery value.
- Short Circuit Protection: Automatically protects against short circuits. Users can adjust the short circuit protection delay and recovery time via the APP.
- Discharge Precharge Function (Optional): Allows for a precharge period (default 5 seconds) before full discharge. This can be enabled/disabled via the APP.
- Emergency Switch: In case of critical issues (overtemperature, overdischarge, overcharge, cell drop), activating the emergency switch via the APP will enable charge and discharge for 30 minutes, providing an emergency use time.
6. Maintenance
- Regular Inspection: Periodically check all wiring connections for tightness and signs of wear or corrosion.
- Cleaning: Keep the BMS board clean and free from dust and debris. Use a soft, dry cloth for cleaning. Avoid using liquids or solvents.
- Software Updates: Ensure your mobile APP is updated to the latest version to benefit from new features and bug fixes.
- Parameter Review: Periodically review the parameter settings in the APP to ensure they are still appropriate for your battery pack's condition and usage patterns.
- Environmental Conditions: Operate the BMS within its specified temperature range (-30°C to 70°C) to ensure optimal performance and longevity.
7. Troubleshooting
This section provides guidance for common issues. For complex problems, refer to the detailed PDF manual or contact support.
- BMS Not Powering On: Ensure the charger is connected (voltage 2V higher than battery voltage) or the optional activation button is pressed. Verify all B- and P- connections are correct.
- Balancing Not Occurring: Check the active equalization settings in the APP. Ensure the trigger balancing differential pressure is met and the balancing function is enabled.
- Frequent Protection Triggers:
- Overcharge/Undervoltage: Verify cell voltages are within safe limits. Adjust protection thresholds in the APP if necessary, ensuring they match your battery's specifications.
- Overcurrent: Check the load and charger current. Increase overcurrent delay times in the APP if transient current spikes are causing false triggers (e.g., during motor startup). Ensure total current does not exceed 300A.
- Overtemperature/Low Temperature: Ensure proper ventilation and environmental conditions. If operating in cold climates, consider enabling the heating function.
- Short Circuit: If a short circuit protection triggers upon connecting a load, increase the short circuit protection delay in the APP. Ensure external wiring is free of actual shorts.
- APP Connection Issues: Ensure Bluetooth is enabled on your mobile device and the BMS. Try restarting both the APP and the BMS.
- Inaccurate Readings (Voltage, Current, SOC): Calibrate the voltage and current sensors via the APP's parameter settings if discrepancies are observed.
8. User Tips
- Balancing Current: When setting the active balancing current in the APP, it is recommended not to exceed 0.2C of your battery's capacity (C).
- Heating Function: For optimal battery protection in extremely cold environments, utilize the optional heating function. If using a heater, consider adding a normally closed temperature switch (45°C to 65°C) in series with the heating circuit as a secondary safety measure to prevent thermal runaway.
- Parameter Customization: Always read the internal parameters of the protection board first before making adjustments to overcharge, overdischarge, overcurrent, temperature, and balance values.
- Initial Setup: During the first connection of a charger or load, if a short circuit protection is triggered, try increasing the short circuit protection delay in the APP. This can help accommodate high instantaneous peak currents from certain devices.
9. Further Information and Support
For more detailed technical specifications, advanced parameter settings, and comprehensive wiring diagrams, please refer to the official user manual PDF:
Manufacturer: Chengdu Jikong Technology Co.LTD