FDIK FDIK water heater

Contents

FDIK 5KW 12V Water Heater Plumbing User Manual

Model: FDIK Water Heater (5KW, 12V)

1. Introduction

Thank you for choosing the FDIK 5KW 12V Water Heater. Please read this manual carefully before installation and follow all requirements to ensure safe and efficient operation.

This manual explains the working principle and process of the pre-heater, as well as detailed installation methods and precautions. The automotive fuel preheater is a product that combines precision casting, welding, machining, automatic control, and combustion engineering. Therefore, professional installation and maintenance are highly recommended.

For a complete reference, please consult the official user manual PDF: FDIK Water Heater User Manual (PDF)

2. Product Information and Specifications

The FDIK 5KW 12V Water Heater is designed for engine heating, providing efficient warmth for your vehicle. It features an LCD control for easy operation.

FDIK 5KW 12V Water Heater main unit

Figure 1: FDIK 5KW 12V Water Heater Main Unit

Key Features:

  • Fast heating capability.
  • Designed for over 2000 hours of operation.
  • Double overheat protection for safety.
  • Easy installation.
  • External power supply.
  • Thermal control.
FDIK Hydronic features: Fast heating, 2000+ hours, double overheat protection

Figure 2: FDIK Hydronic Key Features

Technical Specifications:

Attribute Specification (HE-1 Pro) Specification (HE-2)
Structure Type Fuel type water heating type heater
Max. Heating Power 6.0KW 12.0KW
Min. Heating Power 2.8KW 2.8KW
Max. Oil Consumption (+/- 10%) 0.62L/H 1.15 L/H
Min. Oil Consumption (+/- 10%) 0.30L/H 0.45 L/H
Rated Voltage 12.4V
Operating Voltage Range 11.5V-16V
Rated Voltage Consumption (without circulation pump and on-board fan) 33W (Max), 15W (Min) 33W (Max), 15W (Min)
Work Temperature Range -40°C - +80°C
Dimensions (Length × Width × Height) 210 × 91 × 147 mm
Weight 6.5 kg

Included Components:

The product package typically includes the main heater unit, LCD control panel, remote control, silencer, oil pump, water pump, hoses, air filter, wire harness, various pipes, oil pump clamp, screw accessories kit, exhaust pipe, and a fixed plate.

Diagram showing all included components: heater, LCD control, remote, silencer, oil pump, water pump, hoses, air filter, wire harness, pipes, oil pump clamp, screws, exhaust pipe, fixed plate.

Figure 3: Typical Accessory Kit Contents

3. Setup and Installation

3.1. General Installation Guidelines

  • The preheater generates high temperatures; avoid installing it near brake fluid pipes or other heat-sensitive devices.
  • The preheater requires heat radiation for proper internal working temperature; do not install it near the engine's exhaust pipe.
  • The highest installation position of the preheater should be at least 10cm lower than the antifreeze filling surface of the car.
  • The lowest installation position of the preheater should be at least 10cm above the wading surface of the car.
  • The preheater harness plug side must not face upwards to prevent water ingress or damage.
  • Install the heater in the engine compartment, the waterproof splash protection area of the front mudguard, or on the mudguard itself.
  • Install the heater at the lowest possible position to ensure automatic filling of coolant in both the heater and the water pump.

3.2. Heater Body Installation

The installation angle of the preheater includes horizontal and vertical orientations. Other methods may prevent proper operation.

Internal diagram of the heater showing water inlet, water outlet, air inlet, air outlet, and oil inlet.

Figure 4: Heater Internal Flow Diagram

Important Note: The heater must comply with the specified installation directions (0-90° range). The inlet and outlet must never face downward. Avoid installing near high-temperature components or within the direct splash zone of the vehicle's wheels.

Diagram illustrating acceptable installation angles for the heater body, showing 0-90 degree ranges for different orientations.

Figure 5: Heater Installation Angle Guidelines

3.3. Circulating Water Circuit Installation

  1. Install the heater in the middle of the engine's outlet and the car heater heat exchanger.
  2. Ensure correct water flow direction: engine outlet → pre-heater water pump inlet (central axis) → pre-heater water pump outlet (tangential) → pre-heater cooling water inlet (marked "in") → pre-heater cooling water outlet (marked "out") → car heater heat exchanger.
  3. The circulating water pump should be installed lower than the pre-heater.
  4. Fasten water pipe joints with pipe clamps from the accessory package.
  5. Bolt the water pump to the car body. Overhanging installation can lead to wire breakage and water pipe leakage.
  6. Do not extend the water pump wiring harness. The specified length is critical for proper pre-heater function.
  7. Pay attention to antifreeze loss during installation. Replenish with the same specification of antifreeze after installation and refill to capacity after engine cycling.
  8. Install the water pump at least 30cm below the antifreeze level to prevent air in the pipeline, which can cause overheating and fault codes.
Diagram showing the water pump and combustion chamber components.

Figure 6: Water Pump and Combustion Chamber Details

Water Pump Connection Method: The water pump's water mouth end must not face down to avoid trapping air and affecting circulation.

Diagram illustrating correct and incorrect water pump water mouth end orientations to prevent air trapping.

Figure 7: Water Pump Orientation for Air Exclusion

3.4. Oil Line Installation

  1. Relieve tank pressure by opening the tank cover before installing the oil picker. Exercise fire prevention during fuel tank work.
  2. The fuel extractor should be positioned 5cm above the bottom of the fuel tank to prevent running out of fuel.
  3. Bend the fuel pickup tube properly to fit irregular fuel tank bottoms.
  4. Install the fuel pump near the fuel tank. Ensure the fuel pump outlet (plug side) is correctly oriented.
  5. Do not route the fuel pipe inside the vehicle cabin. Lay it alongside the original fuel pipe and secure with nylon ties every 15cm.
  6. Avoid laying the fuel line through heat-generating parts (e.g., exhaust port, silencer, air conditioning pump).
  7. Use the rubber hose from the accessory package to connect the fuel line and fasten with hose clamps. The two fuel pipes inside the rubber hose should be closely connected, and the fuel pump bolted to the car body.
Diagram showing preferred installation angles for the fuel pump (1 and 2) and the tee connection.

Figure 8: Fuel Pump and Tee Installation Angles

The fuel pipe butt must be contacted on both ends. If a turn is needed, ensure no downward bend to avoid air bubble collection.

Diagram illustrating correct fuel pipe butt connection without downward bends to prevent air bubbles.

Figure 9: Fuel Pipe Connection Best Practices

3.5. Intake and Exhaust Installation

  1. The preheater has a protective shield at the air inlet. Ensure the air inlet does not face the direction of vehicle travel to allow proper combustion air absorption.
  2. The air inlet must be well ventilated.
  3. The exhaust pipe temperature can reach 300°C. Avoid installing it near plastic parts or other temperature-sensitive components.
  4. The exhaust pipe must face downward to the ground, and its mouth must not be lower than the engine guard.
  5. Use pipe clamps to fasten the exhaust pipe to the pre-heater interface. Apply appropriate tightening force to prevent deformation and air leakage.
  6. The exhaust pipe can be bent at various angles for installation.
  7. The exhaust pipe length is specially designed; do not change its length or omit it.
  8. Fix the end of the exhaust pipe to the car body using pipe clamps and brackets from the accessory package.

3.6. Wiring Harness Laying

  1. Connect the wiring harness according to the labels and matching colors.
  2. Do not extend any connecting wires.
  3. Replace fuses with the same specifications. Do not use larger-sized fuses.
  4. Avoid exposing the wiring harness to high-temperature radiation.
  5. Fasten the wiring harness with nylon ties from the accessory package to prevent wear and tear from vibration.

Wiring Instructions:

Color Signal Description
Red Power positive Working voltage 10-30V
Brown Negative power supply GND
Orange Main board power signal Main board power signal line
Yellow Communication line K-line communication
Black Switch indicator ground GND
Gray Switch signal line Control switch signal
Green Switch indicator line 5V indicator power

4. Operation

4.1. Control Panel Overview

The LCD control panel allows for easy interaction with the heater. Familiarize yourself with the buttons:

  • Up Button (▲): Increases output power in gear mode; moves parameter up during setting. In shutdown, long press to enter remote control pairing.
  • Down Button (▼): Reduces output power in gear mode; moves parameter down during setting. In shutdown, long press to manually turn on the pump.
  • Power Button (⏻): Short press to turn on, long press to turn off.
  • Setting Button (⚙): Enters parameter setting state to change plumbing working parameters.
  • OK Button (OK): Confirms running parameters, sets status, and confirms running parameters.
Image showing the LCD control panel and remote control for the heater.

Figure 10: LCD Control Panel and Remote Control

4.2. Checking Machine Status

Short press the OK button to cycle through display states:

  • Water temperature display
  • Ambient temperature display
  • Gear display (gear mode) / remaining time (time mode)
  • Power supply voltage display

4.3. Manual Fuel Filling

In shutdown state, press and hold the Down (▼) and OK buttons simultaneously to enter manual fuel injection (display 'OF'). After releasing, press Up (▲) to start the oil pump (display 'ON'). You will hear the pump working, and the oil pump icon will light up. Press Down (▼) to exit fuel injection (display 'OF'), and the oil pump icon will disappear. Observe the air process of the empty pipeline. Stop when oil reaches the machine's oil inlet. Excessive fuel can cause black smoke during ignition.

4.4. Manual Separate Switching Pump

In shutdown state, long press the Down (▼) key to enter the pump control interface (display 'P OF'). Then press the Up (▲) button to display 'P ON', activating the pump.

4.5. Working Mode Switching

Press and hold the Up (▲) and Setting (⚙) keys simultaneously to switch between gear mode and time mode:

  • Gear Mode: (e.g., L-05 for 6 gears) Suitable for new energy models.
  • Time Mode: (e.g., H-40 for 40 minutes) Suitable for regular preheating.

In both modes, heating automatically shuts down when the upper limit temperature is reached, even if the set heating time has not elapsed.

4.6. Remote Control Pairing

In shutdown state, long press the Up (▲) button to enter the remote control code-to-code interface (display 'HFR'). Press the On key on the remote control to initiate pairing. If successful, the interface will automatically exit. If pairing fails or times out, it will not enter the power-on state.

5. Maintenance

5.1. Excluding Gas in the Circulating Water

  1. After installing all parts, start the car and run it at a high RPM for a period to eliminate gas from the circulating water circuit. Monitor and replenish antifreeze as needed.
  2. Failure to evacuate gas can lead to a high-temperature alarm from the heater.

5.2. Coolant Level Management

Note: Before initial use or after replacing coolant, ensure the circulation system is fully topped up. Insufficient coolant can lead to overheating, fault codes, malfunction, and shutdown.

5.3. General Checks

  • Regularly inspect all hose and pipe connections for leaks or damage.
  • Check the wiring harness for any signs of wear, fraying, or loose connections.
  • Ensure the air inlet and exhaust outlets are clear of obstructions.
  • Periodically check the fuel filter for cleanliness and replace if necessary.

6. Troubleshooting

Refer to the following table for common fault codes and their corresponding troubleshooting methods:

Water Heating Controller Fault Code Table:

Number Fault Code Fault Description Troubleshooting Methods
1 E-01 Supply undervoltage Raise the power supply voltage, or check whether the switch voltage parameter is set correctly
2 E-02 The power overvoltage Reduce the power supply voltage, or check whether the switch voltage parameter is set correctly
3 E-03 Ignition plug fault Check the ignition plug for short circuits, broken wires, or replacement with a mismatched model
4 E-04 Oil pump failure Check whether the oil pump has short circuit or broken wire
5 E-05 The machine is overheating Check whether the water circulation is poor or the upper heating temperature is set too high
6 E-06 Fan motor fault The motor terminal is in poor contact with the circuit board, or the air wheel clearance is too small, or the hall signal is lost
7 E-07 Communication failure Motherboard and switch communication lost, check the connector, wire. Or replace the switch, motherboard
8 E-08 The flame is extinguished Fuel supply is insufficient, or oil pump failure can not pump oil, or flame sensor failure
9 E-09 The flame temperature sensor is faulty The flame temperature sensor is disconnected, short-circuited, or mismatched
10 E-10 Ignition failure No normal oil supply or combustion chamber carbon accumulation or failure of the flame sensor to detect normal temperature rise
11 E-11 The water circulating pump is fault The plug is not reliably connected, or the pump connection wire is disconnected
12 E-12 Poor circulation in waterways The motor current of the pump is too high, the pump is stuck, or the model of the pump is not matched
13 E-13 Water temperature sensor fault The water temperature sensor is disconnected or short-circuited
14 E-14 The heating temperature sensor is faulty The heating temperature sensor is disconnected or short-circuited

7. User Tips

  • Fuel Type: This heater is compatible with both diesel and gasoline. Ensure you are using the correct fuel type and that any necessary configuration for fuel type is performed according to the instructions.
  • Accessory Check: The wire harness and other essential installation components are included in the accessory package. Verify all parts are present before beginning installation.
  • Coolant Management: Always ensure the coolant system is fully topped up before operating the heater, especially after installation or maintenance, to prevent overheating and potential fault codes.
  • Professional Installation: Due to the complexity involving fuel, water, and electrical systems, professional installation is highly recommended to ensure safety and optimal performance.

8. Frequently Asked Questions (FAQ)

Q: Is a 24V version of this heater available?
A: This manual covers the 12V model. Please check the product listings or contact the seller for information on available 24V variants.
Q: Is specific setup required for gasoline fuel?
A: The heater is compatible with both diesel and gasoline. Ensure the correct fuel type is used and any necessary configuration for fuel type is performed according to the instructions provided in this manual.
Q: Are cables included with the heater?
A: Yes, a complete wire harness is included in the accessory package for installation.
Q: Can this heater be used for heating small rooms (e.g., 10m2 with underfloor heating)?
A: While primarily designed for vehicle engine heating, some users adapt similar units for heating small spaces. However, for such applications, it is crucial to ensure adequate ventilation, proper exhaust routing to the outside, and strict adherence to all safety guidelines for indoor combustion devices, as this is not its primary intended application.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the product packaging or contact the seller directly. This manual does not contain specific warranty details or support contact information.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.