1. Product Overview
The Jesverty SPS3010C is a professional laboratory adjustable DC power supply designed for various applications including laboratories, educational sites, factory manufacturing tests, maintenance repairs, battery charging, anodizing, and electronic DIY projects. It features a high-precision 4-digit LED display, USB fast charging, intelligent battery charging, and multiple protection functions.
Product Highlights:
- Coarse & Fine Encoder Knobs: Upgraded from traditional potentiometers for precise voltage and current setting (0.01V/0.001A resolution).
- USB-A & USB-C 20W Quick-Charge: Dual charging ports for smartphones and electronic modules.
- Intelligent Battery Charging: Activates with a single button press, displays charging power (Ah), and automatically stops when the battery is full. Includes reverse connection protection.
- Multiple Protection Functions: Output ON/OFF control, OCP (Over-Current Protection), Temperature-regulated cooling fan, OPN (Output Status Setting).
- Compact & Lightweight Design: Measures approximately 7.1(D) x 3.6(W) x 6.2(H) inches and weighs about 2.5 lbs (1.14 kg).
2. Setup
2.1 Package Contents
Upon unboxing, ensure all items are present:
- 1 x SPS-C Unit
- 1 x Power Cord (AC input settings vary by destination)
- 1 set of Test Leads
- 1 x Instruction Manual
2.2 Component Identification
- Voltage Display
- C.C. Mode Indicator (Constant Current)
- CHG Mode Indicator (Charging)
- C.V. Mode Indicator (Constant Voltage)
- Current Display
- OCP Status LED (Over-Current Protection)
- OPN Status LED (Output Status Setting)
- Power Display
- USB-C Quick-Charge Port
- USB-A Quick-Charge Port
- CHG Setting Button (Intelligent Battery Charging)
- OCP Setting Button (Over-Current Protection)
- Output Control Button (OUT)
- Voltage Knob (Coarse)
- Voltage Knob (Fine)
- Current Knob (Coarse)
- Current Knob (Fine)
- Power Switch (Green button)
- Output Terminal - (Black)
- Grounding Terminal (Green)
- Output Terminal + (Red)
- Cooling Fan
- Input Selectable Switch (AC115V/230V)
- AC Power Inlet
- Fuse Box (Spare Fuse Included)
2.3 Initial Connection
- AC Input Selection: Locate the Input Selectable Switch (23) on the rear of the unit. Ensure it is set to the correct voltage (AC115V or AC230V) for your region before connecting the power cord.
- Connect Power Cord: Plug the provided power cord into the AC Power Inlet (24) on the rear of the unit, and then into a suitable wall outlet.
- Connect Test Leads: Connect the test leads to the Output Terminal - (19, Black), Grounding Terminal (20, Green), and Output Terminal + (21, Red) as required for your application.
3. Operating Instructions
3.1 Power On/Off
- To turn on the power supply, press the green POWER button (18) lightly.
- To turn off the power supply, press the green POWER button (18) again.
3.2 Adjusting Voltage and Current
The SPS3010C uses encoder knobs for precise adjustments:
- Voltage Adjustment:
- Use the V-COARSE knob (14) to adjust the value of the first two digits (coarse adjustment).
- Use the V-FINE knob (15) to adjust the value of the last two digits (fine adjustment).
- Current Adjustment:
- Use the A-COARSE knob (16) to adjust the value of the first two digits (coarse adjustment).
- Use the A-FINE knob (17) to adjust the value of the last two digits (fine adjustment).
3.3 Output Control (OUT Button)
- After setting the desired voltage and current, press the OUT button (13) lightly to turn on the output.
- Press the OUT button (13) again to turn off the output. The display will show "OFF".
3.4 Over-Current Protection (OCP)
- The red OCP button (12) enables the OCP function.
- Press the OCP button lightly to enter the OCP setting interface.
- Rotate the V-COARSE knob (14) to change the OCP setting from "0" to "1". The OCP indicator light (6) will turn on, indicating that OCP is enabled.
- Press the OCP button again to return to the main interface.
- If an overcurrent or short circuit occurs, the OCP indicator light (6) will flash, triggering an alarm and stopping output to protect the load device.
3.5 USB Charging Function
- The unit features USB-C (9) and USB-A (10) charging ports.
- These ports support 20W fast charging and can be used to charge mobile phones or power other compatible devices.
- The green display area on the unit shows various supported fast-charging protocols when a device is connected.
3.6 Intelligent Battery Charging (CHG)
- The gray CHG button (11) enables the intelligent battery charging function.
- Press the CHG button lightly to activate it. The "CHG" indicator light (3) will turn on.
- The "Ah" display (next to OPN) represents ampere-hour, showing the energy charged into the battery.
- The power supply will automatically stop charging when the battery is fully charged, indicated by the "CHG" indicator light flashing.
- Reverse-Polar Connection Protection: If the battery is connected with reverse polarity, the display will show "EER". Correct the wiring, then press the OUT button (13) again. If "EER" disappears, charging can proceed normally.
- If the charging cables are disconnected during charging, the "CHG" indicator light will flash, indicating an abnormal charging function. Press the CHG button lightly to turn off the intelligent charging function, then press it again to reset it. Reconnect the power cord to continue charging.
3.7 OPN (Output Status Setting)
- OPN is a function that allows the unit to output voltage and current as soon as you turn the power switch on, without needing to push the "OUTPUT" button (13).
- Refer to the instruction manual for specific steps to enable or disable OPN mode.
3.8 Video Demonstration
4. Maintenance
- Cooling Fan: The unit is equipped with a temperature-regulated cooling fan (22) to prevent overheating. Ensure the fan vents are not obstructed to allow for proper airflow.
- Fuse Replacement: The fuse box (25) is located near the AC power inlet. If the unit fails to power on, check and replace the fuse if necessary. Always use a fuse with the correct rating.
- Cleaning: Keep the unit clean and free from dust. Use a soft, dry cloth for cleaning. Avoid using abrasive cleaners or solvents.
5. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not power on. | No power from outlet, power cord not connected, or blown fuse. | Check wall outlet, ensure power cord is securely connected, check and replace fuse (25) if necessary. |
| Display shows "EER" during battery charging. | Reverse polarity connection of battery. | Correct the battery wiring (positive to positive, negative to negative). Press the OUT button (13) to clear the error and resume charging. |
| "CHG" indicator light flashes during charging. | Charging cables disconnected or abnormal charging function. | Reconnect cables. Press the CHG button (11) lightly to turn off, then press again to reset. Reconnect power cord to continue charging. |
| "EER" sign appears briefly after power cycle. | Output terminal is still discharging residual electricity. | This is normal. The sign should disappear quickly. If it persists, check connections. |
| OCP indicator light flashes. | Overcurrent or short circuit detected. | Disconnect the load, check for short circuits or excessive current draw. Adjust current limit or fix the load issue. |
6. Specifications
| Feature | Detail |
|---|---|
| Model Number | SPS-C |
| Brand Name | Jesverty |
| Type | Other (Adjustable DC Power Supply) |
| Current Type | AC |
| Phase | Single phase |
| Certification | CE |
| Origin | Mainland China |
| Use | SVC |
| Dimensions (D x W x H) | Approx. 7.1 x 3.6 x 6.2 inches (18 x 9 x 16 cm) |
| Weight | Approx. 2.5 lbs (1.14 kg) |
| Package Dimensions (L x W x H) | 29 x 12 x 23 cm |
| Package Weight | 1.59 kg |
7. User Tips
- Test Lead Quality: The included test leads are suitable for general use. For long-term applications involving high current, it is recommended to use test leads with sufficient current capacity to ensure stable performance and safety.
- AC Input Voltage: Always double-check the AC input selectable switch on the back of the unit to match your local voltage (115V or 230V) before plugging in the power supply. Incorrect voltage selection can damage the unit.
- Understanding OPN Mode: If you prefer the power supply to output immediately upon turning it on, enable the OPN (Output Status Setting) function. Otherwise, remember to press the 'OUT' button after setting your desired voltage and current.
- Battery Charging Safety: Always ensure correct polarity when connecting batteries for charging. The built-in reverse connection protection will alert you with an "EER" message if connected incorrectly, but it's best practice to verify connections visually.
8. Warranty and Support
Your Jesverty SPS3010C unit comes with a standard manufacturer's warranty. For detailed warranty information, please refer to the warranty card included in your product packaging or contact Jesverty Customer Service.
For any technical support, questions, or issues regarding your product, please feel free to contact Jesverty Customer Service via the contact information provided on the back of your instruction manual or through the seller's platform.