1. Product Overview
The JIKONG V19 BMS (Battery Management System) is an intelligent protection board designed for large-capacity series lithium battery packs. It integrates advanced features such as voltage acquisition, high-current active balancing, overcharge, over-discharge, over-current, and over-temperature protection, along with a coulomb meter, Bluetooth communication, and host computer monitoring capabilities.
This BMS is suitable for various battery types, including lithium iron phosphate (LiFePo4), ternary lithium (Li-Ion), and lithium titanate (LTO). It is engineered to ensure battery consistency, extend battery life, and enhance overall performance in applications such as high-power energy storage, base station backup power supplies, and solar power stations.
The system utilizes an energy transfer active balancing technology with a continuous 2A balance current, significantly improving battery consistency and delaying aging. It features a mobile APP for Android and iOS, allowing users to monitor battery status in real-time and adjust parameters via Bluetooth.
2. Specifications
The JIKONG V19 BMS JK-PB2A16S30P offers robust performance and a comprehensive set of features. Below are the detailed specifications:
| Feature | Specification | Unit |
|---|---|---|
| Model | JK-PB2A16S-30P | - |
| Battery Series Supported | 8S-16S | Strings |
| Battery Types Supported | Li-ion, LiFePo4, LTO | - |
| Continuous Charge Current | 300 | A |
| Continuous Discharge Current | 300 | A |
| Max Instantaneous Current | 600 | A |
| Active Balancing Current | 2 | A |
| Single Cell Voltage Range | 1-5 | V |
| Voltage Acquisition Accuracy | ±5 | mV |
| Supply Voltage | 20-70 | V |
| Operating Temperature | -30 to 70 | °C |
| Max Internal Loop Resistance | 0.25 | mΩ |
| Dimensions (L*W*H) | 300*100*24 | mm |
| Weight | 1000 | g |
| Communication Interfaces | Bluetooth, RS485 (2 channels), CAN, UART, RS232 | - |
| Protection Functions | Overcharge, Over-discharge, Overcurrent, Overtemperature, Low Temperature, Short Circuit | - |
| Other Features | Heating Function, Dry Contact (2 channels), Emergency Switch, Intelligent Sleep, Parallel Current Limiting | - |
3. Installation and Wiring
Proper installation and wiring are crucial for the safe and efficient operation of your JIKONG V19 BMS. This section provides a guide to the physical installation and electrical connections.
3.1. Packing List
Before you begin, ensure all components are present in the package:

- BMS x 1
- Interface board x 1
- Adapter cable B x 1 (long 30cm)
- Adapter cable A x 1 (long 30cm)
- R545 Network cable x 1 (long 40cm)
- Cells total B+ Cable x 1 (long 50cm)
- Sampling line A x 2 (long 90cm)
- Sampling line B x 1 (long 90cm)
- Sampling line C x 1 (long 90cm)
- Switch x 1 (long 50cm)
- Adapter cable C x 1 (long 30cm)
- Heating Adapter cable x 1 (long 17cm)
- Adapter x 1
3.2. Physical Installation
The BMS unit should be securely fixed to the battery pack. Ensure there is adequate ventilation around the unit for proper cooling.
3.3. Wiring Instructions
The wiring method varies depending on the number of battery strings (8-string or 16-string). Always connect all balance cables first, then the B-line and P-line to the battery. Note that if there are two B8 cables, only the first B8 line needs to be connected; the second B8 cable is not required.

General Wiring Steps:
- Connect all balance cables to the corresponding battery cells.
- Insert the balance cable connector into the BMS.
- Connect the B-line (battery negative) and P-line (load/charger negative) to the battery.
- If using the heating function, connect the heater element and temperature control switch as shown in the diagram.
- Connect the inverter, charger, and motor as per your system requirements.
3.4. Interface Board Connections
The interface board provides various ports for communication, display, and control. Refer to the detailed pin definitions in the PDF manual (pages 20-24) for specific connections.

4. Operation
4.1. Device Activation
Before powering on the BMS, double-check that all balance cables are correctly connected and that the P- and B- terminals are properly wired. Ensure the protection board is securely mounted to the battery core. Once confirmed, the BMS can be activated.
The BMS is designed for charging activation mode: connect a charger with a voltage 2V higher than the battery voltage to activate the board. Alternatively, the BMS supports activation via a dedicated button or display screen if these accessories are connected.
4.2. Mobile APP Operation
The JIKONG BMS features a mobile application for Android (version 7 minimum) and iOS devices. The APP allows for real-time monitoring of battery status and modification of protection parameters.

To use the APP:
- Download the APP by scanning the QR code above.
- Connect your mobile device to the BMS via Bluetooth.
- Within the APP, you can view battery working status, modify protection parameters (e.g., overcharge/discharge voltages, currents, temperatures), and control charge/discharge switches.
4.3. Parameter Settings
Detailed instructions for setting various parameters, including equalization trigger differential pressure, protection thresholds, and communication protocols, are available in the comprehensive PDF manual provided by the manufacturer. You can access the PDF manual here: JIKONG V19 BMS User Manual (PDF).
4.4. Parallel Function Operation
The BMS supports parallel operation for monitoring up to 16 BMS units simultaneously via an upper computer (PC) using the RS485 bus. This requires a USB to RS485 serial port cable and JIKONG's PC software.
Setting up Parallel Communication:
- Assign a unique address (0-15) to each BMS using the DIP switches on the interface board. Address 0 is designated as the host, and addresses 1-15 are for slave units. Refer to the PDF manual (page 25) for DIP switch settings.
- Connect the host BMS (address 0) to the PC via a USB to RS485 serial port cable.
- Connect the RS485-2 ports of the BMS units in sequence using RJ45 Ethernet cables. The host BMS will have one RS485-2 port connected to the PC cable and the other to the first slave BMS.
- Open the JIKONG PC software, select the corresponding serial port, and click 'Connect' to monitor all connected BMS units.

5. Key Features
5.1. Active Equalization
The BMS employs an active equalization technology that transfers energy from higher-voltage cells to lower-voltage cells, ensuring uniform cell voltage across the battery pack. This process is critical for maximizing battery capacity and extending its lifespan. Users can configure equalization parameters, such as trigger differential pressure, via the mobile APP.

5.2. Heating Function
The BMS includes a standard heating function to prevent performance degradation in low-temperature environments. It uses a resistance heater or heating film to warm the battery, with a designed heating current of 10A. This function can be controlled via the mobile APP. For enhanced safety, it is recommended to install a normally closed temperature switch (45-65°C) in the heating circuit as a secondary protection.
5.3. Dry Contact Function
Two dry contacts are provided for controlling external devices such as alarms or cooling fans. When the BMS detects an over-temperature, overcharge, or over-discharge condition, these contacts can trigger an external alarm or activate a fan. Users can select two trigger conditions based on their specific needs.

5.4. Protection Functions
The BMS incorporates multiple protection mechanisms to safeguard the battery and system:
- Charge Overvoltage Protection: Prevents overcharging by shutting off charging when any cell exceeds the set voltage. Charging resumes when cell voltages drop below the recovery threshold.
- Discharge Undervoltage Protection: Prevents over-discharging by cutting off discharge when any cell falls below the set voltage. Discharge resumes when cells are charged above the recovery threshold. An automatic shutdown voltage is also configurable.
- Charge Overcurrent Protection: Limits charging current or stops charging if it exceeds the set continuous charge current for a specified delay.
- Discharge Overcurrent Protection: Stops discharge if the current exceeds the set continuous discharge current for a specified delay.
- Overtemperature Protection: Shuts down charging or discharging if battery temperature exceeds set limits. Operation resumes when temperature returns to safe levels.
- Low Temperature Protection: Stops charging if battery temperature falls below a set minimum to prevent damage. Charging resumes when temperature rises above the recovery threshold.
- Short Circuit Protection: Immediately cuts off current in case of a short circuit. Configurable delay and recovery times are available.
5.5. Emergency Switch
In critical situations (e.g., over-temperature, over-discharge, over-charge, or cell string drop), the emergency switch function can be activated via the APP. This allows the BMS to temporarily enable charge and discharge for 30 minutes, providing a window for emergency use, even if individual cell voltages have reached automatic shutdown levels.
5.6. Intelligent Sleep
To conserve energy, the BMS features an intelligent sleep mode. If the charging and discharging current remains below 1A for 26 consecutive hours, the BMS will enter a low-power state. It can be reactivated by pressing a button or connecting a charger.
5.7. Communication Functions
The BMS supports various communication protocols for integration with inverters and monitoring systems:
- CAN Communication: Default rate of 250K. Users can select specific inverter protocols via the APP.
- RS485 Communication: Two RS485 interfaces are available. RS485-1 is used for communication with inverters and other settings. RS485-2 is used for parallel connection of battery packs and communication with an upper computer (PC). The default baud rate is 115200.
- UART & RS232: Additional communication options for various applications.
5.8. Charge Current Limiting
When the battery experiences an overcurrent condition during charging, the BMS's current limiting function activates, regulating the charging current to approximately 10A to protect the battery.
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your JIKONG V19 BMS.
- Regular Checks: Periodically inspect all wiring connections for tightness and corrosion. Ensure the BMS unit is free from dust and debris.
- Software Updates: Keep the mobile APP and PC software updated to the latest versions to benefit from new features and bug fixes.
- Parameter Review: Occasionally review the BMS parameters in the APP to ensure they are still appropriate for your battery configuration and usage patterns.
- Temperature Monitoring: Pay attention to battery temperatures, especially in extreme conditions. Utilize the heating function in cold weather and ensure adequate cooling in hot environments.
7. Troubleshooting
This section addresses common issues and their potential solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| BMS not activating/powering on | Incorrect wiring (balance cables, P-/B-), charger voltage too low, loose connections. | Verify all wiring as per Section 3.3. Ensure charger voltage is at least 2V higher than battery voltage. Check for secure connections. |
| Frequent protection triggers (overcurrent, overvoltage, etc.) | Parameters set too low/high, faulty cells, excessive load/charge current. | Review and adjust protection parameters in the APP (Section 4.3). Inspect battery cells for health. Reduce load or charge current if possible. |
| Short circuit protection triggers unexpectedly | High peak current from charger/load, external wiring short. | Increase short circuit protection delay in APP. Verify external wiring for any shorts. |
| Battery imbalance persists | Active equalization not enabled, parameters incorrect, severely unbalanced cells. | Ensure active equalization is enabled in the APP. Check equalization parameters. Allow sufficient time for balancing. |
| Bluetooth connection issues | APP not updated, phone OS incompatible, distance too far. | Update APP to latest version. Ensure Android 7+ or compatible iOS. Reduce distance between phone and BMS. |
| Parallel communication failure | Incorrect DIP switch addresses, faulty RS485 cable, PC software issues. | Verify DIP switch settings for each BMS (Section 4.4). Check RS485 cable connections. Ensure PC software is correctly configured. |
8. User Tips
- Always perform a thorough visual inspection of all connections before applying power to the BMS.
- Utilize the mobile APP for real-time monitoring of individual cell voltages and overall battery health. This can help in early detection of potential issues.
- For optimal battery longevity, avoid consistently operating the battery at its extreme charge or discharge limits. Adjust protection parameters slightly within safe ranges if possible.
- In cold climates, remember to activate the heating function to maintain battery performance and prevent damage.
- When setting up multiple BMS units in parallel, double-check the DIP switch addresses to ensure each unit has a unique identifier.
9. Warranty and Support
For any technical assistance, warranty claims, or support inquiries, please contact Chengdu Jikong Technology Co. LTD, the manufacturer. Refer to your purchase documentation for specific warranty terms and contact information.