1. Introduction
The Grundfos UPA90/120 is an automatic, silent household booster pump designed to enhance water pressure and circulation for both cold and hot water systems. This pump is ideal for various applications, including boosting tap water pressure, improving water heater performance, and ensuring consistent water supply in high-rise buildings or homes with smart toilets and solar water heating systems. Its intelligent design ensures automatic operation, providing a comfortable and efficient water experience.

2. Key Features
- Automatic Start/Stop: Equipped with intelligent induction, the pump automatically starts when water flows and stops when the faucet is closed, eliminating manual operation.
- Silent Operation: Engineered for low noise, ensuring an undisturbed environment, even during nighttime use.
- High Performance: Delivers large flow and high lift, suitable for demanding household water pressure needs.
- Durable Construction: Features a full copper coil motor and ceramic bearings for extended lifespan and reliable performance.
- Versatile Application: Compatible with both cold and hot water systems (liquid temperature range +2°C to 95°C).
- Energy Efficient: Designed for safe and efficient operation.


3. Specifications
| Parameter | Value |
|---|---|
| Brand | Grundfos |
| Model | UPA 15-90, UPA 15-120 |
| Product Name | Fully automatic cold and hot water booster pump |
| Liquid Temperature Range | +2°C ~ 95°C |
| Maximum Flow | 2.2 m³/h |
| Maximum Lift | 12m |
| Power | 200W |
| Power Supply | 220V, 50Hz |
| Interface Distance | 200mm |
| Certification | CE |
| DIY Supplies Category | Electrical |
| Electronic Components | No |
| High-concerned chemical | None |
| Origin | Mainland China |
| Pump Drive Mode | Electric |

4. Installation
Proper installation is crucial for the optimal performance and longevity of your Grundfos UPA90/120 pump. It is recommended that installation be performed by a qualified professional.
4.1 Safety Precautions
- Ensure the main power supply is disconnected before beginning any installation work.
- Wear appropriate personal protective equipment (PPE).
- Verify that the installation site is dry and well-ventilated.
- The pump is designed for 220V, 50Hz power supply. Ensure your electrical system matches these requirements.
4.2 Mounting the Pump
- Choose a suitable location for the pump, ensuring it is easily accessible for maintenance and protected from extreme weather conditions.
- Mount the pump securely to a stable surface to minimize vibration and noise.
- Connect the pump in-line with your existing water piping system. Ensure the flow direction matches the arrows on the pump body. The pump has an interface distance of 200mm.
- Use appropriate pipe fittings and sealants to ensure watertight connections.
4.3 Electrical Connection
- Connect the pump's power cord to a grounded electrical outlet that meets the specified voltage and frequency (220V, 50Hz).
- Ensure all electrical connections are secure and protected from moisture.


5. Operation
The Grundfos UPA90/120 pump is designed for fully automatic operation based on water flow detection.
5.1 Initial Start-up
- After installation, ensure all connections are secure and there are no leaks.
- Open a faucet in your system to allow water to flow through the pump.
- Connect the pump to the power supply. The pump will automatically detect water flow and begin operation, boosting the pressure.
- Allow the pump to run for a few minutes to purge any air from the system.
5.2 Automatic Functionality
- When you open a water tap or appliance, the pump's intelligent flow sensor will detect the water movement and automatically start, providing boosted water pressure.
- When you close the water tap or appliance, the pump will detect the cessation of water flow and automatically shut down.

6. Maintenance
Regular maintenance helps ensure the long-term reliability and efficiency of your pump.
- Periodic Inspection: Regularly check the pump and connections for any signs of leaks, corrosion, or damage.
- Cleaning: Keep the exterior of the pump clean and free from dust and debris. Do not use harsh chemicals for cleaning.
- Winterization (if applicable): If the pump is installed in an area subject to freezing temperatures, ensure it is properly drained or protected to prevent damage from freezing water.
- Professional Check: Consider an annual check-up by a qualified technician to ensure all components are functioning correctly.
7. Troubleshooting
Before contacting support, please check the following common issues:
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start | No power supply; Faucet not open; Air in the system. | Check power connection and circuit breaker; Open a faucet to initiate water flow; Bleed air from the system. |
| Low water pressure | Insufficient incoming water supply; Clogged filter/pipes; Pump malfunction. | Check main water supply; Inspect and clean filters/pipes; Contact support if pump is faulty. |
| Pump runs continuously | Small leak in the system; Faulty flow sensor. | Check for and repair any leaks; Contact support for sensor inspection. |
| Unusual noise/vibration | Loose mounting; Air in the system; Internal component issue. | Securely fasten the pump; Bleed air; Contact support. |
8. Warranty and Support
This Grundfos UPA90/120 household booster pump comes with a two-year warranty from the date of purchase, covering manufacturing defects and material faults under normal use conditions.
For technical assistance, warranty claims, or any other inquiries, please contact the seller directly. You may reach support via WhatsApp at: +86 131 4214 4840.
Please retain your proof of purchase for warranty validation.