Grundfos UPA90/120

Grundfos UPA90/120 Household Booster Pump Instruction Manual

Model: UPA90/120 | Brand: Grundfos

1. Introduction

The Grundfos UPA90/120 is an automatic, silent household booster pump designed to enhance water pressure and circulation for both cold and hot water systems. This pump is ideal for various applications, including boosting tap water pressure, improving water heater performance, and ensuring consistent water supply in high-rise buildings or homes with smart toilets and solar water heating systems. Its intelligent design ensures automatic operation, providing a comfortable and efficient water experience.

Grundfos UPA90/120 Household Booster Pump
Figure 1: Grundfos UPA90/120 Household Booster Pump, main product view.

2. Key Features

  • Automatic Start/Stop: Equipped with intelligent induction, the pump automatically starts when water flows and stops when the faucet is closed, eliminating manual operation.
  • Silent Operation: Engineered for low noise, ensuring an undisturbed environment, even during nighttime use.
  • High Performance: Delivers large flow and high lift, suitable for demanding household water pressure needs.
  • Durable Construction: Features a full copper coil motor and ceramic bearings for extended lifespan and reliable performance.
  • Versatile Application: Compatible with both cold and hot water systems (liquid temperature range +2°C to 95°C).
  • Energy Efficient: Designed for safe and efficient operation.
Internal components and features of the pump
Figure 2: Illustration of pump's internal components and key features including high lift, copper motor, strong power, ample flow, automatic start/stop, and safe/efficient operation.
Noise level comparison of the pump
Figure 3: Noise level comparison, showing the pump operates quietly, comparable to falling leaves or a dripping clock, significantly quieter than indoor conversations or car horns.

3. Specifications

ParameterValue
BrandGrundfos
ModelUPA 15-90, UPA 15-120
Product NameFully automatic cold and hot water booster pump
Liquid Temperature Range+2°C ~ 95°C
Maximum Flow2.2 m³/h
Maximum Lift12m
Power200W
Power Supply220V, 50Hz
Interface Distance200mm
CertificationCE
DIY Supplies CategoryElectrical
Electronic ComponentsNo
High-concerned chemicalNone
OriginMainland China
Pump Drive ModeElectric
Product parameter table in Chinese
Figure 4: Product parameters table, confirming specifications such as liquid temperature, max flow, max lift, power, power supply, and interface distance.

4. Installation

Proper installation is crucial for the optimal performance and longevity of your Grundfos UPA90/120 pump. It is recommended that installation be performed by a qualified professional.

4.1 Safety Precautions

  • Ensure the main power supply is disconnected before beginning any installation work.
  • Wear appropriate personal protective equipment (PPE).
  • Verify that the installation site is dry and well-ventilated.
  • The pump is designed for 220V, 50Hz power supply. Ensure your electrical system matches these requirements.

4.2 Mounting the Pump

  1. Choose a suitable location for the pump, ensuring it is easily accessible for maintenance and protected from extreme weather conditions.
  2. Mount the pump securely to a stable surface to minimize vibration and noise.
  3. Connect the pump in-line with your existing water piping system. Ensure the flow direction matches the arrows on the pump body. The pump has an interface distance of 200mm.
  4. Use appropriate pipe fittings and sealants to ensure watertight connections.

4.3 Electrical Connection

  1. Connect the pump's power cord to a grounded electrical outlet that meets the specified voltage and frequency (220V, 50Hz).
  2. Ensure all electrical connections are secure and protected from moisture.
Grundfos UPA90/120 pump with power cord
Figure 5: The pump showing its integrated power cord and control unit.
Water flow comparison before and after pump installation
Figure 6: Visual comparison demonstrating improved water flow and pressure after the booster pump is installed, showing a significant difference in shower and faucet output.

5. Operation

The Grundfos UPA90/120 pump is designed for fully automatic operation based on water flow detection.

5.1 Initial Start-up

  1. After installation, ensure all connections are secure and there are no leaks.
  2. Open a faucet in your system to allow water to flow through the pump.
  3. Connect the pump to the power supply. The pump will automatically detect water flow and begin operation, boosting the pressure.
  4. Allow the pump to run for a few minutes to purge any air from the system.

5.2 Automatic Functionality

  • When you open a water tap or appliance, the pump's intelligent flow sensor will detect the water movement and automatically start, providing boosted water pressure.
  • When you close the water tap or appliance, the pump will detect the cessation of water flow and automatically shut down.
Automatic start/stop function illustration
Figure 7: Illustration of the pump's automatic start/stop function: it starts when water is turned on and stops when water is turned off.

6. Maintenance

Regular maintenance helps ensure the long-term reliability and efficiency of your pump.

  • Periodic Inspection: Regularly check the pump and connections for any signs of leaks, corrosion, or damage.
  • Cleaning: Keep the exterior of the pump clean and free from dust and debris. Do not use harsh chemicals for cleaning.
  • Winterization (if applicable): If the pump is installed in an area subject to freezing temperatures, ensure it is properly drained or protected to prevent damage from freezing water.
  • Professional Check: Consider an annual check-up by a qualified technician to ensure all components are functioning correctly.

7. Troubleshooting

Before contacting support, please check the following common issues:

ProblemPossible CauseSolution
Pump does not startNo power supply; Faucet not open; Air in the system.Check power connection and circuit breaker; Open a faucet to initiate water flow; Bleed air from the system.
Low water pressureInsufficient incoming water supply; Clogged filter/pipes; Pump malfunction.Check main water supply; Inspect and clean filters/pipes; Contact support if pump is faulty.
Pump runs continuouslySmall leak in the system; Faulty flow sensor.Check for and repair any leaks; Contact support for sensor inspection.
Unusual noise/vibrationLoose mounting; Air in the system; Internal component issue.Securely fasten the pump; Bleed air; Contact support.

8. Warranty and Support

This Grundfos UPA90/120 household booster pump comes with a two-year warranty from the date of purchase, covering manufacturing defects and material faults under normal use conditions.

For technical assistance, warranty claims, or any other inquiries, please contact the seller directly. You may reach support via WhatsApp at: +86 131 4214 4840.

Please retain your proof of purchase for warranty validation.

Related Documents - UPA90/120

Preview Grundfos UPM3(K) AUTO Circulation Pump - Installation and Operation Instructions
Comprehensive instructions for the Grundfos UPM3(K) AUTO high-efficiency circulation pump, covering installation, operation, technical specifications, and safety guidelines.
Preview Grundfos CM Booster PS, PT Installation and Operating Instructions Supplement
This document provides supplementary installation and operating instructions for the Grundfos CM Booster PS and PT pump systems. It covers essential information on applications, system sizing, mechanical and electrical installation, start-up procedures, adjustment of pressure settings, operation, maintenance, technical data, and troubleshooting common faults. It also includes the EC Declaration of Conformity and a list of Grundfos company worldwide contacts.
Preview Grundfos SCALA Multistage Centrifugal Boosters Data Booklet
This data booklet provides comprehensive information on Grundfos SCALA multistage centrifugal boosters, including product ranges, installation, operation, selection guides, technical data, and accessories for SCALA1 and SCALA2 models.
Preview Grundfos MI 301 : Guide d'installation et de fonctionnement
Ce document fournit des instructions essentielles pour l'installation et le fonctionnement de l'interface mobile Grundfos MI 301. Il détaille les caractéristiques du produit, les options de connectivité via Bluetooth, radio et infrarouge, et propose des conseils de dépannage pour une intégration transparente avec les équipements Grundfos.
Preview Grundfos SCALA Multistage Centrifugal Boosters Data Booklet
This data booklet provides comprehensive information on the Grundfos SCALA range of multistage centrifugal booster pumps, including SCALA1 and SCALA2 models. It covers product introduction, selection guides, installation and operation details, technical data, performance curves, accessories, and product numbers. The SCALA series is designed for domestic and light commercial water supply applications, offering features like self-priming, dry-run protection, and easy installation.
Preview Grundfos MI 301: Installation and Operating Instructions
This document provides installation and operating instructions for the Grundfos MI 301 mobile interface. Learn how to connect, control, and maintain Grundfos pumps remotely using the Grundfos GO Remote app.