vilnason L7

Contents

Red Light Therapy Pad L7 User Manual

Model: L7

Brand: vilnason

1. Introduction

The L7 Light Therapy Pad utilizes thermal and photochemical reactions through infrared light therapy and visible light therapy (LLLT). This non-invasive, non-toxic device delivers beneficial light energy to tissues and cells, similar to how plants absorb sunlight for growth. It is designed to provide targeted support for various pain areas and rehabilitation needs, effectively promoting wound healing, reducing inflammation, and restoring vitality.

2. Safety Information

General Warnings and Cautions

  • If the product is damaged during transport, do not attempt to handle it as it may put you in danger. Please contact customer service for advice before trying to connect and turn on the damaged product.
  • Do not modify, disassemble, or repair this product by yourself. Failure to follow this precaution may result in an electric shock.
  • Health care providers and users should avoid looking directly at light sources. It is recommended to wear goggles or use other appropriate eye protection.
  • Do not look directly at any of the light-emitters inside the device.
  • Do not immerse the product in water or any liquid.
  • Do not use this product near strong electromagnetic radiation sources.
  • Please do not place this product near heat sources, such as radiators, heaters, furnaces, or other hot objects.
  • Protect the power cable from being trampled or squeezed.
  • Please unplug the device during thunderstorms or when it will not be used for a long time.
  • Do not fold or over-curl the product. When using or storing, the inward or outward curvature of the product shall not be less than 2 inches in diameter.
  • This product is not intended to be used as a toy. Exercise caution when around children and ensure they do not play with or misuse the product. Please supervise children to prevent any unauthorized use.
  • If you feel any discomfort, please stop using this product immediately and contact a doctor.

Contraindications

Do not use the device under the following conditions:

  • On pregnant or lactating women.
  • On infants or children.
  • If you are currently taking steroids or receiving cortisone injections.
  • If you have photoallergy or are taking photosensitizing drugs (such as tetracycline).
  • On patients with malignant tumors.
  • If you have thrombosis or venous disease.
  • If you have a pacemaker.
  • On areas with skin ulceration.
  • On patients with epilepsy or seizure disorders.
  • If you have been diagnosed with bipolar disorder or other conditions that may be adversely affected by light exposure.

3. Setup

Package Contents

  • 1x Red Light Therapy Pad
  • 1x Adapter
  • 1x User Manual
  • 1x Elastic Strap
Components of the Red Light Therapy Pad L7, including the pad, power adapter, elastic strap, and user manual.
Figure 1: Package contents of the L7 Red Light Therapy Pad.

Product Structure

The L7 therapy pad features a flexible design with LED chips on one side and a skin-friendly spandex lining on the other. The control panel is integrated into the power cable for easy access.

Close-up of the ultra skin-friendly spandex lining, highlighting soft, breathable, hypoallergenic properties. Also shows the honeycomb design and power connection.
Figure 2: Ultra skin-friendly spandex lining and honeycomb design for safety.

Pre-Use Preparation

  1. Select the target skin area, ensuring it is clean, dry, and free of sunscreen or skincare products, as certain minerals in these may reflect light and reduce energy absorption.
  2. For best results, wear the red light pad directly on bare skin or over light-colored, thin fabric. Avoid dark clothing, which can limit light penetration.

4. Operating Instructions

How to Use

  1. Insert the power adapter's TYPE-C plug into the product's power port, then plug the adapter into the power outlet.
  2. Press and hold the On/Off button on the control panel for 2 seconds to turn on the device.
  3. Briefly press the Mode (M) button to select desired light modes and start treatment.
  4. Briefly press the Power button to adjust power levels (brightness) in the current mode.
  5. After the 30-minute therapy session, the device will emit 5 beeps to indicate completion and automatically shut off.
Control panel with Power Button/Adjust Power Levels and Mode Switch, showing 4 Light Modes, 30 Mins Auto-off time, 3 Level Brightness.
Figure 3: Control panel for adjusting modes and power levels.

Application Areas

The therapy pad is suitable for use on various body parts including the back, waist, legs, arms, shoulders, and knees. Simply relax for 10-30 minutes while the warming red light penetrates your skin for optimal therapeutic effects.

Four images showing full body use with an adjustable strap on various body parts (thighs, waist, arm, chest).
Figure 4: Examples of full-body application with the adjustable strap.

Light Modes and Brightness Levels

  • 4 Working Light Modes:
    1. Relieve Pain: Red light (660nm) + Infrared (850nm)
    2. Heal Wounds: Red light (660nm)
    3. Recover Energy: Red light (660nm) + Infrared (850nm) + Pulsed (10Hz)
    4. Reduce Inflammation: Red light (660nm) + Infrared (850nm) + Pulsed (40Hz)
  • 3 Brightness Levels:
    1. L1: Mild warming
    2. L2: Balanced therapy
    3. L3: Deep penetration

The device features a 30-minute auto-shutoff function for your safety. Simply restart to continue treatment if desired.

5. Maintenance

Cleaning and Storage

  1. Unplug the Device: Always disconnect the power plug from the electrical outlet before cleaning to ensure safety.
  2. Wipe with a damp cloth: Clean the device using a moistened cloth, then store it properly after drying.
  3. Avoid volatile solvents: Do not use volatile solvents (e.g., alcohol), harsh chemicals, or cleaning agents, as they may damage the product.

Keep the device dry. This product is not sealed and cannot be used outdoors or in wet places.

6. Troubleshooting

Common Issues and Solutions

  • Device automatically shuts off after 30 minutes: This is a normal safety feature. The device is designed with a 30-minute auto-shutoff function and will emit five beeps to indicate completion. This is not a malfunction; you can restart the device to continue treatment if needed.
  • Device not turning on: Ensure the power adapter is securely plugged into both the device's TYPE-C port and a functional power outlet. Check for any visible damage to the power cable or adapter.
  • Reduced light intensity or uneven light: Ensure the pad is clean and free from any obstructions. If the issue persists, contact customer service.

7. Specifications

FeatureDetail
Product NameRed Light Pad for Body
Product ModelL7
Input VoltageDC 24V (Below-50V AC, SELV AC)
Rated Current1.5A
Rated Power36W
Light Irradiance90mW/cm²
Red Light Wavelength660nm ±5nm
Near-Infrared Wavelength850nm ±5nm
Red LEDs Quantity264 pcs
Near-Infrared LEDs Quantity528 pcs
Total LED Quantity792 pcs
Power Levels3 (L1, L2, L3)
Working Light ModesRed+Infrared, Pure Red, 10Hz Pulse, 40Hz Pulse
Default Timing30 minutes (Auto-shutoff)
Product Dimensions76.5 x 30.5 cm (approx. 30 x 12 inches)
Net Weight0.3 kg
Gross Weight0.8 kg
MaterialPlastic, Medical spandex + ice silk lycra + breathable leather
Manufacturing ProcessMachine Made
CertificationCE
Working PrincipleOthers (Light Therapy)
Power SourceElectric (Plug into household power outlet)
Batteries IncludedNo
Working EnvironmentTemperature 0°C to 35°C, Relative Humidity 10% to 80% (non-condensing)
Transportation ConditionsTemperature -20°C to 50°C, Relative Humidity 20% to 85% (non-condensing)
Diagram showing 792 LED chips (660nm red, 850nm infrared) and their penetration depth into skin layers.
Figure 5: LED chip configuration and light penetration depth.
Certificate of Conformity (CE) for the Light Therapy System, listing model numbers and applied standards.
Figure 6: CE Certificate of Conformity.

8. User Tips

  • For optimal results, ensure the skin area is clean, dry, and free of any lotions or sunscreens before use.
  • Wear the pad directly on bare skin or over light-colored, thin clothing to maximize light penetration. Avoid dark fabrics.
  • Many users report superior comfort due to the medical spandex, ice silk lycra, and breathable leather construction.
  • Consistent daily use for 30 minutes has shown pain reduction for many users within 3 weeks.
  • The large 30"x12" size and included 47" adjustable strap allow for flexible application on various body parts, including the back, hips, waist, shoulders, legs, knees, and feet.
  • The device's auto-memory function for the last settings and the 30-minute timer enhance convenience for regular therapy sessions.

9. Warranty and Support

Warranty Terms

The product warranty (covering free repairs) is valid from the date of purchase until the end of the warranty period. Repairs are only available through official stores. Proof of purchase must be provided for any maintenance or repair service.

Unauthorized disassembly, modification, or improper use of this product is strictly prohibited. If the product has been disassembled, the warranty service will be immediately voided.

Necessary repairs resulting from normal use are covered under a 12-month warranty from the date of purchase. However, if any of the following conditions apply, the warranty may be voided during the warranty period. Damage caused by improper use will invalidate the warranty, though the equipment may still be repaired at an additional cost.

Conditions that void the warranty include:

  • Product damage caused by violation of the product manual instructions.
  • Product damage caused by using unauthorized accessories (such as chargers).
  • Product damage caused by operation outside specified environmental conditions (such as high temperatures or corrosive environments).
  • Product damage caused by abnormal external forces (such as drops, crushing, or impacts).
  • Product damage caused by natural disasters or other force majeure events (such as fires, floods, or earthquakes).
  • Failure to provide valid proof of purchase, including purchase records or invoices.
  • Damage to products or components caused by external unforeseen factors or user misuse.

Additional Support

For further assistance or if you are unfamiliar with the English manual, please contact customer service to request an electronic version of the manual. A PDF version of the user manual is available for download here.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.