Introduction
This manual provides detailed instructions for the safe and efficient operation of your ETENWOLF S0 Cordless Air Pump. Please read all instructions and safety warnings carefully before use to ensure proper functionality and to prevent damage or injury.
The ETENWOLF S0 is a compact and portable digital air pump designed for rapid inflation of various items, including bicycle tires, car tires, and sports balls. It features a digital display, a powerful brushless motor, and a 2400mAh battery for cordless convenience.
Package Contents
Ensure all items are present in the package:
Image: Contents of the ETENWOLF S0 package.
- 1x ETENWOLF S0 Mini Bicycle Pump
- 1x Air Chuck (T-shaped quick connector)
- 1x User Manual
- 1x Cone shaped nozzle
- 1x Ball needle
- 1x French copper adapter
Product Overview
Familiarize yourself with the components of your ETENWOLF S0 air pump:
Image: Labeled components of the ETENWOLF S0 air pump.
- Power On/Off Button
- "+" Pressure Increase Button
- "-" Pressure Decrease Button
- High-pressure Hose
- Target Input/Actual Pressure Display
- Battery Indicator
- Pressure Unit (PSI/BAR)
- Type-C Port
Note: The power-on screen shows the target input value for 2 seconds, then displays the actual pressure.
Setup
Charging the Battery
For optimal performance, fully charge the pump before its first use. Use a certified PD charger and the included Type-C cable.
- Charging from 0% to 100% takes approximately 1-2 hours.
- Battery Indicator (Charging):
- 0-20% Orange light blinking
- 20-99% White light blinking
- 100% White light solid
Note: The pump will automatically shut down after 5 minutes of inactivity when fully charged. It cannot be used while charging.
Pressure Calibration
Different altitudes can cause pressure variations. In high-altitude areas (above 5000 ft / 1524 m), recalibration of the sensor may be necessary.
Calibration Steps:
- Press the Power On/Off button to turn on the device.
- Hold both the "+" and "-" buttons simultaneously for 5 seconds.
- When the display blinks, calibration is successful.
Important Notes for Calibration:
- The device must be turned on before starting calibration.
- The high-pressure hose must not be connected to anything during calibration, or it will fail.
- Sufficient battery power or an external power source is required for calibration.
- Calibration settings are not saved; the device resets to sea level (0 ft/m) when powered off.
- Above 5000 ft / 1524 m, manual calibration is required each time the pump is turned on.
Operating Instructions
Quick Start Guide for Inflation
Image: Quick start guide for inflation.
- Screw the nozzle end of the high-pressure hose clockwise into the valve of the item to be inflated.
- Press the Power On/Off button to turn on the pump.
- Press the "+" and "-" buttons together to switch between PSI and BAR pressure units.
- Use the "+" and "-" buttons to adjust the desired pressure value.
- Press the Power On/Off button again to start the inflation process.
- The pump will automatically stop once the preset pressure is reached.
Checking the Current Pressure Value
- Connect the nozzle end of the high-pressure hose to the item you wish to measure.
- Press the Power On/Off button to turn on the pump.
- The digital screen will display the current pressure value of the connected item.
Power On/Off and Pause Function
- Turn On: Long press the Power On/Off button for 0.5 seconds.
- Turn Off: When the pump is on, long press the Power On/Off button for 2 seconds.
- Pause: During inflation, press the Power On/Off button again at any time to pause.
Automatic Shut-off Conditions:
The pump will automatically shut off in the following cases:
- The charging cable is accidentally disconnected.
- The battery runs out.
- After 5 minutes of inactivity following a full charge.
Preset Pressure Value and Memory
The screen displays both the target and actual pressure values. The default preset pressure is 22 PSI, which can be adjusted using the "+" and "-" buttons.
Each time you adjust the pressure, the system will remember your new target pressure and unit. You can change this default setting at any time.
Versatile Applications
The ETENWOLF S0 is suitable for inflating a wide range of items:
Image: Examples of items that can be inflated with the ETENWOLF S0.
- Motorcycle tires
- Mountain bike tires
- City bike tires
- Basketballs, Volleyballs, Footballs, Rugby balls
- Swim rings, Balloons
Maintenance
- Always use the product in a dry, clean environment to prevent dust intrusion from damaging the product.
- Do not clean the product with water.
- Store the product within the recommended temperature range of -4°F to 140°F (-20°C to 60°C). Extreme temperatures can damage the battery and shorten the pump's lifespan.
- For long-term storage, charge the pump at least once every three months to maintain optimal battery efficiency and performance.
- Keep the product away from heat sources and avoid leaving it in a hot car for extended periods, as overheating can pose a risk of explosion.
Troubleshooting
| Problem | Solution |
|---|---|
| Inflation is slow | Check for leaks in the hose; ensure battery is charged. |
| Pump is on but not inflating | Check if target pressure exceeds preset value. |
| Battery indicator doesn't show after charging | Use certified PD charger and try again. |
| Pump stopped due to extreme temperature | While charging, temperature must be 0°C-45°C (32°F-113°F). While inflating/deflating, temperature must be -20°C–74°C (-4°F–165°F). |
| Safety alert symbol lights up if abnormal pressure or motor error | Turn off the unit and restart after 10 minutes. |
| Pump is working but pressure reads zero | If pressure <3 PSI, display shows 0 due to sensor limits. |
| Battery indicator varies from standby during use. | Lithium battery voltage drops under load, causing this; it's normal. |
| Safety symbol shows E08 | If issue persists after reboot, contact factory for repair. |
| Displays error code E10 | Motor failure warning. May recover after blinking 30 sec. If not, send for repair. |
| Displays error code E11 | Low-temp charge icon: charging temp too low. Warm to above 0°C before charging. |
| Displays error code E12 | High-temp charge icon: let temp drop below 45°C before charging. |
| Displays error code E13 | Low-temp discharge icon: warm to >-20°C before use or charging others. |
| Displays error code E14 | High-temp discharge icon: cool below 58°C before use or output charging. |
| Display error code E15 | The air pump has exceeded the working time, the warning icon flashes for 30 seconds then returns to normal. Check if the inflated item is leaking. |
| Display error code E16 | Overpressure protection icon, returns to normal after releasing pressure. |
| Display error code E17 | High-pressure operation has exceeded working time, warning icon flashes for 30 seconds then returns to normal. Check if the inflated parts are functioning abnormally. |
| Display error code E18 | Battery damage warning icon and battery level indicator icon flash. After 30 seconds, the device will shut down. It is necessary to send the device to the factory. |
Specifications
| Name | Bicycle Pump |
|---|---|
| Model | S0 |
| Size | 94.8 x 75.2 x 40.2 mm |
| Inflation pressure range | 3.0-150.0 PSI / 0.20-10.34 bar |
| Operating temperature | Charging: 32°F~113°F (0°C~45°C), Discharging: -4°F~165°F (-20°C~74°C) |
| Storage temperature | -4°F~140°F (-20°C~60°C) |
| High-pressure hose length | 88 mm |
| Battery capacity | 2400 mAh (8.88 Wh) |
| Operating noise | Below 85 dB within 1 meter range |
| Input | Type-C: 5V 2A |
| Working duration | About 15 minutes at 25°C ambient temperature, within 20-50 PSI inflation pressure range |
| Charging time | 1-2 Hours |
| Sensor accuracy | ±1 psi |
Safety Instructions
- This product is not a toy and is not suitable for children. Users must be at least 16 years old. Keep children at a safe distance from the pump during inflation.
- The product contains a built-in lithium battery. Do not throw the product into fire or dispose of the battery improperly.
- Overheating damage or water ingress may increase the risk of fire or explosion. It is best to keep the product away from heat sources and not leave it in a hot car for long periods. If the pump becomes very hot, it may explode.
- Please store the product within the temperature range of -4°F to 140°F (-20°C to 60°C). Extremely hot or cold environments can damage the battery and shorten the pump's lifespan. Long-term storage can reduce battery efficiency. Charge the pump at least once every three months to maintain good performance.
- This product contains a built-in DC motor, which may produce sparks during use. Do not use in environments with explosive dust or gas.
- If there is unusual noise or the temperature becomes very high during inflation, please turn off the pump immediately.
- Before setting the inflation pressure, please ensure the correct pressure unit (PSI or BAR) is selected. Mixing PSI and BAR may cause over-inflation and explosion. (Unit conversion: 1 bar = 14.5 psi, 1 bar = 100 kPa).
- Do not leave the pump unattended while operating.
- Use this product in a dry, clean environment. Dust intrusion may damage the product. Do not clean the product with water.
- Always use a certified PD charger and the included charging cable to charge this product.
- To reduce the risk of electric shock, do not expose the device to rain; store it indoors. Failures caused by not following these requirements are not covered by the warranty.
User Tips
- To stop inflation at any time, simply press the power button.
- The pump remembers your last used pressure setting, making repeated tasks quicker.
- Always double-check your target pressure setting before inflating to prevent over-inflation.
- After inflating, the internal tire temperature may drop, causing a slight pressure reduction (0.5-1.5 psi). This is normal.
- When inflating bicycle tires, quickly remove the hose after inflation to minimize air leakage.
Warranty & Support
Your ETENWOLF S0 Cordless Air Pump comes with a two-year warranty from the date of purchase. During this period, we provide timely and effective online after-sales service.
We will repair or replace any defective product (due to manufacturing faults) within the warranty period.
Contact Information:
- Phone Support: (1)877-838-0209 (Mon-Fri 8AM-5PM PST)
- Email Support: support@etenwolf.com
- Website: www.etenwolf.com
- Facebook: www.facebook.com/etenwolftools
Manufacturer: Guangdong Bestek Technology Co., Ltd
Address: No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R.China
Brand owner: Mozhen Technology (Shenzhen) Co., LTD
Address: CN-503, Floor 5, Building 4, Tianan Yungu Industrial Park Phase II, Gangtou Community, Bantian Street, Longgang District, Shenzhen, Guangdong, CN
Additional Resources:
A detailed user manual is available in PDF format for download: ETENWOLF S0 User Manual (PDF)