1. Introduction
Thank you for purchasing the HITBOX HIM200 Inverter Welder. This manual provides detailed instructions for the proper operation, installation, maintenance, and troubleshooting of your welding machine. Please read it carefully before use and keep it for future reference.
The HIM200 is designed according to national and international standards (GB/T15579-1, IEC60947, EN60947, AS60947, UL60947) and conforms to EMC requirements. The design and manufacturing technology are patented.
2. Safety Precautions
Welding is dangerous and can cause harm to you and others, so protect yourself when welding. For more information, consult the Operator Safety Guide for Compliance with Manufacturer Accident Prevention Requirements.
2.1 Professional Training Required
- Only operate the machine after receiving professional training.
- Use labor protection welding supplies authorized by the state security department.
- Operators must possess a valid "Metal Welding (OFC) Operation" certificate.
- Always cut off the power before performing maintenance or repair.
2.2 Electrical Safety
- Never touch a charged area with bare skin or while wearing wet gloves/clothing.
- Ensure you are insulated from the ground and workpiece.
- Verify your work location is safe.
2.3 Fumes and Gases
- Keep your head away from smoke and gases to avoid inhaling exhaust fumes from welding.
- When welding, use exhaust or ventilation equipment to keep the working environment well ventilated.
2.4 Eye and Body Protection
- Wear a comfortable welding mask and protective clothing to protect your eyes and body.
- Use a suitable mask or screen to protect others from harm.
2.5 Fire and Explosion Hazards
- Welding sparks can start a fire. Ensure there are no combustible materials nearby and be aware of fire hazards.
- Keep fire extinguishers nearby and ensure personnel are trained to use them.
- Container welding is strictly prohibited.
- Do not use these machines for powder spray thawing.
2.6 High Temperature Surfaces
- Hot workpieces can cause severe burns. Avoid direct contact with hot surfaces.
- The torch requires cooling during continuous use.
2.7 Magnetic Fields and Pacemakers
- Pacemaker users should stay away from the solder joint and seek medical attention if concerned.
2.8 Moving Parts
- Keep away from moving parts such as fans.
- During operation, all doors, panels, lids, and other protective devices must be closed.
2.9 Machine Failure
In case of machine failure, seek professional help. If difficulties arise during installation or operation, please consult the relevant sections of this manual. If issues persist, contact your supplier's service center.
3. Product Overview
The HITBOX HIM200 is a versatile 4-in-1 multi-process synergic welder supporting MIG (Gasless Flux MIG), MMA (Stick/ARC), Lift TIG, and Spool Gun (requires separate purchase) welding modes. It features an IGBT power supply unit for enhanced reliability and high duty cycle for extended welding times.
Key features include closed-loop feedback control, adjustable welding voltage and current, stable arc characteristics, minimal spatter, and beautiful weld beads. The high-frequency design reduces size and weight, improves welding efficiency, and eliminates noise pollution.


4. Panel Description
4.1 Front Panel

- Digital LCD screen
- Mode button
- Function button
- Rotate and confirm knob
- "+" Pole (Positive output)
- 4-Pin Socket (for Spool Gun)
- "-" Pole (Negative terminal)
- Power Switch (on back panel, but listed here as a control point)
- Fan (on back panel, but listed here as a control point)
Note: The OCR text for the front panel was slightly ambiguous, so I've used the image labels for clarity.


4.2 Back Panel

- Power cord input (AC110/220V)
- Power switch (ON/OFF)
5. Setup and Installation
Note: Always turn off the power switch before making any electrical or electronic connections. This machine has an IP21S protection rating; avoid using it in the rain.
5.1 Connection of Input Cables
- Connect the main power cable to the rated input power supply. Grounding connections are required for security.
- Ensure the primary cable is tightly connected to the correct socket to avoid oxidation.
- Check the voltage value with a multimeter to ensure it is within an acceptable range.
5.2 MMA (Stick/ARC) Installation
- The welding machine has two quick plugs. Plug the quick plug into the quick plug on the front panel and tighten it for good contact. Poor contact can lead to burning if working time is long or current is high.
- Plug the cable with the electrode holder into the "+" socket on the front panel and tighten it clockwise.
- Plug the cable with the work clamp into the "-" socket on the front panel and tighten it clockwise.
- DCEP (Direct Current Electrode Positive) and DCEN (Direct Current Electrode Negative) connections are available in MMA mode.
- DCEP: Connect the electrode holder to the "+" output terminal and the work fixture to the "-" output terminal.
- DCEN: Connect the electrode holder to the "-" output terminal and the work fixture to the "+" output.
- If the secondary cable (welded and grounded) is long, use a cable with a larger cross-section to reduce voltage drop.
5.3 MIG (Flux Core) Installation
- Connect the main power cable. Grounding connections are required for security.
- Plug the quick plug on the wire feeder into the "+" socket on the front panel and tighten it clockwise.
- Plug the cable with the work clamp into the "-" socket on the front panel and tighten it clockwise.
- Install the torch and mount the spool on the rotating shaft. Ensure the groove dimensions at the feed position on the drive roller match the contact tip size of the torch and the wire used.
- Insert the aviation plug of the wire feeder into the aviation socket on the front panel and press the wire snap button to feed the wire out of the torch head.
- Connect the wire feeder to the flow regulator on the cylinder with a tubing (if using gas MIG).

5.4 Lift TIG Installation
- Connect the TIG torch (additional purchase) to the negative terminal.
- Connect the ground clamp to the positive terminal.
- If using gas, connect the hose from the TIG torch to the Argon gas cylinder via a flow regulator.
5.5 Spool Gun Installation (Optional)
The HIM200 supports a spool gun (requires additional purchase). Ensure the spool gun is connected correctly to the designated 4-pin socket on the front panel, and the ground clamp is connected to the positive terminal.
6. Operating Instructions
6.1 General Operation
- After completing the installation, turn on the air switch on the back panel. The power LED will light up, and the fan will start.
- If using gas, open the cylinder valve and turn the gas check switch to "gas check" position. Adjust the flow regulator for the appropriate gas flow.
- Adjust the inductance control knob to achieve the desired arc. Rotate counter-clockwise for lower inductance and harder arcs; rotate clockwise for higher inductance and softer arcs. Harder arcs are generally selected at lower currents, and softer arcs at higher currents.
- Select the appropriate welding voltage and current by adjusting the current control knob and voltage control knob on the wire feeder.
- The gas supply is cut off 1 second after the arc stops.
6.2 Welding Programs and Parameters
6.2.1 Current Setting (Short-Circuit Transition)
The welding current is set after preparation. Short-circuit conversion is suitable for thin electrodes, low voltage, and low current, ensuring stable welding with less splash and beautiful weld beads.
| Electrode φ (mm) | Applicable Current (A) | Optimum Current (A) |
|---|---|---|
| 0.8 | 50~120 | 70~100 |
| 1.0 | 70~180 | 80~120 |
| 1.2 | 80~350 | 100~200 |
| 1.6 | 140~500 | 140~350 |
6.2.2 Welding Speed Selection
Welding quality and productivity depend on welding speed. Increased speed can weaken protection and speed up cooling, affecting weld molding. If speed is too slow, the workpiece may burn through. Optimal welding speed should not exceed 50cm/min.
6.2.3 Electrode Extension
Increased elongation can boost productivity, but excessive elongation leads to spattering, wire breakage, and unstable welding. Generally, the extension should be 10 times the electrode diameter.
6.2.4 Protective Gas Flow Selection
Protective effect is a primary consideration. Inner fillet welding has better protection than outer fillet welding, requiring less airflow. Less or no shielding gas is needed for FCAW (Flux-Cored Arc Welding).
| Welding Method | W-type Weld Wire (Thin) | Welded with Coarse Wire | Welded with Thick Wire (High Currents) |
|---|---|---|---|
| Gas Flow (l/min) | 5~15 | 15~20 | 20~25 |
6.2.5 Welding Parameter Tables (Reference Only)
Welding current and voltage directly affect stability, quality, and productivity. Optimal settings depend on electrode diameter, metal transfer method, and production requirements.
Type I Butt Weld Parameters
| Plate Thickness t (mm) | Gap g (mm) | Electrode mm | Welding Current (A) | Welding Voltage (V) | Welding Speed (cm/min) | Gas Flow (l/min) | Layer |
|---|---|---|---|---|---|---|---|
| 1.2 | 0 | 1.0 | 70-80 | 17-18 | 45-55 | 10 | 1 |
| 1.6 | 0 | 1.0 | 80-100 | 18-19 | 45-55 | 10-15 | 1 |
Flat Angle Welding Parameters
| Plate Thickness t (mm) | Corn Size l (mm) | Electrode mm | Welding Current (A) | Welding Voltage (V) | Welding Speed (cm/min) | Gas Flow (l/min) |
|---|---|---|---|---|---|---|
| 1.2 | 2.5-3.0 | 1.0 | 70-100 | 18-19 | 50-60 | 10-15 |
| 1.6 | 2.5-3.0 | 1.0-1.2 | 90-120 | 18-20 | 50-60 | 10-15 |
| 2.0 | 3.0-3.5 | 1.0-1.2 | 100-130 | 19-20 | 50-60 | 10-20 |
| 2.3 | 3.0-3.5 | 1.0-1.2 | 120-140 | 19-21 | 50-60 | 10-20 |
| 3.2 | 3.0-4.0 | 1.0-1.2 | 130-170 | 19-21 | 45-55 | 10-20 |
| 4.5 | 4.0-4.5 | 1.2 | 190-230 | 22-24 | 45-55 | 10-20 |
Fillet Weld Parameters in Vertical Position
| Plate Thickness t (mm) | Corn Size l (mm) | Electrode mm | Welding Current (A) | Welding Voltage (V) | Welding Speed (cm/min) | Gas Flow (l/min) |
|---|---|---|---|---|---|---|
| 1.2 | 2.5-3.0 | 1.0 | 70-100 | 18-19 | 50-60 | 10-15 |
| 1.6 | 2.5-3.0 | 1.0-1.2 | 90-120 | 18-20 | 50-60 | 10-15 |
| 2.0 | 3.0-3.5 | 1.0-1.2 | 100-130 | 19-20 | 50-60 | 10-20 |
| 2.3 | 3.0-3.5 | 1.0-1.2 | 120-140 | 19-21 | 50-60 | 10-20 |
| 3.2 | 3.0-4.0 | 1.0-1.2 | 130-170 | 22-22 | 45-55 | 10-20 |
| 4.5 | 4.0-4.5 | 1.2 | 200-250 | 23-26 | 45-55 | 10-20 |
For MIG welding with Ar+CO2 gas mixture (10 to 15 l/min) on carbon steel, refer to the table above for parameters.
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your welding machine.
- Periodically check internal circuit connections (especially plugs). Tighten any loose connections. If oxidation is present, remove it with sandpaper and reconnect.
- Keep hands, hair, and tools away from moving parts such as fans to avoid personal injury or damage.
- Clean the dust regularly with dry, clean compressed air. If the welding environment is smoky or polluted, the machine should be cleaned daily. The compressed air pressure should be appropriate to avoid damaging small internal parts.
- Avoid rain, water, and vapor infiltration. If the machine gets wet, dry it thoroughly and check the insulation of the equipment (between connections and housing). The machine can only be used once the anomaly is no longer present.
- Periodically check that the insulation cover of all cables is in good condition. Replace any worn or damaged parts.
- Regularly check the trachea for cracks and replace if necessary.
- If unused for a long time, store the machine in a dry place in its original packaging.
8. Troubleshooting
Warning: The following operations require sufficient electrical expertise and comprehensive safety knowledge. Operators should hold a valid qualification. Before working on the welding machine, ensure the machine's input cable has been disconnected from the power utility.
| Symptom | Check the Steps |
|---|---|
| The overheating LED is on. |
|
| No response when pressing the gun trigger, protection LED is off. |
|
| Wire feeder sends wire into gas when pushing trigger, but no output current and protection LED is off. |
|
| Output current when pushing gun trigger into air, but wire feeder does not send wire. |
|
| Welding can be performed when torch trigger is pressed, but voltage cannot be adjusted. No-load voltage is too high. |
|
| Welding current is unstable. |
|
| The weld is not well protected. |
|
| There is a large pit after welding. |
|
9. Specifications
| Parameter | HIM200 (110/220V) | HIM200 (220V) |
|---|---|---|
| Input Voltage (V) | AC 110/220V ± 15%, 50/60Hz | AC 220V ± 15%, 50/60H |
| Rated Input Current (A) | AC 110V 40A / AC 220V 20A | AC220V 20A |
| Rated Input Capacity (KVA) | 4.5 | 4.5 |
| Recommended Fuse Capacity (A) | 30 | 30 |
| MMA Weld Current Range (A) | 10~120 | 10~120 |
| MIG Welding Current Range (A) | 20~120 | 20~120 |
| MIG Voltage Range (V) | 11~20 | 11~20 |
| No-load Voltage (V) | 55 | 55 |
| Wire Feeding Speed Range (m/min) | 1.5~16 | 1.5~16 |
| Applicable Wire Diameter (mm) | 0.6/0.8 | 0.6/0.8 |
| Rated Duty Cycle | 35%/40°C | 35%/40°C |
| Efficiency | 0.8 | 0.8 |
| Power Factor | 0.75 | 0.75 |
| Protection Class | IP21S | IP21S |
| Insulation Class | F | F |
| Dimensions (mm) | 320x240x150 (12.59x9.45x5.9 inch) | 320x240x150 (12.59x9.45x5.9 inch) |
| Weight (kg) | 4.5 (9.92 LBS) | 4.5 (9.92 LBS) |


10. User Tips
- Always ensure the ground clamp is firmly attached to clean metal of the workpiece for optimal electrical contact and welding performance.
- When installing welding wire, carefully guide it through the feed roller guide track to prevent tangles and ensure smooth feeding.
- For Flux MIG welding, remember to press the torch switch to initiate wire feed and arc.
- If using a spool gun, note that it is an optional accessory and needs to be purchased separately.
- Regularly check that the welding wire diameter matches the contact tip size to avoid feeding issues and ensure consistent arc quality.
- Maintain a well-ventilated workspace to minimize exposure to welding fumes and gases.
11. Warranty and Support
HITBOX is continuously improving its products. While some parts may change, the main functions and operations remain consistent. Your understanding is appreciated.
For further assistance or inquiries, please refer to the official user manual (PDF) available at HITBOX HIM200 User Manual (PDF) or visit the manufacturer's website: WWW.HITBOXWELD.COM.