PORIYA XRD-301

Rate this product if you’ve used it
Contents

PORIYA Automotive Smoke Machine Leak Detector

Model: XRD-301

1. Introduction and Overview

The PORIYA XRD-301 Automotive Smoke Machine Leak Detector is a compact and portable diagnostic tool designed for efficient on-site vehicle repairs. It features a built-in air pump, overheat protection, and a versatile adapter kit, making it suitable for detecting leaks in various automotive systems including EVAP, fuel tank, exhaust, intake, and general car sealing tests. Its robust design allows operation in a wide range of temperatures, from -20°C to 75°C.

This manual provides essential information for the safe and effective use of your smoke leak detector. Please read it thoroughly before operation.

2. Safety Information

  • Always operate the device in a well-ventilated area.
  • Ensure the vehicle engine is off and cool before connecting the device.
  • Connect the power cord only to a 12V DC battery. Observe correct polarity (red to positive, black to negative).
  • Do not use flammable or corrosive liquids as test fluid. Only use recommended fluids such as baby oil, mineral oil, or Glycerol.
  • Avoid direct contact with the smoke. While non-toxic, prolonged exposure is not recommended.
  • Keep the device away from open flames or high heat sources.
  • Do not immerse the device in water or expose it to excessive moisture.
  • Wear appropriate personal protective equipment (PPE) such as gloves and eye protection during operation.
  • The device has overheat protection; however, do not block ventilation openings during use.

3. Package Contents

Verify that all items listed below are present in your package:

PORIYA Smoke Leak Detector and all included accessories
Figure 3.1: PORIYA Smoke Leak Detector and all included accessories.
  • PORIYA Smoke Leak Detector (XRD-301) x 1
  • Power Cord Clip x 1
  • Valve Core Wrench x 1
  • Smoke Tube x 1
  • Hook x 1
  • Cap Plugs x 8 (various sizes)
  • Universal Adapter x 1
  • Refueling Bottle (Oil not included) x 1
  • Conical Adapter x 1
  • EVAP Adapter x 1
  • Instruction Manual x 1

4. Specifications

FeatureSpecification
VoltageDC12V
Output Pressure20 - 25 PSI
Output Flow Rate6 L/min
Operating Temperature-4°F to 167°F (-20°C to 75°C)
MaterialsSteel, Aluminum, Brass, Silicone
Product Weight7.18 lbs (3.26 kg)
Product Dimensions130 × 120 × 230 mm
Diagram showing built-in air pump specifications: 20-25psi output pressure and 6L/min flow rate.
Figure 4.1: Built-in Air Pump Specifications.
Image illustrating the overheat protection feature, showing operating temperature range from -20°C to 75°C.
Figure 4.2: Overheat Protection and Temperature Range.

5. Setup

Follow these steps to prepare your PORIYA Smoke Machine for leak detection:

  1. Fill with Test Fluid: Using the provided refueling bottle, carefully add 10-20 ml of baby oil, mineral oil, or Glycerol (not included) into the designated fluid reservoir on top of the machine. Do not overfill.
  2. Prepare the System: Disconnect the part of the vehicle system you intend to test (e.g., intake manifold, EVAP line) and connect the smoke hose from the detector to the opening. Use the appropriate cap plugs or universal adapter from the kit to seal off other openings in the system to ensure a closed environment for testing.
  3. Connect Power: Connect the power cord clips to a 12V DC vehicle battery. Ensure the red clip is connected to the positive (+) terminal and the black clip to the negative (-) terminal.
  4. Position the Device: The device is designed for portability and can be hung using the integrated hook for convenient placement during maintenance.
Four-step visual guide for quick and easy leak detection: 1. Fill fluid, 2. Connect hose, 3. Connect power, 4. Turn on.
Figure 5.1: Quick and Easy Leak Detection Steps.

6. Operating Instructions

Once the setup is complete, proceed with leak detection:

  1. Turn On: Flip the power switch on the front of the smoke machine to the 'ON' position. The built-in air pump will activate, and the device will begin generating smoke.
  2. Observe for Leaks: Allow a few moments for the smoke to fill the sealed system. Visually inspect all connections, hoses, and components within the tested system for any escaping smoke. The presence of smoke indicates a leak point.
  3. Identify Leak Types: The PORIYA Smoke Machine is effective for identifying various types of leaks, including but not limited to: crankcase air leakage, front and rear oil seal leaks, intercooler air leaks, throttle body leaks, intake air duct gasket leaks, exhaust pipe leakage, leaking fuel tanks, poorly closed valves, and general air/water leaks in the system.
  4. Turn Off: Once the leak is identified or testing is complete, turn the power switch to the 'OFF' position. Disconnect the power clips from the battery and remove the smoke hose and adapters from the vehicle system.
Professional car leak detector connected to a car engine, demonstrating its use in a vehicle's engine bay.
Figure 6.1: Professional Car Leak Detector in Operation.
Grid of images showing various leak detection applications: Crankcase Air Leakage, Front and Rear Oil Seal, Intercooler Air Leak, Throttle Leak, Intake Air Duct Gasket Leak, Exhaust Pipe Leakage, Leaking Fuel Tank, Poorly Closed Valves, Air and Water Leaking.
Figure 6.2: Wide Range of Leak Detection Applications.
Image showing the detector is safe for various vehicles including Cars, Motorcycles, Light Trucks, ATV, Snowmobiles, and Boats.
Figure 6.3: Compatibility with Various Vehicle Types.

7. Maintenance

  • Fluid Refill: Regularly check the fluid level in the reservoir. Refill with recommended test fluid (baby oil, mineral oil, or Glycerol) as needed to ensure continuous smoke generation.
  • Cleaning: After each use, wipe down the exterior of the device with a clean, dry cloth. Ensure no fluid residue is left on electrical connections.
  • Storage: Store the smoke machine and its accessories in a cool, dry place, away from direct sunlight and extreme temperatures. Ensure all components are clean and dry before storage.
  • Hose and Adapter Inspection: Periodically inspect the smoke tube, power cord, and various adapters for any signs of wear, cracks, or damage. Replace any damaged components immediately to ensure safe and effective operation.

8. Troubleshooting

ProblemPossible CauseSolution
No smoke outputLow or no test fluid; Power not connected; Device not turned on; Clogged smoke tube.Check fluid level and refill; Ensure power clips are securely connected to a 12V battery; Turn on the power switch; Inspect and clear the smoke tube.
Weak smoke outputLow fluid level; Insufficient power supply; Loose connections in the vehicle system.Refill test fluid; Ensure battery has sufficient charge; Verify all adapters and caps are tightly sealed in the vehicle system.
Device not powering onIncorrect power connection; Dead vehicle battery; Faulty power switch.Check power clip polarity and connection; Test vehicle battery voltage; Contact support if switch is faulty.
Overheat protection activatedProlonged use; Blocked ventilation.Allow the device to cool down; Ensure ventilation openings are clear.

9. User Tips

No specific user tips were available from reviews or Q&A for this product at the time of manual creation.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.