RUNXIN F63C

Contents

Runxin Automatic Softener Control Valve F63C User Manual

Model: F63C | Brand: RUNXIN

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the Runxin Automatic Softener Control Valve F63C. This valve is designed for use in water treatment systems, including residential filter systems and RO pretreatment systems, offering efficient and reliable control over filtration and regeneration processes.

Front view of the Runxin F63C Automatic Softener Control Valve
Figure 1: Front view of the Runxin F63C Automatic Softener Control Valve.

2. Safety Information

  • Read all instructions carefully before installation and operation.
  • Ensure the power supply matches the valve's requirements.
  • Turn off the main water supply and depressurize the system before performing any maintenance or installation.
  • Avoid exposing the control valve to direct sunlight or extreme temperatures.
  • Only qualified personnel should perform electrical connections and complex plumbing.

3. Package Contents

Verify that all components are present and undamaged upon unpacking. The standard package includes:

  • Automatic Softener Control Valve (F63C)
  • Power Adapter
  • Interlock Line
  • Base Sealing Ring
  • Flat Gasket
  • Drainage Hose Connection
  • Water Injection Current Limiting Gasket
  • Screened Pipe
  • Salt Absorption Hose Connection
  • Accessories Box
  • User Manual (this document)
Image showing various components included in the package: power adapter, interlock line, base sealing ring, flat gasket, drainage hose connection, water injection current limiting gasket, screened pipe, salt absorption hose connection, accessories box, and user manual.
Figure 2: Typical package contents for the control valve.

4. Product Overview and Features

The Runxin F63C control valve features an innovative design with high-degree pottery sealing and multi-flow channels, ensuring reliable performance for water treatment applications. It is certified by NSF, CE, and RoHS.

Key Features:

  • Power Cut Indication: Indicates long-time power cuts.
  • Data Retention: Data is saved for three days after power loss.
  • No Hard Water Bypass: Ensures no hard water bypass during the rising cycle.
  • Remote Handling: Equipped with remote handling connector b-01(02).
  • Flexible Regeneration Settings: Backwash and fast rinse frequencies can be set (F-00), allowing for service one time and multiple backwash and fast rinse cycles.
  • Remote Signal Input: Includes a remote signal input connector.
  • Interlock Function: For contemporary systems and individual rising.
  • Regeneration Initiation: Can start rising by days or hours (time type or meter type options).
  • Dual Valve Cores (for F77IF95/F111 models): One for controlling water in, the other for water out.
Close-up view of the control panel and valve body, highlighting the digital display and control buttons.
Figure 3: Control panel and valve details.
Diagram showing the dimensions of the control valve: 195.5mm width (side view) and 182.5mm width x 143mm height (front view).
Figure 4: Product dimensions.

5. Specifications

AttributeValue
Brand NameRUNXIN
Product NameControl valve
ModelF63C (based on product title, other models available)
Installation MethodSelf-contained
ApplicationFiltration, Pretreatment
Capacity250L~10000L (for various models)
ProductivityUp to 50 M3/H (depending on model)
Weight (KG)3 kg (for F63C, may vary by model)
CertificationNSF, CE, RoHS
Filter MediaSand+carbon+resin (all Included, for specific applications)
Warranty1 Year
Warranty of Core Components1 Year (Core Components: PLC)
OriginMainland China

Model-Specific Flow and Tank Data:

Product ModelInletOutletDrainBaseRiser PipeWater CapacityTank Diameter Range For Filters
53502 (F71B1)3/4" M3/4" M3/4" M2.5"-8NPSM1.05" OD2 M3/H6"-10"
56603 (F67M)3/4" M3/4" M3/4" M2.5"-8NPSM1.05" OD3 M3/H6"-10"
53502B (F71G1)3/4" M3/4" M3/4" M2.5"-8NPSM1.05" OD2 M3/H6"-10"
53504S (F67B1)1" F1" F1" F2.5"-8NPSM1.05" OD4 M3/H6"-14"
53506S (F67B-A)1" F1" F1" F2.5"-8NPSM1"D-GB6 M3/H6"-14"
53504 (F67C1)1" F1" F1" F2.5"-8NPSM1.05" OD4 M3/H6"-14"
53504B (F67G1)1" F1" F1" F2.5"-8NPSM1.05" OD4 M3/H6"-14"
53504C (F67I1)1" F1" F1" F2.5"-8NPSM1.05" OD4 M3/H6"-14"
53510 (N75A1)2" M2" M2" M4"-8NPSM1.5"D-GB 1.9" OD10 M3/H16"-24"
53510B (N75B1)2" M2" M2" M4"-8NPSM1.5"D-GB 1.9" OD10 M3/H16"-24"
53515 (F99B1)2" M2" M2" M4"-8NPSM1.5"D-GB 1.9" OD15 M3/H14"-30"
53518 (N77B1)2" M2" M2" M4"-8NPSM1.5"D-GB 1.9" OD18 M3/H24"-30"
53520 (F95B1)2" M2" M2" M4"-8NPSMSIDE-MOUNTEDC20 M3/H28"-40"
53520T (F111B1)2" M2" M2" M4"-8NPSM2"D-GB20 M3/H28"-40" Top Mounted
53540 (F112B1)DN65DN65DN65Side-Mounted, DN80 Top and Bottom Strainer ConnectorN/A40 M3/H36"-40"
53550 (F96B1)DN80DN80DN80Side-Mounted, DN100 Top and Bottom Strainer ConnectorN/A50 M3/H36"-48"
NSF International certification for Wenzhou Runxin Manufacturing Machine Co., Ltd., complying with NSF/ANSI 61.
Figure 5: NSF/ANSI 61 Certification.
NSF International certification for Wenzhou Runxin Manufacturing Machine Co., Ltd., complying with NSF/ANSI 44.
Figure 6: NSF/ANSI 44 Certification.

6. Installation and Setup

The Runxin F63C control valve is designed for self-contained installation. Proper installation is crucial for optimal performance and longevity of your water treatment system. It is recommended that installation be performed by a qualified professional.

General Installation Steps:

  1. Prepare the System: Turn off the main water supply and relieve pressure from the system.
  2. Mount the Valve: Securely mount the control valve onto the water treatment tank. Ensure the base sealing ring is correctly positioned.
  3. Connect Water Lines: Connect the inlet, outlet, and drain lines to the corresponding ports on the valve. Use appropriate fittings and ensure all connections are watertight. Refer to Figure 7 for connection points.
  4. Install Riser Pipe: Insert the riser pipe into the tank and connect it to the valve as per your system's design.
  5. Connect Drainage Hose: Attach the drainage hose to the drainage hose connection on the valve.
  6. Electrical Connection: Connect the power adapter to the valve and plug it into a suitable electrical outlet. If applicable, connect the interlock line and remote signal input connector.
  7. Check for Leaks: Slowly turn on the main water supply and check all connections for leaks.
  8. Initial Programming: Proceed to the Operating section for initial programming and settings.
Back view of the control valve showing the inlet, outlet, and drain connections.
Figure 7: Rear view with connection points.

7. Operating Instructions

The F63C control valve features a user-friendly interface for programming and monitoring. The digital display shows current status and settings.

Control Panel Overview:

Refer to Figure 3 for a visual representation of the control panel. The buttons typically include:

  • SET/MENU: Enters programming mode or confirms settings.
  • UP/DOWN Arrows: Navigates through menu options or adjusts values.
  • REGENERATE: Initiates a manual regeneration cycle.

Initial Programming:

  1. Set Time of Day: Enter programming mode and set the current time.
  2. Select Regeneration Type: Choose between "Time Type" (regeneration based on a set schedule) or "Meter Type" (regeneration based on water volume processed).
  3. Configure Regeneration Frequencies (F-00):
    • Set the frequency for backwash and fast rinse cycles.
    • The system can be configured for service one time, followed by multiple backwash and fast rinse cycles.
  4. Set Regeneration Start Time/Volume:
    • For Time Type: Set the specific days or hours for regeneration.
    • For Meter Type: Set the water volume threshold that triggers regeneration.
  5. Save Settings: Exit programming mode to save all configurations.

Power Outage Data Retention:

The valve is designed to retain programmed data for up to three days in the event of a power cut. After a power outage, the display will indicate a long-time power cut. Verify and reset the current time if necessary.

8. Maintenance

Regular maintenance ensures the longevity and efficient operation of your Runxin F63C control valve and water treatment system.

  • Regular Cleaning: Periodically clean the exterior of the valve with a soft, damp cloth. Avoid abrasive cleaners.
  • Check for Leaks: Regularly inspect all plumbing connections for any signs of leaks. Address any leaks promptly.
  • Inspect Seals and Gaskets: Over time, seals and gaskets may wear out. Inspect them during system maintenance and replace if necessary to prevent leaks and ensure proper valve function.
  • Monitor Regeneration Cycles: Ensure the regeneration cycles are occurring as programmed and that the system is effectively treating water.
  • Power Adapter Check: Ensure the power adapter is securely connected and free from damage.

9. Troubleshooting

This section provides solutions to common issues you might encounter.

ProblemPossible CauseSolution
Valve not regeneratingIncorrect programming; Power outage; Sensor issue (meter type)Check programming settings (time/meter type, frequency). Verify power supply. Inspect meter sensor if applicable.
Water leakage from valveLoose connections; Damaged O-rings/sealsTighten all connections. Inspect and replace any worn or damaged O-rings or gaskets.
Display not workingNo power; Faulty display/electronicsCheck power adapter connection and power outlet. If power is present, contact support.
System not softening water effectivelyInsufficient regeneration; Incorrect salt dosage (for softeners); Media degradationEnsure regeneration cycles are frequent enough. Check salt levels and brine draw. Consider media replacement if old.

10. User Tips

  • For optimal performance, ensure your water treatment system's media (sand, carbon, resin) is appropriate for your water quality and replaced as recommended by the media manufacturer.
  • Regularly check the salt level in your brine tank if using the valve for a water softener application.
  • Familiarize yourself with the control panel buttons and their functions to quickly adjust settings or initiate manual cycles when needed.

11. Warranty and Support

The Runxin Automatic Softener Control Valve F63C comes with a 1-Year Warranty. This warranty covers manufacturing defects for the valve itself and its core components (e.g., PLC) for a period of one year from the date of purchase.

For technical support, warranty claims, or service inquiries, please contact your local distributor or the manufacturer directly. Ensure you have your purchase details and product model number available.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.