1. Introduction and Product Overview
This manual provides detailed instructions for the installation, operation, and maintenance of the JIKONG Lithium Battery Active Balance Protection Board (BMS). Please read this manual thoroughly before use to ensure proper and safe operation.
The JIKONG intelligent lithium battery protection board is a management system designed for large-capacity series lithium battery packs. It features voltage acquisition, high-current active balancing, overcharge/over-discharge/over-current/over-temperature protection, coulomb meter, Bluetooth communication, and optional GPS remote functions. It is suitable for lithium iron phosphate, ternary lithium, and lithium titanate battery types.
The protection board relies on energy transfer active balancing technology with independent intellectual property rights, which can achieve a maximum continuous 2A balance current. This high-current active equalization technology ensures battery consistency, improves battery range, and delays battery aging.
A mobile APP supporting Android and iOS operating systems is available. The APP connects to the protection board via Bluetooth, allowing users to check battery status, modify working parameters, and control charge/discharge switches. The compact and fully functional protection board is widely used in battery packs for small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage, base station backup power supplies, solar power stations, and other products.


2. Safety Protection Measures and Precautions
Before using the protection board, carefully read this instruction manual. Connect the cables from the negative terminal to the positive terminal according to the wiring diagram for the corresponding number of strings. After connecting the balance wires, use a multimeter to confirm correct wiring before inserting the protection board.
The default password for the protection board is "1234", and the default authorization password is "123456". After connecting the mobile phone APP to the protection board, change the connection password promptly to prevent unauthorized access.
Warning:
- It is strictly forbidden to modify the power lines of the protection board without permission. Unauthorized modifications can lead to uneven overcurrent and damage to the protection board.
3. Specifications
3.1. Functional Characteristics
- LED Bluetooth status indicator
- APP Bluetooth remote operation
- Battery capacity calculation
- High precision voltage acquisition (±3mV)
- High precision current acquisition
- Support information screen display
- Accurate time logging
- Support RS485 (Optional)
- Support CAN (Optional)
- Support ACC detection function (Optional)
- Support parallel function (Optional)
- Support alarm function (Optional)
- Support heating function (Optional)
- Support GPS communication
- Charge overcurrent protection
- Charge overvoltage protection
- Charge over temperature protection
- Low temperature protection during charge
- Discharge overcurrent protection
- Discharge undervoltage protection
- Discharge over temperature protection
- Short circuit protection
3.2. Product Specifications Table

3.3. Basic Parameters
| Item | Parameter | Unit |
|---|---|---|
| Supply voltage | 7.5-36 | V |
| Operating power consumption | <1400 | mW |
| Operating temperature | -30-70 | °C |
| Maximum number of collection strings | 8 | String |
| Maximum balancing current | 2 | A |
| Maximum charging current | 300 | A |
| Maximum discharge current | 300 | A |
| Maximum instantaneous current | 600 | A |
| Maximum internal loop resistance | 0.25 | mΩ |
| Protective plate size | 182.75*127.26*15.6 | mm |
| Finished weight | 541 | g |
3.4. Default Parameters
The following table outlines the default parameters for various battery types. These can be adjusted via the mobile APP as needed.
| Parameter | Li-ion (Default) | LiFePO4 (Default) | LTO (Default) | Unit |
|---|---|---|---|---|
| Balancing initial voltage | 3 | 3 | 2 | V |
| Maximum balancing current | 2 | 2 | 2 | A |
| Unit overcharge voltage | 4.2 | 3.6 | 2.7 | V |
| Overcharge protection recovery | 4.18 | 3.55 | 2.65 | V |
| Monomer undervoltage protection | 2.82 | 2.6 | 1.8 | V |
| Undervoltage protection recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic shutdown voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger balancing differential pressure | 0.01 | 0.01 | 0.01 | V |
| Charging overcurrent protection delay | 30 | 30 | 30 | S |
| Charging overcurrent protection release time | 60 | 60 | 60 | S |
| Discharge overcurrent protection delay | 300 | 300 | 300 | S |
| Discharge overcurrent protection release time | 60 | 60 | 60 | S |
| Short-circuit protection delay | 5 | 5 | 5 | uS |
| Short circuit protection release time | 30 | 30 | 30 | S |
| Charging overtemperature protection | 70 | 70 | 70 | °C |
| Charging overtemperature restore temperature | 60 | 60 | 60 | °C |
| Discharge overtemperature protection | 70 | 70 | 70 | °C |
| Discharge overtemperature recovery | 60 | 60 | 60 | °C |
| Charging low temperature protection | -20 | -20 | -20 | °C |
| Charging low temperature to restore temperature | -10 | -10 | -10 | °C |
| MOS Overtemperature protection | 100 | 100 | 100 | °C |
| MOS Overtemperature protection recovery | 80 | 80 | 80 | °C |
| Device address | 0 | 0 | 0 | / |
4. Installation and Wiring
4.1. Packing List
Upon unpacking, please verify that all components are present:
- BMS x 1
- Sampling line x 1 (length 70cm)
- NTC x 1 (length 40cm)
- Switch x 1 (length 50cm)

4.2. Product Dimensions

4.3. Wiring Instructions
The JK-B2A8S-30P series protection board is suitable for 3-8 series lithium battery packs. The specific wiring method varies depending on the number of cells in the battery pack.
- Connect all cables.
- Insert the cables into the BMS.
- Connect the B-line and the P-line to the battery.


The protection board's interface definitions are crucial for correct wiring. Refer to the table below for detailed pin assignments:
Interface Definitions
| Connector | Interface Name | Pin No. | Pin Name | Definition |
|---|---|---|---|---|
| P1 (XH-10AW-2.54) | Balance with Acquisition interface | 1 | B- | Total negative battery |
| 2 | B1 | The first battery positive | ||
| 3 | B2 | The second battery positive | ||
| 4 | B3 | The third battery positive | ||
| 5 | B4 | The fourth battery positive | ||
| 6 | B5 | The fifth battery positive | ||
| 7 | B6 | The sixth battery positive | ||
| 8 | B7 | The seventh battery positive | ||
| 9 | B8 | The eighth battery positive | ||
| 10 | B+ | Protection board power supply, connected to the battery | ||
| P2 (A1254WF-2A, Optional) | Alarm interface | 1 | GND | Alarm power negative |
| 2 | VCC | Alarm power supply positive | ||
| P3 (A1254WF-4A, Optional) | Communication interface | 1 | CAN L | CAN signal negative terminal |
| 2 | CAN H | CAN signal positive terminal | ||
| 3 | RS485 A | RS485 signal positive terminal | ||
| 4 | RS485 B | Negative terminal of RS485 signal | ||
| P4 (1.25T-4PWT) | GPS interface | 1 | GND | Power/signal ground |
| 2 | RX | UART RX, 3.3V | ||
| 3 | TX | UART TX, 3.3V | ||
| 4 | VGPS | Power output, the voltage is close to B+ | ||
| P5 (HY2.0-4P, 4 external optional configuration) | Temperature interface | 1 | T5A | Fifth temperature sensor pin A |
| 2 | T5B | Fifth temperature sensor pin B | ||
| 3 | T4A | Fourth temperature sensor pin A | ||
| 4 | T4B | Fourth temperature sensor pin B | ||
| 1 | T2A | Second temperature sensor pin A | ||
| 2 | T2B | Second temperature sensor pin B | ||
| 3 | T1A | First temperature sensor pin A | ||
| 4 | T1B | First temperature sensor pin B | ||
| P7 (A1254WF-5A, Optional) | ACC interface | 1 | ACC+ | ACC Positive |
| 2 | ACC- | ACC Negative | ||
| 3 | NC | Empty | ||
| 4 | C_Detect+ | The charger output 12V positive | ||
| 5 | C_Detect- | The charger output 12V negative | ||
| P8 (A1254WF-6A) | Display interface | 1 | VCC | Display power output |
| 2 | A | The display RS485 signal is positive | ||
| 3 | B | The display RS485 signal negative | ||
| 4 | GND | Negative terminal | ||
| 5 | K+ | Activation signal positive | ||
| P9 (A1254WF-3A, Optional) | Parallel interface | 1 | P-status | Parallel module status signal |
| 2 | P-EN | Parallel module enable signal, output low level Turn on parallel module | ||
| 3 | GND | Signal ground | ||
| Heating wire (16AWG) | Heating wire | 1 | HT- | Heater element negative electrode |
| D1 | Bluetooth connection indicator: Steady on when connected, blinking when disconnected. | |||
| P- | Connect to external load or negative terminal of charger, equipped with M6 screws. | |||
| B- | Connect to the negative battery terminal, equipped with M6 screws. | |||
5. Operation Instructions
5.1. Device Activation
Before powering on the protection board, ensure the balance cable is correctly connected and that P- and B- are securely connected to the battery cells. Verify that the protection board is firmly fixed to the battery pack. Incorrect connections can lead to abnormal operation or even damage.
The protection board does not have a physical power-on control switch. It is designed for charging activation mode (charger voltage 2V higher than battery voltage). After battery assembly, connect the charger to activate the protection board.
Alternatively, the protection board supports activation via a key switch or display. If you have an optional display screen and button, simply connect the cable to the display interface and press the button to activate.
5.2. Mobile APP and Display Operation
The JIKONG BMS has a mobile APP for Android and iOS, allowing users to monitor and control the BMS remotely via Bluetooth. The APP supports multiple languages and automatically switches with the mobile phone system.

The display interface provides clear, at-a-glance information about the battery's status.


To download the mobile APP, scan the QR code below. Android Version 7 or higher is required.

5.3. Parameter Setting
Users can set various parameters via the APP, including battery type, number of cells, battery capacity, trigger equalization differential pressure, voltage calibration, and current calibration. Refer to the "Instructions for Setting Protection Board Parameters" within the APP for detailed guidance.
5.4. Active Balancing
The BMS employs active equalization technology to transfer energy from higher-voltage cells to lower-voltage cells, ensuring voltage balance with minimal energy loss. This process operates continuously when a voltage difference above the set threshold is detected, whether charging, discharging, or idle.

The default active balancing current is 2A. Users can adjust this current via the APP based on their battery capacity, with a recommendation not to exceed 0.2C of the battery capacity. If active balancing is not required, it can be disabled in the BMS control page of the APP.
5.5. Communication Functions (Optional)
The protection board supports optional CAN and RS485 communication functions. Users can select these functions based on their requirements. When using communication, the address and protocol can be set via the APP. Refer to the Jikong Protection Board communication protocol document for specific details.

6. Protection Features
The JIKONG BMS includes a comprehensive suite of protection features to ensure the safety and longevity of your battery pack.
6.1. Overcharge Protection and Recovery
The BMS provides standard overcharge protection. Users can set the single overcharge protection voltage and recovery voltage via the APP. If any cell exceeds the set overcharge voltage during charging, the BMS will stop charging. Charging resumes when all cell voltages drop below the recovery voltage.
6.2. Undervoltage Protection and Recovery
Standard undervoltage protection is included. Users can set the undervoltage protection voltage, recovery voltage, and automatic shutdown voltage via the APP. If any cell drops below the set undervoltage protection voltage during discharge, the BMS will stop discharging. Discharge resumes when all cell voltages rise above the recovery voltage. If any cell drops below the automatic shutdown voltage, the BMS will shut down to protect the battery.
6.3. Overcurrent Protection and Recovery (Charge/Discharge)
The BMS features standard charge and discharge overcurrent protection. Users can set continuous charge/discharge currents, overcurrent delay times, and recovery times via the APP. If the current exceeds the set value for the specified delay, protection is triggered, and the BMS stops the respective operation. Operation resumes after the set recovery time.
Note: The maximum continuous discharge current should not exceed the design value of 300A.
6.4. Overtemperature and Low Temperature Protection and Recovery
Standard overtemperature and low temperature protection for both charging and discharging are provided. Users can set the protection and recovery temperatures via the APP. If the battery temperature exceeds the overtemperature threshold, charging/discharging stops. Operation resumes when the temperature returns to the recovery range. For low temperature protection during charging, if the temperature drops below the set value, charging stops and resumes when the temperature rises above the recovery value. In extremely cold environments, using the optional heating function is recommended.
6.5. Short Circuit Protection and Recovery
The BMS includes standard short circuit protection. Users can set the short circuit protection delay and recovery time via the APP. The current threshold for short circuit protection is automatically managed. If a short circuit is detected, the BMS will stop operation and resume after the recovery time. If a short circuit occurs during initial charger connection or load connection, increasing the delay time in the APP may resolve issues caused by peak currents or large load capacitances.
6.6. Emergency Switch
The emergency switch function allows the BMS to continue charging and discharging for 30 minutes in case of issues like over-temperature, over-discharge, over-charge, or cell drop. This provides a temporary operational window. Even if a single cell reaches automatic shutdown voltage during this period, the BMS will continue to operate for the full 30 minutes to prevent critical situations.
6.7. Intelligent Sleep
The intelligent sleep function is standard. Users can enable or disable it via the APP. When enabled, the BMS will enter sleep mode if the charging and discharging current is less than 1A for 26 consecutive hours, reducing self-consumption. The BMS can be reactivated by pressing a button (if equipped) or by connecting a charger.
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your JIKONG BMS.
- Periodic Inspection: Regularly check all wiring connections for tightness and corrosion. Ensure the BMS is securely mounted.
- Software Updates: Keep the mobile APP updated to the latest version to benefit from new features and bug fixes.
- Parameter Review: Periodically review the BMS parameters in the APP to ensure they are still appropriate for your battery configuration and usage patterns.
- Cleaning: Keep the BMS unit clean and free from dust and debris to ensure proper heat dissipation. Use a soft, dry cloth for cleaning.
8. Troubleshooting
This section provides guidance on common issues and their potential solutions.
- BMS Not Activating: Ensure all wiring is correct and secure. The BMS activates upon connecting a charger (charger voltage 2V higher than battery voltage) or by pressing the activation button on an optional display.
- Balancing Not Occurring: Check the active equalization settings in the APP. Ensure the balance trigger differential pressure is set correctly and that the function is enabled. Verify that the battery cells are within the voltage range for balancing.
- Frequent Protection Triggers (Overcurrent, Overvoltage, etc.): Review the default and custom parameter settings in the APP. Adjust current limits, voltage thresholds, and delay times as appropriate for your battery and load. For short circuit protection, consider increasing the delay time if false triggers occur during startup.
- Bluetooth Connection Issues: Ensure the BMS is powered on and within range. Check the Bluetooth indicator LED (steady on when connected, blinking when disconnected). Restart the APP or your mobile device if necessary.
- Heating Function Not Working: Verify that the heating function is enabled in the APP and that the temperature is below the set low-temperature protection threshold. Check the external temperature control switch (if installed) and the heating circuit.
For persistent issues, consult the detailed "Instructions for Setting Protection Board Parameters" within the APP or contact JIKONG customer support.
9. User Tips
- For optimal battery life, try to keep cell voltages balanced. The active balancing feature of this BMS helps significantly with this.
- Regularly monitor battery health and performance through the mobile APP. This can help identify potential issues before they become critical.
- When setting protection parameters, always consider the specifications of your specific battery cells to avoid premature cut-offs or insufficient protection.
- In cold climates, utilizing the optional heating function can greatly improve battery performance and charging efficiency.
10. Support and Contact
For further assistance, technical support, or inquiries, please contact JIKONG customer service. Refer to the official JIKONG website for the most up-to-date contact information.
Manufacturer: Chengdu Jikong Technology Co.LTD
For detailed documentation, you may also refer to the User Manual (PDF).