ZOYI ZT-MD2

Contents

ZOYI ZT-MD2 Intelligent Tweezers LCR Digital Bridge Tester User Manual

Model: ZT-MD2

1. Introduction

1.1 Overview

The ZOYI ZT-MD2 is a compact digital LCR tweezers bridge designed for precise measurement of electronic components. It features a vibrant TFT color display for clear and intuitive operation. Powered by a rechargeable lithium polymer battery, it offers extended usage and standby times.

This intelligent device automatically identifies resistors, capacitors, and inductors, providing accurate measurements with a maximum frequency of 100kHz. It also supports sweep frequency measurement. Beyond traditional LCR functions, the ZT-MD2 includes diode testing, continuity testing, ±32VDC voltage measurement, and a signal generator output function.

Its small, elegant, and portable design, combined with elastic tweezer arms and removable gold-plated measuring tips, ensures flexible and reliable operation. It is an ideal tool for various applications, including factory SMD work, repair, educational purposes, and research & development.

1.2 Safety Precautions

To prevent potential electric shock, fire, and personal injury, please adhere to the following safety guidelines:

  • Do not measure voltages exceeding the rated range to avoid damage to the meter and personal injury.
  • Do not perform LCR measurements on live circuits. Always ensure capacitors are fully discharged before measurement.
  • Avoid using or storing this product for prolonged periods in high-temperature, dusty environments, or under direct sunlight.
  • Do not use this product in the presence of explosive gases, vapors, or in damp environments.

2. Product Features

The ZOYI ZT-MD2 LCR Tester offers a range of advanced features for comprehensive component analysis:

  • Smart Recognition & Auto Measurement: Automatically identifies electronic components and displays primary and secondary parameters.
  • Multiple Test Frequencies: Supports 100Hz, 120Hz, 1KHz, 10KHz, and 100KHz for versatile testing.
  • 7 Waveform Outputs: Includes TRI, FULL, TRAP, PWM, HALF, SIN, and NIOS waveforms for signal generation.
  • Data Hold & Export: Supports data hold and automatic recording into Excel files for computer viewing.
  • DC Voltage Measurement: Capable of measuring DC voltage below 30V.
  • Comparison Function: Preset a reference value for components to automatically compare and output Pass/Fail results.
  • Auto Screen Rotation: Screen orientation can be freely adjusted for convenience.
  • Gold-Plated Clips: Ensures reliable contact and accurate measurements.
  • CNC Metal Housing: Durable and robust construction.
ZOYI ZT-MD2 Tweezer LCR Meter highlighting key features
Key features of the ZOYI ZT-MD2 Tweezer LCR Meter.
ZOYI ZT-MD2 displaying 7 waveform outputs
The ZT-MD2's 7 waveform outputs for signal generation.
ZOYI ZT-MD2 performing various measurements: resistance, inductance, capacitance, and voltage
Measurement capabilities of the ZT-MD2, including resistance, inductance, capacitance, and voltage.

2.1 Video Demonstration

A short video demonstrating the unboxing and various measurement functions of the ZOYI ZT-MD2 LCR Tester.

3. Specifications

3.1 Technical Specifications

FunctionRangeAccuracy
100Hz120Hz1KHz10KHz100KHz
Resistance1MΩ~10MΩ5%±55%±45%±5------
1KΩ~1MΩ1%±30.7%±30.5%±21%±25%±3
1Ω~1KΩ1%±30.7%±30.5%±21%±25%±3
10mΩ~1Ω---------------
Capacitance1mF~22mF5%±35%±35%±3------
1uF~1mF2%±32%±31%±32%±35%±3
1nF~1uF2%±32%±30.5%±21%±20.5%±3
1pF~10nF------1%±31%±3---
Inductance1H~10H5%±25%±25%±2------
1mH~1H5%±35%±30.5%±2------
10uH~1mH------0.5%±20.7%±35%±3
1uH~10uH------2%±32%±35%±3
ParametersRs/Rp/Cs/Cp/Ls/Lp/P/D/Q/X/Z
Gear PositionVoltage, Sweep, Signal Output, Auto, Resistance, Capacitance, Inductance, Diode
Frequency100Hz, 120Hz, 1KHz, 10KHz, 100KHz
Voltage0.1V, 0.3V, 0.6V
Charging✓
Diode✓
DisplayOLED
Upgrade✓

3.2 General Technical Specifications

  • Display: 1.47-inch TFT
  • Sampling Rate: 1 time/sec
  • Data Hold: Yes
  • Languages: Chinese, English
  • Screen Orientation: Auto, Left, Right
  • Volume Settings: 0% - 100%
  • Backlight Brightness: 10% - 100%
  • Auto Power Off: Off, 5 min, 120 min
  • Low Battery Warning: Yes
  • Dimensions: 145*29*14mm
  • Weight: 50g
  • Battery: Lithium polymer rechargeable 3.7 V, 300 mAh
  • Housing Material: CNC aluminum alloy
Technical Specifications table for ZOYI ZT-MD2
Detailed technical specifications of the ZOYI ZT-MD2 LCR Tester.

4. Setup and Basic Operation

4.1 Unboxing and Components

Upon opening the package, you should find the ZOYI ZT-MD2 LCR Tester, a USB Type-C charging cable, and a protective case. Ensure all components are present and undamaged.

ZOYI ZT-MD2 product packaging and included accessories
The ZOYI ZT-MD2 LCR Tester and its accessories, including the charging cable and protective case.

4.2 Power On/Off

  • Power On: Press and hold the Power key (KEY1) until the screen illuminates.
  • Power Off: Long press the Power key (KEY1) to turn off the device.

4.3 Screen Orientation

The ZT-MD2 supports automatic screen rotation, allowing the display to adjust freely based on the device's orientation for optimal viewing.

ZOYI ZT-MD2 demonstrating automatic screen orientation adjustment
The ZT-MD2's screen automatically adjusts its orientation for user convenience.

4.4 Key Functions Overview

Key NameKEY4 (Frequency)KEY3 (Level)KEY2 (Function)KEY1 (Power)
Measurement InterfaceShort Press: Set Frequency
Long Press: Speed
Short Press: Level
Long Press: Tare
Short Press: Function
Long Press: Power Off
Short Press: Hold
Long Press: Power Off
Setting InterfaceShort Press: Exit
Long Press: Cancel
Short Press: Up
Long Press: ---
Short Press: Down
Long Press: ---
Short Press: Confirm
Long Press: Power Off

5. Measurement Modes

5.1 LCR Measurement

  1. Press KEY2 to select the desired LCR measurement mode (Resistance, Capacitance, or Inductance).
  2. Press KEY3 to choose the measurement level (typically 0.6 V).
  3. Press KEY4 to select the measurement frequency (typically 1 kHz).
  4. Place the tweezer tips across the component under test. Once the reading stabilizes, read the value displayed on the screen.

Note:

  • When measuring small resistances, ensure good surface contact. Oxidation on the surface may affect accuracy.
  • Discharge capacitors before measurement to prevent residual charge from damaging the instrument.
  • Use high frequency for small capacitors and low frequency for large capacitors; use high frequency for small inductors and low frequency for large inductors; for resistors, use 1 kHz.
  • Since the tweezer uses a two-wire measurement method, contact resistance cannot be ignored. It is recommended to use the REL (tare) function.
  • For impedances greater than 1 Ω or capacitances greater than 1 nF, calibration with REL is not necessary.
ZOYI ZT-MD2 performing smart recognition auto measurement
Smart recognition and auto measurement in action.

5.2 Diode and Continuity Measurement

Switch manually to the diode mode using KEY2. Place the tweezer tips across the diode terminals. The screen will display the diode’s polarity and forward voltage.

Note:

  • The diode symbol shown on the screen corresponds to the physical orientation of the diode under test, allowing polarity identification.
  • The forward voltage reading of the diode is for reference only. The measurement range is Vf 0.1 V – 0.9 V. If the reading exceeds this range, the screen will display “OL.” For higher precision requirements, use a professional diode tester.

5.3 DC Voltage Measurement

  1. Press KEY2 to switch to the voltage measurement function. The screen will display a measurement range of –32 V to +32 V.
  2. Place the tweezer tips across the voltage to be measured.
  3. Read the voltage value shown on the screen. The device will automatically determine the polarity based on the sign.

Note:

  • Do not exceed the rated input voltage range at the tweezer tips; otherwise, the device may be damaged.
  • The device cannot measure AC voltage. Do not apply AC input.
  • Do not apply voltage while in other measurement modes.
ZOYI ZT-MD2 measuring DC voltage
Measuring DC voltage with the ZT-MD2.

5.4 Sweep Frequency Mode Measurement

In sweep frequency mode, the parameters of a component can be observed at different frequencies, which is useful for analyzing the frequency characteristics of the component.

  1. Press KEY2 to switch to the sweep frequency function.
  2. Press KEY4 to select capacitance, resistance, or inductance.
  3. Place the tweezer tips across the component under test and read the parameter values displayed on the screen.
ZOYI ZT-MD2 performing sweep frequency measurement
Automatically and continuously measuring component parameters at different frequencies.

5.5 Signal Generator Function

The ZT-MD2 is equipped with a signal generator output function. Available output signals include sine wave, square wave, triangle wave, staircase wave, half wave, full wave, and noise wave. The maximum frequency for sine wave is 100 kHz, while the maximum frequency for other signals is 10 kHz.

  1. Press KEY2 to switch to the signal function, then press KEY1 to confirm.
  2. Press KEY1 to select the waveform, then use KEY2 or KEY3 to choose the waveform type.
  3. Use the same method to adjust the signal frequency, amplitude, and duty cycle.
  4. Once settings are completed, the configured waveform will be output synchronously from both tweezer tips.

5.6 Sorting Mode

When measuring resistance, capacitance, or inductance, press and hold KEY2 and KEY3 simultaneously to enter the sorting measurement mode. In sorting mode, press and hold KEY4 to set the nominal value and tolerance. Based on the preset nominal value and tolerance, the instrument will automatically determine PASS or FAIL during measurement and record the count.

ZOYI ZT-MD2 comparison function for component sorting
The comparison function helps in sorting components based on preset values.

6. Advanced Settings and Maintenance

6.1 System Settings

Press and hold the KEY4 (Frequency key) to enter or exit the system settings interface. Within the settings, you can adjust:

  • Language: Chinese, English
  • Screen Orientation: Auto, Right-handed, Left-handed
  • Brightness: 10%~100%
  • Volume: 0%~100%
  • Auto Power Off: Off, 5 min, 30 min, 60 min, 120 min
  • Measurement Speed: Slow, Medium, Fast
  • Measurement Mode: Auto, Series, Parallel
  • Secondary Parameter Selection: Auto, Z, X, P
  • Function Selection: Resistance, Capacitance, Inductance, Diode, Voltage, Frequency Sweep, Signal
  • Calibration Settings: Open circuit, Short circuit, Resistance, Voltage
  • Restore Factory Settings: Restore all settings to factory defaults

6.2 Calibration Instructions

Calibration can be performed for specific ranges (0 Ω, 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ, 1 MΩ, 10 MΩ, OPEN, and Voltage) or all ranges sequentially.

  1. Enter the settings menu, select the “Calibration Settings” option, and use KEY2 or KEY3 to choose the calibration range.
  2. Place the tweezer tips firmly across the standard source, then press KEY1 to confirm and start calibration.
  3. The calibration process takes approximately 20 seconds. Upon completion, the buzzer will sound a single “beep” and the screen will display “Success.” If the calibration value is incorrect, the buzzer will sound two short “beeps” and the screen will display “Failure.”

Note:

  • Use SMD carbon film resistors as calibration standards. Do not use wire-wound resistors.
  • During short-circuit calibration, ensure the tweezer tips are reliably shorted and kept as far as possible from interference sources.
  • For OPEN calibration, do not connect any resistor—keep the tweezer tips open.
  • Do not connect the charging cable or Bluetooth adapter during calibration.
  • To restore factory calibration data, simply perform a factory reset.

6.3 Firmware Upgrade

To upgrade the firmware:

  1. With the device powered off, press and hold the KEY4 (Frequency key), then simultaneously press and hold the KEY1 (Power key) until “Bootloader” appears on the screen.
  2. Connect the device to a computer using a Type-C data cable. A USB drive will appear on the computer.
  3. Copy the prepared upgrade file into the USB drive. The upgrade will start automatically.
  4. Once completed, the screen will return to the measurement interface, indicating a successful upgrade.

6.4 PC Connectivity (Extended Function)

The ZT-MD2 includes a PC connectivity feature. When the USB cable is connected to a computer and the upper computer software is opened, users can customize function settings and display colors according to their personal preferences and usage habits.

ZOYI ZT-MD2 connected to a laptop for data export
The ZT-MD2 supports data hold and automatic recording into Excel files for computer viewing.

6.5 Maintenance

  • Do not attempt to open or repair this product, or modify the circuitry.
  • Clean the device with a damp cloth and mild detergent. Do not use corrosive agents or solvents.
  • Dust or moisture on the test ports may affect measurement accuracy.
  • If the tweezer tips become worn, oxidized, or damaged, they can be replaced by removing the 4 screws (type: 3.5PM2*3) and installing new tips. Ensure screws are securely tightened.

7. Troubleshooting & User Tips

7.1 Troubleshooting

  • Inaccurate Readings: Check for good contact between the tweezer tips and the component. Ensure the component is clean and free of oxidation. Verify correct measurement mode and frequency settings. Consider performing a calibration if issues persist.
  • “OL” Display: This typically indicates an out-of-range measurement or an open circuit. For diodes, it means the forward voltage is outside the 0.1V-0.9V range.
  • Device Not Powering On: Ensure the battery is charged. Connect the device to a power source using the Type-C cable and allow it to charge.

7.2 User Tips

  • For quick checks, use the auto-measurement mode. The device will intelligently identify the component type.
  • Utilize the data hold function (short press KEY1) to freeze readings for easier recording.
  • Experiment with different test frequencies for LCR measurements to get the most accurate results for various component types.
  • Regularly clean the gold-plated tips to maintain optimal contact and measurement accuracy.

8. Warranty and Support

8.1 Limited Warranty and Liability

This product is covered by a one-year warranty starting from the date of purchase. The warranty does not cover damages caused by accidents, negligence, misuse, modifications, contamination, or abnormal operating environments.

This manual is subject to change without prior notice. The information contained herein is considered accurate; if the user discovers any errors or omissions, please contact the manufacturer. The company shall not be held responsible for any accidents or hazards resulting from improper operation by the user. The functions described in this manual are not intended as justification for using the product for special purposes.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.