Sumry HMS1.5K

Contents

HMS 1.5k-12v AC Inverter User Manual

Model: HMS1.5K

Brand: Sumry

1. Introduction

This manual provides essential information for the safe and efficient operation of your Sumry HMS 1.5k-12v AC Inverter. This device is a configurable hybrid solar inverter designed to manage AC and solar input priority via LCD settings, suitable for various applications including air conditioning systems.

Please read this manual thoroughly before installation and operation. Keep it for future reference.

2. Product Overview

The HMS 1.5k-12v is a DC/AC inverter that integrates multiple functions to provide reliable power. It features a clear LCD display for monitoring and configuration.

Front-side view of the HMS 1.5k-12v AC Inverter

Figure 2.1: Front-side view of the HMS 1.5k-12v AC Inverter

Front view of the HMS 1.5k-12v AC Inverter

Figure 2.2: Front view of the HMS 1.5k-12v AC Inverter

Top-down view of the HMS 1.5k-12v AC Inverter showing connection ports

Figure 2.3: Top-down view showing connection ports

Bottom-up view of the HMS 1.5k-12v AC Inverter showing connection ports

Figure 2.4: Bottom-up view showing connection ports

Side view of the HMS 1.5k-12v AC Inverter

Figure 2.5: Side view of the HMS 1.5k-12v AC Inverter

Video 2.1: Product showcase for the Sumry HMS 1.5k-12v AC Inverter.

3. Safety Information

Please observe the following safety precautions during installation, operation, and maintenance:

  • Ensure all wiring is performed by qualified personnel.
  • Do not attempt to open or repair the inverter yourself. Refer to authorized service personnel.
  • Install the inverter in a well-ventilated area, away from flammable materials and moisture.
  • Ensure proper grounding of the unit.
  • Disconnect all power sources (AC, DC, and battery) before performing any maintenance or wiring.
  • Keep children away from the inverter.

4. Installation and Setup

The HMS 1.5k-12v inverter is designed for integration into a hybrid solar system. Proper installation is crucial for performance and safety.

4.1. Mounting the Inverter

  • Choose a suitable location that is dry, cool, and well-ventilated.
  • Mount the inverter vertically on a sturdy wall or surface, ensuring adequate clearance for airflow around the unit.
  • Use appropriate mounting hardware for the weight of the inverter.

4.2. Wiring Connections

All wiring should comply with local and national electrical codes. Refer to the connection ports shown in Figures 2.3 and 2.4.

  1. **Battery Connection**: Connect the battery bank to the designated battery terminals. Ensure correct polarity.
  2. **AC Input Connection**: Connect the utility grid or generator AC input to the AC input terminals.
  3. **Solar PV Input Connection**: Connect the solar panel array to the PV input terminals. Observe correct polarity and voltage limits.
  4. **AC Output Connection**: Connect your AC loads (e.g., air conditioner) to the AC output terminals.
  5. **Grounding**: Ensure the inverter chassis is properly grounded.
Diagram illustrating a hybrid solar inverter system for a home

Figure 4.1: Conceptual diagram of a hybrid solar inverter system for home use.

5. Operation

The inverter features an LCD display and control buttons for monitoring and setting operational parameters.

5.1. LCD Display Overview

The LCD display provides real-time status and operational data. Refer to the diagram below for an explanation of each indicator:

Detailed diagram of the LCD display and its indicators

Figure 5.1: LCD Display and Indicator Meanings

Table 5.1: LCD Display Indicators
No. Indicator Description
1PVPV input
2ACAC input
3INPUTBATTEMPInput voltage, input frequency, PV voltage, battery voltage, charger current
4Setting programsSetting programs
5Flashing / LightingFlashing with warning code / Lighting with fault code
6OUTPUTBATTLOADOutput voltage, output frequency, load percent, load in VA, load in watt and discharging current
7Load levelLoad level (25%, 100%)
8DC/AC InverterDC/AC inverter circuit is working
9Battery levelBattery level
10Charger circuitCharger circuit is working
11PV panel connectionUnit connects to the PV panel
12Mains connectionUnit connects to the mains
13BypassLoad is supplied by utility power
14Alarm disabledUnit alarm is disabled
15OverloadOverload

5.2. Configuring AC/Solar Input Priority

The inverter allows you to configure the input source priority (AC or Solar) via the LCD setting programs (Indicator 4). Consult the detailed programming section in the full product manual for specific steps. Typically, you can set the inverter to prioritize:

  • **Solar First**: Prioritizes solar power to supply loads and charge batteries. Utility power is used only when solar power is insufficient.
  • **Utility First**: Prioritizes utility power. Solar power is used as a backup or to charge batteries.
  • **SBU (Solar-Battery-Utility)**: Prioritizes solar, then battery, then utility.

Use the 'UP', 'DOWN', 'ESC', and 'ENTER' buttons on the control panel to navigate and select settings.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter.

  • **Cleaning**: Periodically clean the exterior of the inverter with a dry cloth. Ensure ventilation openings are free from dust and debris.
  • **Connections**: Check all wiring connections regularly to ensure they are tight and free from corrosion.
  • **Environment**: Ensure the installation environment remains within the specified temperature and humidity ranges.
  • **Battery Inspection**: If using external batteries, regularly inspect them for signs of damage, leakage, or corrosion.

Always disconnect all power sources before performing any maintenance.

7. Troubleshooting

If the inverter is not functioning correctly, refer to the LCD display for warning or fault codes (Indicator 5). Common issues and basic solutions are listed below:

Table 7.1: Basic Troubleshooting Guide
Problem Possible Cause Solution
No power outputBattery low, AC input disconnected, OverloadCheck battery voltage, verify AC input, reduce load
Warning/Fault code on LCDSpecific error condition (e.g., over-temperature, short circuit)Refer to the full manual for specific code meanings and solutions. Address the underlying issue.
Inverter not charging batteriesPV input insufficient, AC input unavailable, Charger circuit faultCheck solar panel connections and sunlight, verify AC input, contact support if charger fault persists.
Overload indicator (15) activeConnected load exceeds inverter capacityDisconnect non-essential loads. Ensure total load is within inverter's rated capacity.

For persistent issues or complex fault codes, please contact customer support.

8. Specifications

Table 8.1: Product Specifications
Feature Detail
Model NumberHMS1.5K
TypeDC/AC Inverters
DIY SuppliesElectrical
OriginMainland China
Dimensions (W x D x H)272mm x 100mm x 305mm
Package Weight20.5 kg
Output TypeSingle
High-concerned chemicalNone
ElectronicNo

9. User Tips

Based on general user experiences with similar inverters, consider the following tips for optimal performance:

  • **Ventilation is Key**: Always ensure the inverter has ample space for ventilation. Overheating can significantly reduce its lifespan and efficiency.
  • **Monitor LCD Regularly**: Periodically check the LCD display for any warning or fault codes, and monitor input/output parameters to ensure stable operation.
  • **Battery Health**: Maintain your battery bank according to the manufacturer's recommendations. Battery health directly impacts the inverter's performance and backup time.
  • **Load Management**: Avoid consistently running the inverter at its maximum capacity. Operating at 70-80% of its rated power can extend its life.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the contact details provided by your retailer or the manufacturer's official website.

Always provide your product model (HMS1.5K) and serial number when contacting support.


Documents and downloads