1. Introduction
The KP800 is a multi-functional Optical Time Domain Reflectometer (OTDR) designed for comprehensive testing and analysis of fiber optic networks and Ethernet cables. It integrates various essential functions including OTDR, Optical Power Meter (OPM), Visual Fault Locator (VFL), Laser Source (LS), Event Map, Loss Testing, and RJ45 Network Testing. Featuring a 4.3-inch touchable LCD screen and a robust design, the KP800 provides accurate measurements and efficient fault detection for field technicians and engineers.
2. Product List and Overview
2.1 What's in the Box

The standard package includes:
- OTDR host unit
- Testing report
- User manual
- Charging head
- Data cable
- SC adapter
- FC adapter (pre-installed on the machine)
- RJ45 remote adapter
- RJ45 receiver
- Portable bag
- Packaging box
2.2 Device Overview and Dimensions

The KP800 unit measures approximately 183mm x 107mm x 45mm and weighs about 480g (including battery). Key interfaces include:
- TF memory card slot
- RJ45 Network testing port
- USB interface
- LED indicator
- Charging port (Type-C)
- OPM port
- OTDR/LS port
- VFL port
3. Features

- Optical Time Domain Reflectometer (OTDR): Accurate length measurement, breakpoint finding, and dimming. Supports 100km range with 24/22dB dynamic range.
- Event Map: Visual representation of fiber events.
- Optical Power Meter (OPM): Supports 9 wavelengths and self-calibration of optical power.
- Visual Fault Locator (VFL): Large capacity storage, VFL range >10km.
- Stable Light Source (OLS): Output wavelength consistent with OTDR, supports CW/270/330/1000/2000Hz modes.
- Network Testing: Includes line tracing and line sequence testing for Ethernet cables.
- Loss Testing: Measures optical signal loss.
- LED Light: Integrated for illumination.
- 4.3-inch Touchable LCD Screen: Multi-touch, fast and sensitive response, colorful soft light screen, high-definition display.
- Active Fiber Test: Optional feature for live fiber testing.
- Long Battery Life: Built-in 5200mAh lithium battery, charged via Type-C interface.
4. Setup
4.1 Charging the Device

Before first use, fully charge the KP800. Connect the provided charging head and data cable to the Type-C charging port on the device. The charging indicator will show the charging status. A full charge ensures optimal performance and battery life.
4.2 Installing Fiber Optic Adapters
The KP800 comes with an FC adapter pre-installed. For SC fiber connections, replace the FC adapter with the provided SC adapter. Ensure the adapter is securely fastened to prevent inaccurate readings or damage.
4.3 Powering On/Off
Press and hold the power button (usually located below the navigation buttons) for a few seconds to turn the device on or off. The LCD screen will illuminate upon successful power-on.
5. Operating Instructions
5.1 Navigating the Interface

The KP800 features a 4.3-inch touch screen for easy navigation. You can also use the physical buttons:
- OK: Confirm selection or enter a menu.
- SETUP: Access settings for the current function.
- ESC: Go back to the previous screen or exit a function.
- M/A/Arrow Buttons: Navigate through menus and adjust parameters.
5.2 OTDR Function

The OTDR function is used for measuring fiber length, locating breakpoints, and analyzing signal attenuation. It supports an optional active fiber test.
- From the main menu, tap on the 'OTDR' icon.
- Connect the fiber optic cable to the OTDR/LS port using the appropriate SC or FC adapter.
- In the OTDR settings, configure parameters such as wavelength (e.g., 1310nm, 1550nm), pulse width, and measurement range according to your testing requirements.
- Initiate the test. The device will perform automatic measurement and analysis, displaying the trace graph and event list.
- For active fiber testing, ensure the 'Active Fiber Test' option is enabled in the settings (if available for your model).
5.3 OPM (Optical Power Meter) and VFL (Visual Fault Locator)

These functions are crucial for measuring optical power and visually locating fiber faults.
- From the main menu, tap on the 'OPM' or 'VFL' icon.
- For OPM: Connect the fiber to the OPM port. Select the desired calibration wavelength (e.g., 1310nm, 1550nm). The device will display the optical power in dBm.
- For VFL: Connect the fiber to the VFL port. Activate the VFL function. A red laser light will be emitted, allowing you to visually identify breaks, bends, or poor connections in the fiber up to 10km.
5.4 LS (Laser Source) Function

The LS function provides a stable light source for various fiber optic tests.
- From the main menu, tap on the 'Laser Source' icon.
- Connect the fiber to the OTDR/LS port.
- Select the desired output wavelength (consistent with OTDR) and modulation mode (CW, 270Hz, 330Hz, 1KHz, 2KHz).
- WARNING: This device uses a Class 3B laser. Avoid direct eye exposure to the laser beam, as it can cause severe eye injury. Always use appropriate safety precautions.
5.5 RJ45 Network Test

The KP800 can test the line sequence and length of RJ45 network cables.
- From the main menu, tap on the 'RJ45 Test' or 'RJ45 Tracker' icon.
- Connect one end of the network cable to the RJ45 Network testing port on the KP800.
- Connect the other end of the network cable to the RJ45 remote adapter, and then connect the RJ45 receiver to the remote adapter.
- Initiate the test. The device will display the wiring sequence and cable length.
6. Maintenance
6.1 Cleaning Optical Ports and Connectors
Regular cleaning of optical ports and connectors is essential for accurate measurements and to prevent damage. Use only lint-free optical cleaning wipes and approved optical cleaning solutions. Never use abrasive materials or solvents.
6.2 Battery Care
To maximize battery life, charge the device regularly and avoid completely draining the battery. If storing the device for an extended period, ensure it is charged to approximately 50% and recharge every few months.
6.3 Storage
Store the KP800 in its portable bag in a dry, cool, and dust-free environment. Avoid exposure to extreme temperatures, direct sunlight, or high humidity.
7. Troubleshooting
- Device not powering on: Ensure the battery is charged. Connect the device to the charger and try again.
- Inaccurate fiber optic measurements: Clean all fiber optic connectors and ports thoroughly. Verify that the correct wavelength and pulse width settings are selected for the fiber type being tested.
- No VFL light: Check if the VFL function is activated in the menu. Ensure the fiber is properly connected to the VFL port.
- RJ45 network test failure: Confirm that the network cable is correctly connected to both the KP800's RJ45 port and the remote adapter/receiver. Check for cable damage.
- Touch screen unresponsive: Try restarting the device. If the issue persists, contact support.
8. Specifications

| Feature | Specification |
|---|---|
| Model | KP800 |
| Wavelength | 1310/1550nm, 1310nm, 1550nm, 1610nm, 1625nm, 1650nm |
| Dynamic range | 24/22dB (1310/1550nm), 24dB (1310nm), 22dB (1550nm, 1610nm, 1625nm, 1650nm) |
| Fiber type | G.652D |
| Event blind area | 1.5m |
| Attenuation blind zone | 7m |
| Measuring range | 100m/500m/1km/2km/5km/10km/20km/40km/60km/100km |
| Pulse width | 5ns/10ns/20ns/50ns/100ns/275ns/500ns/1us/2us/5us/10us |
| Measurement accuracy | ±(1m+sampling interval+0.005%X measurement range) |
| Linearity | ±0.2dB/dB |
| Number of sampling points | Maximum 20000 |
| Sampling resolution | 20cm-8m |
| Loss resolution | 0.001dB |
| Range resolution | 0.001m |
| Refractive index | 1.0000-2.0000 |
| Reflection accuracy | ±3dB |
| File format | Standard SOR file format |
| Laser safety level | Class 3B |
| Working environment temperature | -10℃ ~ 50℃ |
| Storage environment temperature | -40℃ ~ 70℃ |
| Humidity | 0-90% Non condensing |
| Size/weight | 183x107x45mm / 480g (including battery) |
| OPM (Optical Power Meter) | |
| Calibration wavelength | 850/1270/1300/1310/1490/1550/1577/1625/1650nm |
| Measurement range | -50~+26dBm |
| Frequency identification | 270Hz/330Hz/1KHz/2KHz |
| Uncertainty | ±5% |
| Optical connector | Universal Head FC/SC/ST |
| LS (Laser Source) | |
| Wavelength | Same OTDR output wavelength |
| Laser type | FP-LD |
| Output power | -5dBm (adjustable) |
| Uncertainty | ±5% |
| Optical connector | FC/SC/ST (Interchangeable) |
| Other | |
| VFL | ≥10km |
| Network cable test | Yes |
| Line sequence/line finding | Yes |
| Battery | 5200mAh / 3.7V |
| Charger | Type C charging |
| Save | Internal ≥1000, external support SD card |
9. User Tips
- Always clean fiber optic connectors before use to ensure accurate readings and prevent damage to the device's optical ports.
- For network cable testing, ensure the remote module is securely connected to the far end of the cable for proper length and sequence detection.
- Utilize the Event Map feature for quick visual identification of fiber issues, which can save significant troubleshooting time.
- When using the VFL, always look away from the fiber end to avoid direct eye exposure to the laser.
- Regularly back up your test data from the internal memory to an external SD card to prevent data loss.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase records for reference.