1. Introduction
The GEYA 4P VA5 Overvoltage & Undervoltage Protector is a sophisticated device designed to safeguard electrical circuits in both home and industrial environments. It provides comprehensive protection against voltage fluctuations, including overvoltage, undervoltage, and phase sequence errors. This manual provides essential information for the safe and effective installation, operation, and maintenance of your device.

2. Safety Precautions
Please read and adhere to the following safety guidelines to prevent injury or damage to the device:
- Professional Installation: This equipment must be installed by qualified professionals.
- Power Disconnection: Before any operation or maintenance, disconnect all power supplies to the device and ensure no terminal is live.
- Terminal Verification: Always verify that terminals are properly connected according to the wiring diagram.
- No Disassembly or Repair: Do not attempt to disassemble or repair the equipment yourself. Refer to qualified service personnel.
- Environmental Conditions: Do not use the equipment in places that may be corroded by gas, exposed to strong sunlight, or rain.
3. Installation and Wiring
The GEYA 4P VA5 Protector is designed for DIN rail mounting. Ensure adequate space for ventilation and access to terminals.
3.1. Product Dimensions

3.2. Wiring Diagram
Follow the diagram below for correct power and load connections. Ensure all connections are secure and properly insulated.

- Power Input: Connect the neutral (N) and live phases (L1, L2, L3) from your power source to the corresponding top terminals.
- Load Output: Connect the neutral (N) and live phases (L1, L2, L3) of your load to the corresponding bottom terminals.
4. Operation
The device features a digital display and control buttons for monitoring and setting parameters.
4.1. Display Panel

The display shows real-time voltage (V) and current (A) for each phase (L1, L2, L3). The control buttons are:
- SET: Enters/confirms settings.
- UP/DOWN Arrows: Adjusts parameter values.
- Hand Switch: Manual control (if applicable).
- Menu Key: Navigates through menu options.
4.2. Product Status Indicators
- Normal Operation: The operating voltage and current values are displayed.
- Fault Detection: If a fault (voltage or current) is detected, the output relay turns off, and the fault indicating LED lights up.
- Voltage Failure: If the input voltage trips back to the hysteresis value after a voltage failure, the relay will automatically reset/start the delay count, and the current value will flash.
- Phase Sequence Error: If a phase fault occurs, 'L1-L2-L3' will be displayed, and the protector will disconnect from the output power supply.
- Continuous Overcurrent: If a continuous overcurrent fault is detected, 'OFF' will be displayed. Disconnect the overloaded device and manually reset the protector.
4.3. Setup Menu (P-1 to P-15)
The device allows for customization of various protection parameters. Access the setup menu using the 'SET' and 'Menu' keys, and adjust values with the UP/DOWN arrows.
| Parameter Code | Description | Adjustable Range |
|---|---|---|
| P-1 | Power-on delay time | 1s - 600s |
| P-2 | Protection recovery delay | 1s - 600s |
| P-3 | Overvoltage protection value | 230V - 300V |
| P-4 | Overvoltage recovery value | 265V - 295V |
| P-5 | Undervoltage protection value | 170V - 210V |
| P-6 | Undervoltage recovery value | 175V - 215V |
| P-7 | Voltage protection action delay | 0.1s - 10s |
| P-8 | Three-phase voltage unbalance value | 50V - 100V |
| P-9 | Three-phase voltage unbalance recovery value | 20V - 99V |
| P-10 | Three-phase voltage calibration | -9.5V - 9.5V |
| P-11 | Phase-sequence switch | On/Off |
| P-12 | Overcurrent protection value | 63A, 100A |
| P-13 | Overcurrent protection action time | 0.5s - 10s |
| P-14 | Continuous overcurrent protection | Off / 0-20 |
| P-15 | Three-phase current error calibration | -9.5A - 9.5A |
5. Maintenance
The GEYA 4P VA5 Protector is designed for long-term, reliable operation with minimal maintenance. To ensure optimal performance and longevity:
- Cleaning: Keep the device clean and free from dust. Use a dry, soft cloth for cleaning.
- Environment: Ensure the operating environment remains within specified temperature and humidity ranges, and free from corrosive gases.
- No User Serviceable Parts: The device contains no user-serviceable parts. Any internal issues should be addressed by qualified technicians.
6. Troubleshooting
If the device is not functioning as expected, refer to the following common issues and solutions:
| Problem | Indication | Possible Cause | Solution |
|---|---|---|---|
| Device trips, fault LED on | Output relay OFF, fault LED ON | Overvoltage, undervoltage, or overcurrent fault detected. | Check input voltage/current. Device will automatically reset after conditions normalize (or manual reset for overcurrent). |
| Voltage failure | Input voltage trips, current value flashes | Input voltage dropped below undervoltage threshold. | Device will automatically reset once voltage recovers to hysteresis value. |
| Phase fault | 'L1-L2-L3' displayed, output disconnected | Phase sequence error or phase loss. | Check phase connections and power supply. |
| Continuous overcurrent | 'OFF' displayed | Load drawing excessive current. | Disconnect overloaded device. Manually reset the protector. |
7. Specifications
Below are the technical specifications for the GEYA 4P VA5 Overvoltage & Undervoltage Protector:
| Feature | Specification |
|---|---|
| Rated Supply Voltage | AC380V |
| Operating Voltage Range | AC120V-300V |
| Rated Frequency | 40/50/60/70Hz |
| Lag (Overvoltage & Asymmetry) | 5V |
| Lag (Undervoltage) | 5V |
| Asymmetric Delay | 10s |
| Voltage Measurement Accuracy | ≤2% (On the whole spectrum) |
| Rated Insulation Voltage | 450V |
| Output Contact | 3NO |
| Electrical Life | 10⁵ cycles |
| Mechanical Life | 10⁵ cycles |
| Protection Class | IP20 |
| Pollution Degree | 3 |
| Altitude | <2000m |
| Operating Temperature | -5℃ to 40℃ |
| Humidity | ≤50% or 40℃ (Condensation free) |
| Storage Temperature | -25℃ to 55℃ |
| Type | Moulded Case, Circuit Breaker |
| Is Smart Device | Yes |
| Certification | CE |
| Rated Current Options | 63A, 100A |
| Package Dimensions (L x W x H) | 10cm x 8cm x 5cm |
| Package Weight | 0.5kg |
8. User Tips
- Voltage Compatibility: While the device is rated for AC380V, always verify the specific voltage parameters (P-3 to P-6) are set correctly for your local grid, especially if operating on a 400V system. Consult a professional electrician if unsure.
- Parameter Customization: Take advantage of the extensive setup menu (P-1 to P-15) to fine-tune protection thresholds and delays according to your specific application requirements.
9. Warranty and Support
For detailed warranty information, technical support, or further inquiries, please refer to the official documentation or contact GEYA customer service.
An electronic version of the user manual (PDF) is available for more in-depth information. You can typically find this document on the manufacturer's website or by searching for the product model number.
Reference: User manual (PDF)