FDIK 5KW Diesel Air Heater

Contents

FDIK 5KW Diesel Air Heater User Manual

Model: 5KW Diesel Air Heater

Introduction

This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your FDIK 5KW Diesel Air Heater. Please read this manual thoroughly before installation and use, and keep it for future reference.

FDIK 5KW Diesel Air Heater with 12V and 220V power options, showing the main unit, LCD display, and remote control.
FDIK 5KW Diesel Air Heater, designed for versatile heating needs.

The FDIK Diesel Air Heater operates by drawing in cold air, passing it through a heated aluminum body, and then blowing out hot air. This process efficiently converts diesel combustion into warm air, providing warmth for various applications.

Safety Information

Always observe the following safety precautions to prevent injury or damage:

  • Ensure proper ventilation when operating the heater to prevent carbon monoxide buildup.
  • Do not block the air inlet or outlet. Maintain clear space around the unit.
  • Use only clean diesel fuel. Never use gasoline or other volatile fuels.
  • Keep flammable materials (e.g., curtains, paper, chemicals) at a safe distance from the heater.
  • Ensure all electrical connections are secure and correct (Red for positive, Black for negative). Incorrect wiring can cause damage or fire.
  • Do not operate the heater if any part is damaged, malfunctioning, or if there are visible leaks.
  • Keep the heater out of reach of children and pets.
  • Never leave the heater unattended during operation.

Product Components

The FDIK Diesel Air Heater typically includes the following components:

FDIK T7 model components including the heater unit, remote control, LCD control panel, clamps, 220V power adapter, user manual, and exhaust pipe.
Typical components for FDIK T7 model. The T6 model has similar components.
  • Heater Unit (with integrated 3.5L fuel tank)
  • LCD Control Panel (e.g., C33 Six-button Switch)
  • Remote Control
  • 12V/24V Power Cables
  • 220V Power Adapter (for models supporting 220V AC operation)
  • Exhaust Pipe and Muffler
  • Air Inlet Pipe
  • Hot Air Outlet Pipe
  • Clamps and Fasteners for installation
  • User Manual

The heater features a durable metal case for strong impact resistance, a convenient handle for portability, and clearly marked power interfaces (Red terminal for positive, Black terminal for negative).

Diagram showing the metal case, portability handle, and power interface with red for positive and black for negative terminals.
Key features: Metal case, portability, and power interface details.

Setup and Installation

Before operating the heater, ensure it is properly set up and all connections are secure.

1. Placement

  • Place the heater on a stable, level, and non-flammable surface.
  • Ensure adequate clearance (at least 30cm) around the air inlet and outlet for proper airflow and to prevent overheating.
  • Avoid placing the heater in extremely confined spaces.

2. Fueling

  • Open the fuel cap and fill the integrated 3.5L fuel tank with clean diesel fuel.
  • Do not overfill the tank.
  • Ensure the fuel cap is securely closed after filling.

3. Electrical Connection

  • For 12V/24V DC operation: Connect the red power cable to the positive (+) terminal and the black power cable to the negative (-) terminal of your 12V or 24V DC power source. Ensure connections are tight and secure.
  • For 220V AC operation: Use the provided 220V power adapter. Connect the heater's DC input to the adapter, then plug the adapter into a standard 220V AC wall outlet.
FDIK heater connected to a 220V wall outlet using the provided 220V adapter.
Connecting the heater to a 220V power source using the adapter.

4. Exhaust System

  • Attach the exhaust pipe securely to the heater's exhaust port.
  • Route the exhaust pipe and muffler to safely vent combustion gases outside the heated area. Ensure the exhaust is not directed towards flammable materials or enclosed spaces.
  • Ensure all exhaust connections are tight and free from leaks.

Operating Instructions (C33 Six-button Switch)

The heater is controlled via the LCD control panel (C33 Six-button Switch) or the remote control.

FDIK T6 model components including the heater unit, remote control, LCD control panel, clamps, 220V power adapter, user manual, and exhaust pipe.
FDIK T6 model showing the LCD control panel and remote control.

1. Power On/Off

  • To turn on: Press and hold the power button on the control panel for 3 seconds.
  • To turn off: Press and hold the power button on the control panel for 3 seconds.

2. Gear Adjustment

  • Use the upward and downward arrow buttons on the control panel to adjust the heating gears, typically from P1 to P5.

3. Remote Control Matching

  • Method 1: While the heater is off, press the upward and downward arrow buttons on the control panel simultaneously. The screen will display a 10-second countdown. During this countdown, press any button on the remote control to match it with the heater.
  • Method 2: Long press the middle turn on button (on the control panel) until "r1" is displayed, then release the button. Press any button on the remote control within 10 seconds to successfully match.
Remote control being used to operate the heater in a snowy outdoor setting, indicating a maximum range of 30 meters.
The remote control offers convenient operation with a range of up to 30 meters under barrier-free conditions.

4. Timing Function

  • Long press the timing button on the control panel. "00:00" will be displayed on the screen.
  • Use the upward and downward arrow buttons to set the desired countdown time (XX:XX). The heater will automatically turn on after this duration.
  • The power on/off button is used to select the number for timing. For example, "12:15" represents that the heater will turn on after 12 hours and 15 minutes.
  • To cancel the timing, press the timing button again.

5. Viewing Information

  • Press the view button on the control panel to cycle through and display the ambient temperature, aluminum body temperature, and current voltage.

6. Advanced Functions (Long press the middle button in ON/OFF state)

  • Normal Turn On: Long press the middle turn on button for 5 seconds. The first display will show "on", indicating normal turn on.
  • Automatic Pump Oil Start: Long press the middle turn on button for 5 seconds. The second display will show "Po". Release the button. Oil will be pumped after the ignition plug is preheated for 1 minute. Once the oil tube is full, the machine will automatically ignite for normal combustion. If the oil tube is long and not full at once, the fan will continue to work, "Po" will flash, and you can press the button again to restart the oil pump for the second time.
  • Ventilation Function: Long press the middle turn on button. The third display will show "Fn". Release the button. The screen will display F1-F5, which is adjustable. This function provides ventilation for the cab.
  • Remote Control Manual Oil Pump: Long press the middle turn on button. The fifth display will show "rp". Release the button. "20" will be displayed, indicating this function will close after 20 minutes. Turn on the remote control to pump oil and turn off the remote control to stop.

    Note:

    • This function does not support ignition. Observe the oil in the tubing at all times and stop pumping when full.
    • After using this function, the remote control must be re-matched.

Maintenance

Regular maintenance ensures optimal performance, efficiency, and longevity of your heater.

1. Cleaning

  • Periodically clean the exterior of the heater with a soft, damp cloth.
  • Ensure air inlets and outlets are free from dust, debris, and obstructions.
  • Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the unit's finish or internal components.

2. Fuel System

  • Always use clean diesel fuel to prevent clogging of the fuel lines, fuel pump, and combustion chamber.
  • Regularly inspect fuel lines for any signs of leaks, cracks, or damage. Replace damaged lines immediately.

3. Internal Components

The heater's internal structure includes a heating zone, overheat protection device, flame retardant impeller, control box, air fan, glow plug, combustion chamber, and motor assembly. While most internal components are not user-serviceable, understanding their function can help in troubleshooting.

Exploded view diagram of the FDIK heater showing internal components like the heating zone, overheat protection device, flame retardant impeller, control box, air fan, glow plug, combustion chamber, and motor assembly.
Internal components of the FDIK Diesel Air Heater.

Troubleshooting (FDIK C33 Fault Code Manual)

If your heater encounters an issue, the LCD control panel may display a fault code. Refer to the table below for common fault codes and their solutions. If the problem persists after attempting the suggested solutions, contact customer support.

Error Code Problem Solution
0 Panel failure Replace the control panel.
1 Ignition failure failed
  • Check if the fuel tank is low or empty.
  • Check if the oil pump is stuck or abnormal.
  • Verify the oil circuit for correctness, absence of air bubbles, and continuous oil supply.
  • Check for poor power supply or fuel quality issues.
2 Flame out
  • Check for oil path leaks or air bubbles causing discontinuous oil supply.
  • Check if the fuel tank is low, oil pump is abnormal, or fuel quality is poor.
3 Incorrect power supply voltage (Under-voltage or over-voltage)
  • Ensure the power cord is correctly connected and voltage matches the machine's requirements (12V, 24V, or 220V).
  • Check for securely inserted connectors and good contact.
  • Check for poor contact inside the fuse box.
  • Verify panel configuration matches vehicle's voltage.
  • Avoid substandard electrical cables or extra connections.
  • Ensure the power converter (if used) supplies enough current and stable output voltage.
6 Intake air over-temperature
  • The room temperature is too high.
  • Check for blocked air outlet/inlet.
  • Ensure sufficient installation space around the heater.
7 Oil pump problem
  • Check if the oil pump is properly connected, or if the connection line is open or short-circuited.
  • Ensure the 5-pin socket panel is properly plugged in.
  • Check for disconnection in the oil pump circuit.
8 Fan (motor) Problem
  • Check if fan blades are stuck.
  • Check for incorrect speed (motor repeats 3 times to report fault).
  • Internal fault of the motor.
  • Ensure the motor socket is properly plugged in.
9 Ignition shorted plug
  • Check for short-circuited ignition pin or reversed connection wire.
  • Check for insulation damage or leakage at the ignition plug.
10 Overheat
  • Remove obstacles to air circulation or obstructed air ducts.
  • Ensure sufficient installation space.
  • Check for incorrect connection to an oil pump with a large flow rate.
  • Check for oil pump check valve leakage.
11 Overheating sensor failure Replace the overheat sensor.
12 Ignition plug open circuit
  • Check for poor contact of the ignition plug connector.
  • Replace burned out ignition plug.

Specifications

Feature Detail
Brand Name FDIK
Item Type Heating & Fans
Fuel Diesel
Switch Type LCD Switch (C33 Six-button)
Voltage Options 12V/24V DC, 220V AC (with adapter)
Heating Space Up to 20 m²
Shell Material Metal
Working Temperature -40°C to 40°C
Fuel Tank Capacity 3.5L
Fuel Consumption 0.15-0.55 L/H (depending on temperature/power)
Remote Control Distance Up to 30m (under barrier-free conditions)
Dimensions (approx.) 365mm (Length) x 250mm (Width) x 260mm (Height)
Diagram showing the dimensions of the FDIK Air Heater T6 model: 365mm length, 250mm width, 260mm height, along with key specifications like voltage, heating space, shell material, switch type, fuel, and working temperature.
Dimensions and key specifications of the FDIK Air Heater T6.

User Tips

  • Exhaust System: Always ensure the exhaust pipe is properly installed and vents combustion gases completely outside the heated area to prevent carbon monoxide buildup.
  • Fuel Consumption: Be aware that the heater's fuel consumption can vary significantly (0.15-0.55 L/H) depending on the selected power level and the ambient temperature. Adjust settings as needed for efficiency.
  • Remote Control Range: The remote control works best under barrier-free conditions, with a maximum range of 30 meters. Obstacles can reduce this range.

Warranty and Support

For warranty information, technical support, or service inquiries, please contact FDIK INTL Store directly through the platform where the product was purchased. Refer to your purchase documentation for specific warranty terms and contact details.

A detailed user manual in PDF format is available for download. This document contains comprehensive instructions and diagrams for installation, operation, and maintenance.

PDF Manual Reference: View User Manual (PDF)

© 2023 FDIK INTL Store. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.