LAUNCH X431 O2-2

Contents

LAUNCH X431 O2-2 Scope Box Oscilloscope

User Instruction Manual

1. Product Overview

The LAUNCH O2-2 Scopebox is a versatile and easy-to-use add-on module designed to detect high-level faults in various automotive electrical components such as sensors, actuators, and circuits. It integrates with LAUNCH X-431 series scan tools via the O2-2 application to provide accurate and conclusive diagnostic capabilities.

Video showcasing the LAUNCH X431 O2-2 Scope Box Oscilloscope and its components.

2. Setup

2.1 Unboxing and Package Contents

Carefully unpack all items from the box. Please verify that all components listed below are present and in good condition.

LAUNCH X431 O2-2 Scope Box Oscilloscope with all included accessories and carrying case.

LAUNCH X431 O2-2 Scope Box Oscilloscope with all included accessories and carrying case.

Detailed view of all accessories included with the LAUNCH X431 O2-2 Scope Box Oscilloscope, including test lines, probes, clips, attenuators, and user manual.

Detailed view of all accessories included with the LAUNCH X431 O2-2 Scope Box Oscilloscope.

  • 1pc x LAUNCH O2-2 Main Unit
  • 4pcs x HT30 Test Lines
  • 1pc x HT25 Secondary Ignition Pick-up Line
  • 1pc x Battery Clip Cable
  • 1pc x USB Cable
  • 2pcs x HT201 Attenuator
  • 20pcs x Piercing Needles
  • 2 pairs x Multimeter Probes
  • 2 pairs x Crocodile Clips
  • 5pcs x Colored 4mm Female Probes
  • 4pcs x Clipper Fuses (5*20mm)
  • 2pcs x Screw Head
  • 1pc x User Manual
  • 1pc x Color Label
  • 1pc x Packing List

2.2 Physical Overview

Familiarize yourself with the ports and indicators on the device:

Top, front, and bottom views of the LAUNCH X431 O2-2 Scope Box Oscilloscope, highlighting the standard probe calibration connector, channels (CH1-CH4), status indicator, USB interface, and DC IN charging port.

Top, front, and bottom views of the LAUNCH X431 O2-2 Scope Box Oscilloscope.

  • Standard Probe Calibration Connector: For probe calibration.
  • CH1, CH2, CH3, CH4: Four input channels for connecting test leads.
  • Status Indicator: Provides device status feedback.
  • USB Interface: For connecting to a PC or compatible LAUNCH scan tool.
  • DC IN Charging Port: For power input.

2.3 Initial Connection

  1. Power On: Connect the device to a power source using the DC IN charging port.
  2. Connect to PC/Scan Tool: Use the provided USB cable to connect the O2-2 Scope Box to your computer or a compatible LAUNCH X-431 series scan tool.
  3. Software Installation: Ensure the necessary O2-2 application software is installed on your PC or LAUNCH scan tool. Refer to the software's documentation for installation instructions.

3. Operating Instructions

3.1 General Operation

  • Waveform Recording & Playback: The device can record and play back high-resolution waveform data for detailed analysis.
  • One-Key Capture: Utilize the one-key enable function to quickly capture specific waveforms, improving efficiency.
  • Automatic Measurements: Access up to 23 variants of automatic measurements displayed on a single screen for easy switching and analysis.
  • Virtual Keyboard Input: Input names and characters directly using the virtual keyboard for streamlined operation.
  • Zoom Function: Use the zoom in/out feature to review precise details of waveforms.
  • Customizable Settings: Personal system settings can be saved as configuration files for future viewing and consistent analysis.
  • Self-Calibration: The self-calibration function optimizes the oscilloscope signal path for maximum measurement accuracy.
  • Waveform Math Operations: Perform advanced waveform analysis using math operations such as addition, subtraction, multiplication, and FFT functions.

3.2 Automotive Tests

The LAUNCH O2-2 supports multiple automotive tests, including:

  • Circuit testing
  • Sensor analysis
  • Actuator testing
  • Ignition system tests

3.3 Software Integration

The O2-2 Scope Box integrates seamlessly with LAUNCH X-431 series scan tools via the dedicated O2-2 application. Launch the application on your scan tool or PC to begin diagnostics and utilize the full functionality of the oscilloscope.

4. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures. Refer to the specifications for recommended storage temperature.
  • Cable Care: Inspect cables and connectors regularly for any signs of wear or damage. Replace damaged components immediately.

5. Troubleshooting

If you encounter any issues with your LAUNCH X431 O2-2 Scope Box, please consider the following general steps:

  • Ensure all cables are securely connected.
  • Verify the device is receiving power.
  • Check the software application for any error messages or updates.
  • Consult the official user manual (PDF available at this link) for detailed troubleshooting guides.

6. Specifications

FeatureSpecification
Channels4
Bandwidth100MHz
Rising Time≤3.5ns (typical)
Max. Sample Rate1Gbps (for four channels)
Input Impedance1MΩ±1.5%
Storage Depth50M (for four channels)
Sample Bit8bit
Horizontal Precision3%
Horizontal Scale5mV~10V
Horizontal Offset Range± 2.5V (probe switch “x1”, <500mV/div), ±120V (probe switch “x1”, ≥500mV/div)
InvertSupport
CouplingDC, AC
Timebase50ns~1ks (1 channel), 10 200ns~1ks (4 channels)
Timebase Precision20ppm
Acquisition ModeNormal
Line DecodingCAN, LIN
Trigger TypeEdge, Pulse width
Trigger ModeNormal, Auto and Single SEQ
Trigger CouplingDC, Noise rejection
DisplayYT, Zoom, Roll
Roll Mode200ms/div~1000s/div
Automotive TestsCircuits, sensor, actuators, ignition
Working Temperature0℃~50℃
Storage Temperature-30℃~70℃

7. User Tips

No specific user tips were available from the provided data (reviews or Q&A content).

8. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your original point of purchase or the official LAUNCH customer support channels. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.