Fangling F2500A F2600

Contents

Fangling F2500A / F2600 CNC Plasma Flame Gantry Cutting Machine Controller User Manual

2-Axis Control Operating System

Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Fangling F2500A and F2600 series CNC Plasma Flame Gantry Cutting Machine Controllers. These 2-axis control operating systems are designed for precision cutting applications, offering advanced features for efficient and reliable performance in industrial environments. Please read this manual thoroughly before operating the device to ensure safe and optimal use.

Specifications

Technical Indicators

  • Number of Control Axes: 2-axis linkage
  • Control Accuracy: ±0.001mm
  • Coordinate Range: ±99999.99mm
  • Maximum Pulse Frequency: 200KHz
  • Maximum Operating Speed: 15 m/min
  • Maximum Number of Program Lines: 80,000 lines
  • Maximum Single Program Size: 4MB
  • Time Resolution: 10ms
  • System Power Supply: DC 24V DC input, power greater than 80W
  • System Working Environment: Temperature -10°C to +60°C; Relative humidity 0-95% (non-condensing)
  • Maximum Driving Motor Power for Arc Voltage Adjustment: 45W (Note: Only with T system). Up to 200W can be selected for higher power requirements.

Hardware Configuration

  • Display: F2500A features a 15-inch industrial VGA high-brightness LCD screen. The F2600 model and general product line may feature a 17-inch screen.
  • Memory: 64MB SDRAM
  • User Program Space: 256MB
  • Main Frequency: 400MHz system main frequency
  • USB Interface: Front-mounted USB1.1 interface, supports at least 16GB USB flash drives for data transfer.
  • Keyboard: PCB film keyboard
  • Chassis: All-steel structure, completely shielded for electromagnetic radiation prevention, anti-interference, and anti-static protection.

System Interface

The controller is equipped with various interfaces for seamless integration and operation:

  • Motor Drive Interface: DB15 core male connector for two-axis motor drive.
  • Output Interface: DB25-core female connector with 16 optically isolated outputs, maximum reverse current 300mA.
  • Input Interface: DB25-core male connector with 16 optically isolated inputs, maximum input current 300mA.
  • Serial Port: Optional standard DB9 core male serial port RS232 interface.
Rear view of the CNC controller showing various input/output ports and warning labels.
Figure 1: Rear panel showing input/output ports.
Front view of the CNC controller with a partial view of the rear connections and warning labels.
Figure 2: Controller with visible rear connections and warning labels.

Interface Pinout and Dimensions

Refer to the following tables and diagrams for detailed pin assignments and physical dimensions for installation.

Detailed wiring diagram and interface pinout tables for Input, Output, and Motor connections, including dimension drawings.
Figure 3: Input, Output, and Motor Interface Pinout with Dimensions.

Important Warnings:

  • Please use 24V DC power supply.
  • Do not open the unit without proper authorization or it may void the warranty.
  • Install and wire the case according to the manual.
  • Ensure firm grounding for all connections.
  • Do not open the unit within 5 minutes after power off due to potential residual charge.

Setup and Installation

Proper installation is crucial for the safe and effective operation of your CNC controller. Ensure all connections are secure and follow safety guidelines.

Physical Installation

  1. Mount the controller securely within your gantry cutting machine's control panel, ensuring adequate ventilation. Refer to the dimension diagrams in Figure 3 for precise fitting.
  2. Ensure the chassis is firmly grounded to prevent electromagnetic interference and static discharge.

Wiring Connections

Connect the necessary cables according to the interface pinout diagrams provided in Figure 3.

  • Power Supply: Connect a DC 24V power supply (greater than 80W) to the designated power input terminal.
  • Motor Connections: Connect your two-axis motors to the DB15 core male motor drive interface.
  • Input/Output: Connect external devices and sensors to the DB25-core input and output connectors as required by your cutting system configuration.
  • USB: The front USB port is for transferring cutting codes.
  • RS232: If using serial communication, connect to the optional DB9 RS232 port.
Front view of the CNC controller with power cables connected.
Figure 4: Controller with power and data cables connected.

Operating Instructions

The Fangling F2500A/F2600 controller offers intuitive operation for various cutting tasks.

Basic Operation Flow

  1. Power On: Ensure all connections are secure, then apply DC 24V power. The system will boot up and display the main interface.
  2. Load Program: Use the front USB interface to transfer cutting codes (G-code files) to the controller's user program space.
  3. Select Cutting Mode: Choose from oxygen gas, plasma, powder spraying, or demonstration modes as appropriate for your material and process.
  4. Parameter Setup: Adjust cutting parameters such as speed, height, preheating times, and perforation settings. The system supports automatic height adjustment for oxygen gas and arc voltage feedback for plasma.
  5. Graphic Selection: Utilize the built-in library of up to 48 standard graphics (see Figure 6) or load custom designs. The system allows dynamic/static processing graphics display, zoom, and dynamic tracking of cutting points.
  6. Positioning: Manually select the starting line or piercing point for your cut. The system supports laser pointing for precise alignment.
  7. Start Cutting: Initiate the cutting process. The controller will execute the program, automatically limiting speed at corners to prevent overheating on thicker plates.
  8. Monitor Progress: Observe the cutting process on the display, which provides dynamic tracking of the cutting point.
  9. Power Off: After operation, power off the system. Wait at least 5 minutes before opening the chassis for any reason.
Front view of the CNC controller displaying the main operating interface with a cutting pattern.
Figure 5: Main operating interface displaying a cutting pattern.
Diagram showcasing the 48 standard graphic libraries available for cutting.
Figure 6: Standard Graphic Libraries for quick cutting.

Advanced Features

  • Dynamic Perforation: Supports plasma dynamic perforation to protect the torch head during operation (see Figure 7).
  • Edge Cutting: Reduces preheating time for thicker steel plates by starting cuts from the edge.
  • Offset Cutting: This function helps avoid material waste caused by nesting calculation errors.
  • Breakpoint Protection: Features power-off and breakpoint protection memory, allowing resumption of operations after interruptions.
  • Remote Control: Supports P2P mode or BCD (8421) and serial port RS232 remote control.
Illustration of plasma cutting in progress, demonstrating dynamic perforation.
Figure 7: Plasma dynamic perforation in action.

Maintenance

Regular maintenance ensures the longevity and optimal performance of your controller.

  • Software Updates: The system supports U disk upgrade method, providing lifetime upgrade service. Regularly check for and apply software updates to enhance functionality and fix bugs. (See Figure 8 for U disk upgrade method).
  • Parameter Backup: Periodically back up your system parameters and critical cutting programs to the USB drive. The controller supports parameter backup and restoration.
  • Cleaning: Keep the controller's screen and chassis clean. Use a soft, dry cloth. Avoid abrasive cleaners or solvents.
  • Environmental Control: Ensure the operating environment adheres to the specified temperature (-10°C to +60°C) and humidity (0-95% non-condensing) ranges.
  • Connection Checks: Periodically inspect all cable connections for tightness and signs of wear.
Visual representation of the U disk upgrade method and laser point offset feature.
Figure 8: U disk upgrade method illustration.

Troubleshooting

This section provides solutions to common issues. For problems not listed here, please contact technical support.

Problem Possible Cause Solution
Controller does not power on. No power supply or incorrect voltage. Verify DC 24V power supply connection and ensure power is greater than 80W. Check power cable integrity.
Motor not responding. Incorrect motor wiring or faulty motor. Check DB15 motor drive interface connections against pinout diagram (Figure 3). Test motor independently if possible.
Cutting program not loading from USB. USB drive format issue or file corruption. Ensure USB drive is formatted correctly and contains valid cutting codes. Try a different USB drive.
Inaccurate cutting. Incorrect parameters or mechanical issues with gantry. Review cutting parameters. Check mechanical components of the gantry for play or misalignment. Ensure control accuracy of ±0.001mm is maintained.
System error message. Software glitch or hardware malfunction. Restart the controller. If the error persists, perform a parameter restoration from backup. If still unresolved, contact support.

Important Safety Note:

Do not open the controller chassis within 5 minutes of powering off, as residual charge may be present. Always ensure the unit is properly grounded.

User Tips

  • Regular Backups: Always back up your system parameters and critical cutting programs to the USB drive. This can save significant time in case of unexpected data loss.
  • Optimize Cutting Parameters: Experiment with different cutting parameters for various materials and thicknesses to achieve the best cut quality and efficiency. The automatic speed limitation at corners is particularly useful for thicker plates.
  • Utilize Graphic Libraries: For common shapes, leverage the built-in 48 standard graphic libraries to quickly set up cutting tasks without needing to import new G-code.
  • Keep Software Updated: Take advantage of the lifetime U disk upgrade service to ensure your controller always has the latest features and performance improvements.
  • Grounding is Key: Ensure your entire cutting system, including the controller, is properly grounded to minimize electrical noise and enhance system stability.

Warranty and Support

This product is covered by a manufacturer's warranty against defects in materials and workmanship. For specific warranty terms, duration, and to obtain technical support or service, please refer to the documentation provided at the time of purchase or contact your vendor. Do not attempt to repair the unit yourself, as this may void the warranty. Always ensure to follow the warning "Do not open without warranty" as indicated on the device.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.